COMMERCE BUSINESS DAILY ISSUE OF MARCH 14,2000 PSA#2556USAED, Sacramento, Corps of Engineers, Contracting Division, 1325 J
Street, Sacramento, CA 95814-2922 48 -- MANUFACTURE OF TURBINE BYPASS VALVE, PINE FLAT LAKE SOL
DACW05-00-R-0016 DUE 050400 POC Beverly Hatfield (916)557-5232 PLEASE
BE SURE TO PROVIDE A VALID E-MAIL ADDRESS WHEN FILLING OUT ORDERING
INFO ON OUR WEBSITE FOR ADDING YOUR NAME TO THE PLAN HOLDERS LIST. NOTE
THAT FAILURE TO FILL IN A VALID E-MAIL ADDRESS COULD RESULT IN YOU NOT
OBTAINING AMENDMENTS PUT OUT AGAINST THE SOLICITATION YOU ARE
ORDERING, AS WE ARE ONLY SENDING OUT AMENDMENTS TO SOLICITATIONS VIA
ELECTRONIC MAIL NOW. PROJECT TITLE: Turbine Bypass Valve. This proposed
contract is UNRESTRICTED. JOB DESCRIPTION: Requirement is described as
follows: Manufacturer shall provide two energy dissipating, free
discharge, regulating valves, or either the sleeve or plate type
multijet design. Each valve shall be delivered to Pine Flat Dam
(located approx. 30 miles east of Fresno, California). The manufacturer
shall be responsible for design, fabrication, shop testing,
transportation, and performance testing. One valve will be connected to
a 66-inch pipe flange and the other to a 48-inch pipe flange. The
valves shall be capable of producing a combined flow of at least
750-CFS of water (temperature range of 32 to 80 deg F) when subjected
to a static head of 128.55 feet for the 48-inch valve and 118.25 feet
for the 66-inch valve. Each valve shall also be capable of producing a
minimum flow 50-CFS or less at these head conditions. Finally, the
valves shall be capable of producing a combined flow of at least
900-CFS when subjected to a static head of 365.05 feet for the 48-inch
valve and 354.75 feet for the 66-inch valve. The upstream static heads
do not include head losses in the upstream system. The net head on the
valves should be computed as the static head minus the upstream head
losses. The upstream head losses can be computed as k multiplied times
the pipe velocity head. For the 48 inch pipe, k=0.26 and the
corresponding velocity head is the velocity head in the 48 inch pipe.
For the 66 inch pipe, k=1.55 and the corresponding velocity head is the
velocity head in the 66 inch pipe. Both pipelines will have a minimum
of 5 diameters of straight piping immediately upstream of the valves.
Valves shall be capable of throttling all flows satisfactorily without
cavitation at the design pressure, shall be rated for a static
pressure of 175 psi, shall be equipped with ANSI flanges or with
retaining flanges and flange seals if the valves are wafer type, and
shall include electric (460/230 volt, 3 phase power) or hydraulic
operators and all appurtenances required for local push button
operation. The operators shall be sized for a minimum of 1.5 times the
maximum force required to actuate the valves. The manufacturer shall
provide a five (5) year guarantee that the valves will perform
satisfactorily under actual operating conditions. The manufacturer
shall have a minimum of ten (10) years' experience in the design and
construction of similar valves, which can be demonstrated to have
operated successfully. SIC CODE: This procurement will be conducted
under SIC CODE 3491. The size standard for this SIC Code is:
$17,000,000.00. REQUEST FOR PROPOSAL: The acquisition method is
negotiatedProcurement. A technical and cost proposal will be required.
Evaluation by the Government will result in selection of a firm that
represents the best value to the Government. For more information of
the solicitation please contact the Contract Specialist, Beverly
Hatfield, at 916-557-5232. ORDERING PLANS AND SPECIFICATIONS:
(AVAILABLE ON PAPER COPY; FREE OF CHARGE) Plans and specifications for
this project must be ordered by the CUT OFF DATE of 04/04/2000 to
ensure receipt of bid sets. Plans and specifications can only be
ordered electronically by accessing internet address
http://ebs.spk.usace.army.mil/ Please complete the requested
information to avoid a delay in your order. Orders received beyond the
CUT OFF DATE of 04/04/2000 will not be honored. Plans and
specifications will be mailed out on or about 04/10/2000. Because a
limited number of sets will be reproduced, copies are limited to one
set per firm. All responsible sources may submit a bid or proposal
which will be considered by the agency. See Note26 (See Commerce
Business Daily, Monday edition). For a listing of all Sacramento
District projects, see Contracting Division's Internet Home Page at
http://ebs.spk.usace.army.mil/ which is updated daily. Please note that
all contractors and potential contractors must be registered with the
Central Contractor Registration (CCR) database effective May 31, 1998.
For instruction on registration with the CCR please see our webpage.
Posted 03/10/00 (W-SN433286). (0070) Loren Data Corp. http://www.ld.com (SYN# 0190 20000314\48-0004.SOL)