Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 4,2000 PSA#2530

Crane Division, Code 1165, Naval Surface Warfare Center, 300 Highway 361, Crane, IN 47522-5001

59 -- TANK, HIGH VOLTAGE SOL N00164-00-Q-0095 DUE 021500 POC Ms. Pat Sturgis, Code 1165Z1, 812-854-1826, FAX 812-854-1841; Mr. Richard G. Colvin, Code 1163ZR, Contracting Officer This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation and is reserved for small business 52.219-6 [Standard Industrial Classification Code (SIC): 3795; Size: <=1,000 employees]; proposals are being requested and a written solicitation will not be issued. Solicitation Number N00164-00-Q-0095 is issued as a Request for Quotation. Solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-14 and Defense Acquisition Circular 91-13. The following is a list of the requirements: Line Item 0001: Qty. Three (3) each TANK, HIGH VOLTAGE, STANGENES P/N SI-12896 OR EQUAL in accordance with the following specifications: The equipment shall consist of 1. AC input voltage: 480 VAC, 3 phase, 60 Hz, MAX. 560 VAC. 2. Output DC voltage: 19 KVDC, 3. Output current: 1 Amp avg., 4. Cooling: Convention in oil, 5. Rectifier Assembly: shall be 3 phase full wave bridge, 6. Bleeder Resistor: shall be 10 M Ohms across the 4 uf cap, 7. Output Cap: shall be 4 uf at 30 KV, 8. Transformer: Impedance: 7 % MIN., Regulation: 3 % MAX., Shields: Primary shall have an electrostatic shield tied to the core. The primary surge shall be tied to a low voltage reference. Isolation: the primary electrostatic shield shall be 5 kv RMS., Secondary to primary, core, SH1 and SH2 shall be 30 kv., Terminals: B+ and B- terminals shall be isolated from gnd by a minimum of 25kv. Primary terminals shall be .25 inch -- 20 posts. Secondary terminals shall be 8-32 tapped posts. Shield terminals shall be .25 inch -- 20 posts. Life: Design to a life expectancy of 100,000 hrs. or 20 years. Full 1-year warranty required. 9. Oil tank: Tank shall have 360 degree casters. All components will be mounted to the top of the tank. Tank shall be hermetically sealed to prevent oil leakage. Eye bolts shall be provided on lid, at four corners to lift lid as necessary. Tank shall have pressure relief valve. Tank shall have drain plug, and fill plug. Tank Dimensions shall be as follows: height: 43.5" +/- 1", Length: 30.5" +/- 1", Width: 32.0" +/- 1"., Tank color: Standard Stangenes blue or similar. All HV output terminals and 480 terminals will be on the lid of the supply. All terminals will be clearly marked B+, B-, A,B,C, (B. C. ) and gnd. Delivery shall be f.o.b. destination, Naval Surface Warfare Center, Crane, IN, with the inspection/acceptance at destination. Delivery will be required within 70 days from contract award. FAR Clauses/Provisions 52.203-3 Gratuities, 52.212-1 Instructions to offerors -- Commercial Items, 52.212-4 Contract Terms and Conditions -- Commercial Items, 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items (incorporating FAR 52.222-35 Affirmative Action for Special Disabled and Vietnam Era Veterans, 52.222-36 Affirmative Action for Handicapped Workers, 52.222-37 Employment Reports on Special Disabled Veterans and Veterans of the Vietnam Era, 52.225-3 Buy American Act-Supplies, 52.225-21 Buy American Act-North American Free Trade Agreement Implementation Act-Balance of Payments Program), 52.219-14 Limitation on Subcontracting, DFARS Clause 252.227-7015 Technical Data -- Commercial Items apply to this acquisition. The contractor shall extend to the Government the full coverage of a 1-year standard commercial warranty, provided such warranty is available at no additional cost to the Government. Offerors responding to this announcement must provide the information contained in 52.212-1, Instruction to Offerors -- Commercial Items and must include a completed copy of provision 52.212-3, Offeror Representations and Certifications -- Commercial Items. The offeror is required to register on-line in the Central Contractor Registry (CCR) at http://www.ccr2000.com/ DFARS clause 204.7303 Procedures. The offeror should also provide its Commercialand Government Entity (CAGE) code, Contractor Establishment code (DUNS Number) and Tax Identification Number. If a change occurs in this requirement, only those offerors that respond to this announcement within the required time frame will be provided any changes/amendments and considered for future discussions and/or award. The written quotes and the above required information must be received at this office on or before 02/15/00 at 2:00 PM. Eastern Std. Time. Point of contact for information regarding this requirement is Ms. Pat Sturgis, 812-854-1826, FAX 812-854-1841, or e-mail sturgis_p@crane.navy.mil. All responsible sources may submit a quote which will be considered by the agency. Posted 02/02/00 (W-SN420872). (0033)

Loren Data Corp. http://www.ld.com (SYN# 0228 20000204\59-0008.SOL)


59 - Electrical and Electronic Equipment Components Index Page