COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 17,2000 PSA#2539National Institutes of Health, National Heart, Lung, and Blood
Institute, Contracts Operations Branch, 6701 Rockledge Drive, Room
6100, MSC 7902, Bethesda, MD 20892 66 -- INSTRUMENT AND LABORATORY EQUIPMENT SOL NHLBI-PS-2000-572 DUE
030100 POC Tabitha Davol, Purchasing Agent, (301) 435-0368 Fax # (301)
480 -- 3345 The National Heart, Lung, and Blood Institute intends to
purchase the specific make /model (brand name) items listed below from;
DATA SCIENCES, SUITE 2244, 4211 LEXINGTON AVE N., ST. PAUL, MN 55126.
ITEM#1. Thirteen (13) each, catalog No. 270-0040-015, TA11PA-C40 with
15 cm long catheter, Pressure and physical activity, Nominal Battery
Life: 6 mo. (Warranted 4 Mo.), Recommended implant Duration; 9mo.
Magnetic on/off awitch. Typical cage size; 42x42x25cm. Item#2. Seven
(7) each, catalog No.7272-6001-001, RPC-1, General Purpose Receiver for
Plastic Cages. ITEM#3. One (1) each, catalog No. 271-0117-001, DEM,
Dataquest ART Data Exchange Matrix w/4m Cable. ITEM#4. One (1) each,
catalog No. 370-0102-001, Power Supply, Power Supply for Art (for both
110v & 220v). Item#5. One (1) each, catalog No. 274-0009-001, USA,
Canada, Japan, power cord to IDE for 110V Power Supply No charge with
the purchase of an ART Power Supply. Item#6. One (1) each, catalog No.
276-0023-001, Regel Syringe, Re-gel Syringe filled with .25cc gel,
enough for 50 transmitters. Item#7. One (1) each, catalog No.
370-0034-001, Magnet. Item#8. One (1) each, catalog No. 271-0116-004,
DQ A.R.T. Gold, Dataquest Acquisition & Analysis System ART Includes
Computer, Monitor, Software, Board, and 4m cable. This is an integrated
system for measuring blood pressure in unrestrained, untethered, awake
rats and mice; all the parts are specially designed to work together.
The individual components are proprietary products designed to work as
a single system. The device is a specially designed blood pressure
sensor coupled in specially-designed circuitry with a radio transmitter
that is surgically implanted in a mouse or rat. The blood pressure
information is sent out of the animal as a radio signal that is picked
up by a specially designed antenna and relayed to special circuitry
that translate the signal into blood pressure readings with the use of
a special computer program running on a unique platform. This
acquisition is conducted under simplified acquisition procedures. The
Standard Industrial Classification (SIC) Code 3826, Size Standard is
500. The following Federal Acquisition Regulation (FAR) clauses apply
to this requirement. FAR Clause 52.212-1 INSTRUCTION TO
OFFERORS-COMMERCIAL ITEMS (NOV 1999), FAR Clause 52.212-2, EVALUATION-
COMMERCIAL ITEMS (JAN 1999), FAR Clause 52212-3, OFFEROR
REPRESENTATIONS AND CERTIFICATIONS-COMMERCIAL ITEMS (OCT 1999), FAR
Clause 52.212-4, CONTRACT TERMS AND CONDITIONS-COMMERCIAL ITEMS (MAY
1999), AND FAR Clause 52.212-5, CONTRACT TERMS AND CONDITIONS REQUIRED
TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS -- COMMERCIAL ITEMS (MAY
1999). The clauses are available in full text at
http://www.arnet.gov/far/. This notice of intent is not a request for
competitive proposals. Interested parties may identify their interest
and capabilities in response to this requirement. The determination by
the government not to compete the proposed contract based upon
responses to this notice is solely for the purpose of determining
whether to conduct future competitive procurement. Responses to this
announcement, referencing synopsis number NHLBI-PS-2000-572 may be
submitted to the National Heart, Lund, and Blood Institute, Contracts
Operations Branch, Procurement Section, Building RKL2, Room 6145,6701
Rockledge Drive, Bethesda MD 20892-79,. Attention Tabitha Davol,
Purchasing Agent. All responsible sources may submit a quotation, which
if timely received, shall be considered by the agency. Posted 02/15/00
(W-SN425598). (0046) Loren Data Corp. http://www.ld.com (SYN# 0266 20000217\66-0002.SOL)