Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MARCH 14,2000 PSA#2556

General Services Administration, Public Buildings Service (PBS), Property Development Division (1PC), 10 Causeway Street, Boston, MA, 02222-1077

C -- A/E DESIGN SERVICES GIAIMO U.S. FEDERAL BUILDING, NEW HAVEN, CT SOL GS-01P-00-BZC-0003 DUE 041700 POC Peter Menzies, Contracting Officer, Phone (617) 565-5733, Fax (617) 565-5967, Email peter.menzies@gsa.gov -- Peter Menzies, Contracting Officer, Phone (617) 565-5733, Fax (617) 565-5967, Email peter.menzies@gsa.gov WEB: Visit this URL for the latest information about this, http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=GS-01P-00-BZC-0003&LocID=258. E-MAIL: Peter Menzies, peter.menzies@gsa.gov. Document Type: Presolicitation Notice Solicitation Number: GS-01P-00-BZC-0003 Posted Date: March 10, 2000 Response Date: April 17, 2000 Classification Code: C -- Architect and engineering services Contracting Office Address General Services Administration, Public Buildings Service (PBS), Property Development Division (1PC), 10 Causeway Street, Boston, MA 02222-1077 Attn: Peter J. Menzies, Contracting Officer Description The General Services Administration (GSA) is seeking Architect-Engineer (A-E) Design Services for the renovation and modernization of the 16,474 Square Meter Robert N. Giaimo Federal Building, New Haven, CT. The project will alter building fenestration and refurbish the exterior facade. It will upgrade accessibility to meet the requirements of the Americans with Disabilities Act (ADA). Structural upgrades shall be done for current seismic and wind load requirements. Additional components of the project include: alteration of egress balconies; renovation of all tenant areas, restrooms and elevator lobbies; correction of codes deficiencies; abatement of hazardous materials (asbestos containing materials and lead paint); upgrading of elevators; renovation of plaza area; upgrading of plumbing, fire protection, mechanical and electrical systems, and security. And any other design work deemed necessary to implement the concepts developed during previous renovation studies or that arise during the development of concept design. This project shall be designed in metric units. The construction contract will have a base contract for those elements of work that can be executed within the Congressionally mandated cost limitation, and contract options, alternates or line items for those elements of work that may be funded from other sources. The A-E firm as used in this solicitation may be a partnership, corporation, association or other entity that will have contractual responsibility for the project design. The A-E firm and all applicable consultants must be licensed to practice their specialty (architecture/engineering) in the State of Connecticut. The estimated construction cost of this project is over $10,000,000. The A/E fee for design services shall be within the 6% statutory limitation, based on the government construction estimate at the time of negotiation. Services required include, but are not limited to: planning phase feasibility studies, including construction phasing and swing space design, design programming, design, cost estimating/analyses, code review, value engineering management, post construction contract services (PCCS) (Option), record drawings on CAD, construction management, administration and inspections (Option), testing oversight and review, building turnover coordination, post occupancy evaluations and any other services deemed necessary to provide for a completely functional facility. The Government has determined that the following disciplines and/or consultants are required: Architectural, Civil, Structural, Mechanical, Electrical, Fire Protection and Life Safety, Hazard Materials, Lighting, Cost Estimating, Elevators, Roofing, Construction management and administration, testing and inspection services. Consideration is limited to firms having an active design/production office located within the New England Region, CT, MA, ME, NH, RI, VT. At least one member for the contract will be New England wide. The selected A-E must have a production office within the six New England states. The Evaluation Criteria for selection are as follows: (1) EXPERIENCE (25% weight factor): Past projects demonstrate creativity in applying innovative engineering design approaches, energy conservation, sustainable design principles (building green), and indicate an integrated HVAC design excellence strategy, demonstrate creativity in interior design. Projects have received awards/recognition for design excellence. Past projects are of office modernization and similar complexity and size. (2) TEAM_S PROFESSIONAL QUALIFICATIONS/EXPERIENCE (25% weight factor): Individual key persons have appropriate qualifications and experience to bring a level of excellence to all aspects of this project. Project team/consultants demonstrate an approach that endeavors to provide a well managed and coordinated design effort. Project Manager proposed has the leadership and experience to be responsive to the requirements of this project. (3) ORGANIZATION (25% weight factor): Firm_s ability to meet/work within constrictive time frames. Office production methods/technology, familiarity with metric document production. The proposed team has previous experience working together. The firm_s commitment to projects requirements/opportunities available for small, minority, and woman-owned businesses. The team indicates a clear commitment to perform a significant portion of the project_s design/construction documents in New England. The team proposed demonstrates an approach to project accomplishment that will effect an efficiently executed and well coordinated project. (4) QUALITY AND COST CONTROL (25% weight factor): Ability to evaluate/develop accurate preliminary project budgets; ability to control project costs during design process; methods used to coordinate construction documents, work of various engineering disciplines, and provide general production quality control. If selected for an interview, the A-E Firm shall be prepared to discuss all aspects of the Evaluation Criteria indicated above and to demonstrate the ability to fulfill all contract requirements. This procurement is being made under the Small Business Competitiveness Demonstration Program (FAR 19.10). Small, small disadvantaged and small woman-owned firms are strongly encouraged to participate. Large business firms are reminded that the successful firm will be expected to place subcontracts to the maximum practical extent with small, small disadvantaged and small woman-owned firms as part of their original submitted team. Before award of the contract, the A-E (if not a small business under SIC Code 1812) shall be required to present an acceptable Small Businessand Small Disadvantaged Business Subcontracting Plan in accordance with Public Law 95-507. As part of its commitment to socioeconomic initiatives of the Federal Government, the General Services Administration, Public Buildings Service has established for fiscal 2001 subcontracting goals of 40% for small businesses, 5% for small disadvantaged businesses and 5% for small woman-owned businesses. Firms having the capabilities to perform the services described in this announcement are invited to respond by submitting completed SF-254's (for firm, joint ventures, and consultants), which must be dated not more than twelve (12) months before the date of this synopsis, and a (ONE COPY) SF-255 along with letter of interest to: General Services Administration, New England Region, T.P. O_Neill Jr. Federal Building room #975, 10 Causeway Street Boston, MA 02222-1077, by DATE: 04/17/00, TIME: 3:00 PM local time. The following information MUST be on the outside of the sealed envelope: 1) Solicitation Number/Title, 2) Due Date, 3) Closing Time. Late responses are subject to FAR Provision 52.214-7. In Block 8 of the SF-254 specify only current W-2 payroll (non-contract) personnel of each firm. In Block 10 of the SF-255, the A-E Firm MUST respond to the FOUR (4) EVALUATED CRITERIA stated in the CBD announcement for this solicitation. In Block 11 of the SF-255, the A-E Firm MUST sign, (name and title) and date the submittal. Award of this contract is contingent upon funding approval. This contract is being procured under the Brooks Act and FAR 36. This is not a Request for Proposal. Point of Contact Peter J. Menzies, Contracting Officer, Phone (617) 565-5733, Fax (617) 565-5967, Email peter.menzies@gsa.gov Email your questions to Peter J. Menzies at peter.menzies@gsa.gov Posted 03/10/00 (D-SN433354). (0070)

Loren Data Corp. http://www.ld.com (SYN# 0018 20000314\C-0004.SOL)


C - Architect and Engineering Services - Construction Index Page