COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 4,2000 PSA#2530Crane Division, Code 1165, Naval Surface Warfare Center, 300 Highway
361, Crane, IN 47522-5001 59 -- TANK, HIGH VOLTAGE SOL N00164-00-Q-0095 DUE 021500 POC Ms. Pat
Sturgis, Code 1165Z1, 812-854-1826, FAX 812-854-1841; Mr. Richard G.
Colvin, Code 1163ZR, Contracting Officer This is a combined
synopsis/solicitation for commercial items prepared in accordance with
the format in FAR Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation and is reserved for small business 52.219-6
[Standard Industrial Classification Code (SIC): 3795; Size: <=1,000
employees]; proposals are being requested and a written solicitation
will not be issued. Solicitation Number N00164-00-Q-0095 is issued as
a Request for Quotation. Solicitation document and incorporated
provisions and clauses are those in effect through Federal Acquisition
Circular 97-14 and Defense Acquisition Circular 91-13. The following
is a list of the requirements: Line Item 0001: Qty. Three (3) each
TANK, HIGH VOLTAGE, STANGENES P/N SI-12896 OR EQUAL in accordance with
the following specifications: The equipment shall consist of 1. AC
input voltage: 480 VAC, 3 phase, 60 Hz, MAX. 560 VAC. 2. Output DC
voltage: 19 KVDC, 3. Output current: 1 Amp avg., 4. Cooling: Convention
in oil, 5. Rectifier Assembly: shall be 3 phase full wave bridge, 6.
Bleeder Resistor: shall be 10 M Ohms across the 4 uf cap, 7. Output
Cap: shall be 4 uf at 30 KV, 8. Transformer: Impedance: 7 % MIN.,
Regulation: 3 % MAX., Shields: Primary shall have an electrostatic
shield tied to the core. The primary surge shall be tied to a low
voltage reference. Isolation: the primary electrostatic shield shall be
5 kv RMS., Secondary to primary, core, SH1 and SH2 shall be 30 kv.,
Terminals: B+ and B- terminals shall be isolated from gnd by a minimum
of 25kv. Primary terminals shall be .25 inch -- 20 posts. Secondary
terminals shall be 8-32 tapped posts. Shield terminals shall be .25
inch -- 20 posts. Life: Design to a life expectancy of 100,000 hrs. or
20 years. Full 1-year warranty required. 9. Oil tank: Tank shall have
360 degree casters. All components will be mounted to the top of the
tank. Tank shall be hermetically sealed to prevent oil leakage. Eye
bolts shall be provided on lid, at four corners to lift lid as
necessary. Tank shall have pressure relief valve. Tank shall have drain
plug, and fill plug. Tank Dimensions shall be as follows: height: 43.5"
+/- 1", Length: 30.5" +/- 1", Width: 32.0" +/- 1"., Tank color:
Standard Stangenes blue or similar. All HV output terminals and 480
terminals will be on the lid of the supply. All terminals will be
clearly marked B+, B-, A,B,C, (B. C. ) and gnd. Delivery shall be
f.o.b. destination, Naval Surface Warfare Center, Crane, IN, with the
inspection/acceptance at destination. Delivery will be required within
70 days from contract award. FAR Clauses/Provisions 52.203-3
Gratuities, 52.212-1 Instructions to offerors -- Commercial Items,
52.212-4 Contract Terms and Conditions -- Commercial Items, 52.212-5
Contract Terms and Conditions Required to Implement Statutes or
Executive Orders -- Commercial Items (incorporating FAR 52.222-35
Affirmative Action for Special Disabled and Vietnam Era Veterans,
52.222-36 Affirmative Action for Handicapped Workers, 52.222-37
Employment Reports on Special Disabled Veterans and Veterans of the
Vietnam Era, 52.225-3 Buy American Act-Supplies, 52.225-21 Buy American
Act-North American Free Trade Agreement Implementation Act-Balance of
Payments Program), 52.219-14 Limitation on Subcontracting, DFARS Clause
252.227-7015 Technical Data -- Commercial Items apply to this
acquisition. The contractor shall extend to the Government the full
coverage of a 1-year standard commercial warranty, provided such
warranty is available at no additional cost to the Government. Offerors
responding to this announcement must provide the information contained
in 52.212-1, Instruction to Offerors -- Commercial Items and must
include a completed copy of provision 52.212-3, Offeror Representations
and Certifications -- Commercial Items. The offeror is required to
register on-line in the Central Contractor Registry (CCR) at
http://www.ccr2000.com/ DFARS clause 204.7303 Procedures. The offeror
should also provide its Commercialand Government Entity (CAGE) code,
Contractor Establishment code (DUNS Number) and Tax Identification
Number. If a change occurs in this requirement, only those offerors
that respond to this announcement within the required time frame will
be provided any changes/amendments and considered for future
discussions and/or award. The written quotes and the above required
information must be received at this office on or before 02/15/00 at
2:00 PM. Eastern Std. Time. Point of contact for information regarding
this requirement is Ms. Pat Sturgis, 812-854-1826, FAX 812-854-1841,
or e-mail sturgis_p@crane.navy.mil. All responsible sources may submit
a quote which will be considered by the agency. Posted 02/02/00
(W-SN420872). (0033) Loren Data Corp. http://www.ld.com (SYN# 0228 20000204\59-0008.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|