COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 1,2000 PSA#2527Commercial Acquisition Department, Bldg 11, Naval Undersea Warfare
Center Division, Newport, Code 59, Simonpietri Dr., Newport, RI
02841-1708 70 -- MODIFICATION TO SYNOPSIS 002013 SOL N66604-00-Q-2013 DUE 020300
POC J. Clermont, Contract Negotiator at (401) 832-1460; K. Hughes,
Contracting Officer at (401) 832-1550; Fax at (401) 832-4820 WEB: Naval
Undersea Warfare Center Division, Newport,
http://www.npt.nuwc.navy.mil/contract/. E-MAIL: Jeannie Clermont,
Contract Negotiator, clermontjm@npt.nuwc.navy.mil. Synopsis
N66604-00-Q-2013 is modified as follows: Additional information on
desired characteristics follows: QUESTION: THE POWER SUPPLIES ARE
LISTED AS REDUNDANT. DOES THIS MEAN TWO SUPPLY'S PARALLEL TO EACH OTHER
(ONE TO OPEATE THE 21 SLOT VME64XTN BOARD, AND ONE TO OPERATE THE 21
SLOT REAR POSITION/SUBRACK VME BACKPLANE, (I'M ASSUMING THERE IS A 21
SLOT 6/U VME BACKPLANE BOARD, AS WELL) OR SHOULD THEY BE CURRENT
SHARING WITH "ORING" DIODE CONNECTIONS, IN WHICH CASE, WHEN ONE FAILS
(N+1) THE OTHER WILL CARRY THE FULL LOAD? ANSWER: The power supplies
units (PSU) are true redundant with power load sharing capability. In
the event one PSU fails, the alternate unit delivers power to all
voltages. QUESTION: (I'M ASSUMING THERE IS A 21 SLOT 6/U VME BACKPLANE
BOARD, AS WELL)? ANSWER: The rear backplane is a direct feedthrough of
the user defined pins of the P2 and power supply pins of the P1 and P2
to the front backplane. QUESTION: THE 1000 WATT POWER SUPPLY AS CALLED
OUT DOES NOT REFERENCE THE # OF OUTPUTS REQUIRED, NOR DOES IT IDENTIFY
THE INDIVIDUAL OUTPUT RATINGS. WHAT ARE THE OUTPUT RATINGS? ANSWER: A
single PSU delivers +5V @ 150A, +12V @ 20A (30A peak), additional +12V
@ 10A, -12V @ 10A. QUESTION: THE LCD IS ALSO VAGUE. WHAT SIZE
(MECHANICAL PARAMETERS), IS IT BLACK AND WHITE OR COLOR, HOW MANY
CHARACTERS PER LINE MUST IT PROVIDE, AND WHERE IS IT MOUNTED (THE UNIT
REQUIRES A PLEXIGLASS FRONT PANEL, SIZE OF WHICH IS DERIVED FROM THE
SIZE OF THE LCD DISPLAY). ANSWER: Greyscale LCD display with 128x240
dot array, or 16 rows X 40 columns of characters (utilizing 5x7
character font in 6x8 character cell). Physical dimensions of LCD
display are 170 x 105 mm mounted on front of chassis and clearly
viewable. Plexiglass front panel to cover front card slot region. Our
department no longer issues solicitations or amendments in paper form.
Instead, they may be accessed at our web site
http://www.npt.nuwc.navy.mil/contract/. We also provide electronic
access in our Bid Room. SIC Code: 3679 Posted 01/28/00 (W-SN419794).
(0028) Loren Data Corp. http://www.ld.com (SYN# 0268 20000201\70-0008.SOL)
70 - General Purpose ADP Equipment Software, Supplies and Support Eq. Index Page
|
|