Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 24,2000 PSA#2543

SA-ALC/Contracting Directorate/LDKAA; 485 Quentin Roosevelt Road Suite 12; Kelly AFB, TX 78241-6419

66 -- CALIBRATION SET SOL F41608-00-R-31643 DUE 040700 POC The Point of Contact is Ron Du Pree, LDKAA, Phone: (2100 925-8461, FAX: (2100 925-2098, E-MAIL: ronald.dupree@kelly.af.mil E-MAIL: Send your E-Mail request to the POC, ronald.dupree@kelly.af.mil. The has Air Force has a requirement for the following: CLIN 0001: Calibrator Set, 1 EA=20 6695-01-461-0250 =20 P/N: P/N: FDI-SGFC-0250 SIZE: =20 FORM, FIT, FUNCTION: The SGFC is a completely=20 automated calibration transfer standard system,=20 designed for calibration of gas flow meters. It utilizes sonic nozzles, temp., and pressure transducers,=20 Pneumatic Control Valves, and a personal computer to Set, Monitor and control calibrator flow rate. Shipment of the items are destined for: Warner Robbins Air Force Base, Georgia. PREDOM MATERIAL: Electronic components. APPL: ESS Common Age P/R Nr: FD2050-00-29547 SPECIFICATIONS: Flow range: 0.0105 SCFM to 250=20 SCFM; Operating fluid types: Air Nitrogen; Compensated=20 fluid types; Helium, Oxygen, Carbon Dioxide; Operating=20 Temperature Range: Flowing gas stream, 60-90 deg F=20 Electronics/Transducers environment: 70 deg Porm=20 20 deg F; Outputs: communications, RS-232C or=20 IEEE 488; Display 20 character X2 line; Accuracy: Porm 0.35% Reading @ 1 standard deviation. Power Requirements: 115 vac/60 Hz/2Amp; air Supply: 120=20 psia regulated source 250 SCFM=20 Government=92s Required delivery; 30 Dec 2000 The Air Force intends to award to a source contractor, Flow Dynamics, Inc, CAGE: 0U3B5 This is a non competitive COMMERCIAL-OFF-THE- SHELF (COTS) item purchase. There are no Government Drawings or specifications=20 Available for this solicitation. This is not a small business=20 set-aside. The Government anticipates releasing a paper=20 Request for Proposal (RFP) on or about 7 Mar 2000 to=20 source(s)requesting a RFP document. Fax requests to the=20 point of contact (POC) are allowed and should be requested=20 in time to meet the RFP response date. CBD Notes 22=20 and 26 are applicable. =20 All potential offerors should contact the buyer/PCO identified in this notice for additional information and/or to communicate concerns, if any,=20 concerning this acquisition. If your concerns are not satisfied by the contracting officer, an Ombudsman has been appointed to hear concerns from offerors or potential offerors during the proposal development phase of an acquisition. The Ombudsman does not diminish the authority of the program director or Contracting Officer, but communicates Contractor concerns, issues, disagreements, and recommendations to the appropriate Government personnel. When requested, the Ombudsman shall maintain strict confidentially as to the source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call the SA-ALC Acquisition Ombudsman at AC 210-925-5133 or send E-Mail to: ombudsman@www.kelly-afb.org.=20 See Note(s) 22,26,26 Posted 02/22/00 (D-SN427334). (0053)

Loren Data Corp. http://www.ld.com (SYN# 0206 20000224\66-0001.SOL)


66 - Instruments and Laboratory Equipment Index Page