|
COMMERCE BUSINESS DAILY ISSUE OF JANUARY 28,2000 PSA#2525Bid Office, SPAWARSYSCEN, Code D21B, 53570 Silvergate Avenue, Bldg.
A33, Room 0061, San Diego, CA 92152-5112 58 -- AIRBORNE PARTICLE MONITOR SYSTEM SOL N66001-00-Q-1754 DUE 021400
POC Purchasing Agent, Claudia A. Aguzar, D211, (619) 553-6330.
Contracting Officer, Sylvia Proffit, D211, (619) 553-3292 Description:
This is a combined synopsis/solicitation prepared in accordance with
the format in the Federal Acquisition Regulation, supplemented with
information included in this notice. This solicitation incorporates
provisions and clauses at FAR 52.213-4 Terms and Conditions --
Simplified Acquisitions (Other Than Commercial Items) (FEB 1998), and
any others that are applicable and in effect through the current
Federal Acquisition Circular (FAC) and the Defense Acquisition
Circular. It is the contractors responsibility to be familiar with all
applicable clauses and provisions. No RFQ will be prepared or made
available for distribution. While price will be a significant factor in
the evaluation of offers, award will be based on responsive,
responsible, technically acceptable offers received in response to this
CBD advertisement.. Competitive awards may be based on the evaluation
criteria stipulated in the Red, Yellow, Green (RYG) Contractor
Evaluation System. The evaluation criteria is available upon request.
Specifications are as follows: 1. For use in a better than 100 class
cleanroom environment used for Silicon CMOS LSI IC fabrication; 2.
System must consist of 13 remote sensors that must connect
electronically to a main signal processing unit. This cannot be a
single sensing unit drawing samples through tubing from remote
locations; 3. System must work with available house vacuum of 20 inches
of Hg max; 4. Sensors must detect particles of 0.3 microns to 0.5
microns in size and work at a rate of 1.0 CFM; 5. Remote sensors must
have displays indicating proper/improper functional state; 6. System
must work on standard AC. Remote sensors must be powered through
connection to signal processing unit; 7. Remote sensor enclosure must
be no bigger than a maximum volume of 5 in by 5 in by 3 in and be
composed of cleanroom compatible material; 8. Four remote relative
humidity and temperature combination sensors must be included in
system. 8.1 Must measure 0-100% humididy and -20 to 80 C, 8.2 Each
sensor unit be smaller than 4 in x 4 in x 4 in dimension and cleanroom
compatible, 8.3 Power supplied by signal processing unit; 9. Signal
processing unit must receive analog inputs from four relative humidity
and temperature sensors as well as the input from remote sensors; 10.
Main processor units must have an RS-232 interface for connection to
a computer which runs the system management software; 11. System must
include a system management software package which runs on a Microsoft
Windows 95/98/ or NT operating system and which performs a minimum set
of tasks which include: 11.1 Real time display of the operational
status of all individual sensors and signal processing units including
alarms, flows, and particle size distinction, 11.2 Storage of data
acquired from sensors in a transportable format for import minimally
into Microsoft Access or Microsoft Excel, 11.3 Configurability of
system parameters for data acquisition and monitoring such as cycle
times; 12. Remote sensors and analog inputs must function at distances
greater than 100 feet away from signal processing unit; 13. 1500 feet
of cabling to connect remote sensors and analog inputs to main signal
processing unit included; 14. Sensor sampling input must work with 18
inch sensor tubing or similar for possible through-the-wall operation;
15. Price must include full service or warranty extension of at least
three years including on site calibration, parts and labor; 16. Price
must include installation with the possible exception of running cable.
Interested parties are invited to respond to this synopsis. No RFQ is
Available. Facsimile quotations are acceptable and must be received on
or before the COB on the closing date stated above. Facsimile
quotations may be sent to (619)553-4842. Questions may be directed to
the Purchasing Agent responsible for this action or email buyer at
aguzar@spawar.navy.mil. The applicable Standard Industrial Code (SIC)
and Size Standard is: 3663/18.0. Posted 01/26/00 (W-SN419281). (0026) Loren Data Corp. http://www.ld.com (SYN# 0146 20000128\58-0001.SOL)
58 - Communication, Detection and Coherent Radiation Equipment Index Page
|
|