COMMERCE BUSINESS DAILY ISSUE OF MARCH 16,2000 PSA#2558National Institutes of Health, Office of Procurement Management, 6011
Executive Blvd., Rockville, Maryland 20892-7260 66 -- INSTRUMENTS & LABORATORY EQUIPMENT SOL 263-00-B-(GQ)-0018 DUE
040400 POC Dorothy Nickens, (301) 496-0301, Fax (301) 402-3407 Under
authority of U.S.C. 253(c) (1), FAR 6.302-1 the National Institutes of
Health (NIH), Bethesda, Maryland intends to negotiate on a sole source
basis, a contract with Carl Zeiss, Inc, One Zeiss Drive, Thornwood, NY
10594. The National Institutes of Health, National Institute of Aging
(NIA) in Baltimore, Maryland has a requirement for a real time digital
fluorescence analyzer system. This system shall include, but not be
limited to, the following performance characteristics, features, and
pertain to the following components: Shall perform analysis of
fluorescent probes in living cells and preparations. Shall be capable
of visualizing ions in real time. Ions shall be observable individually
or simultaneously, only the types of probes in use shall limit
combinations. Shall include image intensified CCD (ICCD) and high
resolution digital cameras. Shall include motorized inverted microscope
and confocal module. Shall provide for simultaneous fluorescence and
brightfield image acquisition. Shall include the capability for three
ratio images per second in dual excitation configuration with a
standard wavelength selector or better. Shall provide for ten ratios
per second in static ratio imaging mode or better. Shall include upper
and lower gray-value threshold functions. Shall provide for online
background correction, ratio display, and shading correction functions
or better. Shall provide for static ratio imaging and image averaging.
Full frame ratio imaging shall be supported. Shall include image
integration for very low light experimentation. Shall include
provisions for data calibration. Shall include automated and
interactive image storage. Shall include support for up to 99 regions
of interest or better. Shall include experimental log and timer. Shall
support stored image sequence analysis. Shall include software to
integrate data and images. Shall include Z focus control. Shall be
capable of performing ion studies in confocal mode in cells or tissues.
The system shall be capable of providing three-dimensional image stacks
of multiple probes. This shall allow for investigation of the structure
and co-localization of antibodies. Shall support non-laser confocal
fluorescence. Shall support ultraviolet and visible excitation
wavelengths. Shall include PC based software for controlling the
microscope hardware and digital imaging system. Shall include a
Personal Computer with the following features, or better: Windows 98
software, 450MHz Pentium III processor, 128 megabytes of RAM, Two 17
inch monitors, Read/Write CD-ROM drive, Zip drive, LAN capable. The
system shall be complete and perform the functions for which for which
it was intended. All necessary interconnection cabling, documentation,
and support after installation shall be provided. The system shall be
compatible with existing Carl Zeiss Inc. equipment that has been
previously acquired. The intended procurement will be classified under
the Standard Industrial Classification Code (SIC) 3826, Laboratory
Analytical Instruments with a size standard of 500 employees. Any
response must be received in writing within fifteen (15) business days
from the published date of this notice. Information furnished should
include enough material to allow the Agency to perform a proper
evaluation. Concerns that respond to this synopsis shall furnish
concise responses directed specifically to the requirement mentioned
above and are invited to submit capability statements in an original
plus two (2) copies no later than fifteen (15) business days from the
date of this announcement. Source demonstrating the capability to
accomplish the above shall supply pertinent information in sufficient
detail to demonstrate their ability to perform. Written response shall
include complete description of the services to be provided,
containing sufficient technical information to permit agency analysis
to establish a bona fide capability to meet the stated requirements as
listed above. This is not a request for proposal (RFP). Capability
Statement: (a) If mailing your response through the U.S.Postal Service,
use the following address: National Institutes of Health, Office of
Procurement Management, 6011 Executive Blvd., Room 529M, MSC 7663,
Attn.: Dorothy Nickens, Bethesda, Maryland 20892-7663; (b) If hand
delivering or using a courier services (e.g. Federal Express, UPS,
etc.,) use the following City, State and Zip code: Rockville, Md.
20852. Posted 03/14/00 (W-SN434162). (0074) Loren Data Corp. http://www.ld.com (SYN# 0221 20000316\66-0003.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|