|
COMMERCE BUSINESS DAILY ISSUE OF MARCH 20,2000 PSA#2560Dahlgren Division, Naval Surface Warfare Center, 17320 Dahlgren Road,
Dahlgren, VA 22448-5100 10 -- M8 SMOKE POTS (DODIC K511) SOL N00178-00-Q-1030 DUE 042400 POC
G. R. Vaughan, Contracting Officer, Code SD105, (540)653-7478 WEB:
NSWCDD Dahlgren Laboratory Procurement Division Web,
http://www.nswc.navy.mil/supply. E-MAIL: POC for N00178-00-Q-1030,
vaughangr@nswc.navy.mil. This synopsis is issued as a Request for
Information for sources capable of fulfilling the U. S. Marine Corps
requirement to replace the current M4A2 Smoke Pot, Floating (DODIC
K867) with a Smoke Pot containing non-toxic chemical and a new fuzing
system. This request is a market survey for information purposes only
and not a request for proposal or announcement of a solicitation. The
purpose of this market survey is to identify sources that may be
capable of upgrading/replacing the current system with a non-toxic
chemical and new fuzing system, while maintaining or improving the
performance of the existing system. A proposed system that would result
in any performance degradation will be unacceptable. The M4A2 Smoke Pot
is a five-gallon metal pail with its lower third filled with
approximately 25 pounds of type C HC smoke mixture and fuzed with an
M207A1 floating smoke pot fuze. The M207A1 fuze is a pyrotechnic,
delay-igniting fuze. Before the M4A2 smoke pot can be employed, the
ring clamp and outer cover must be removed. The M207A1 fuze safety
lever is held against the fuze body and the safety pin withdrawn by
pulling the pull ring. The pot is lifted by its handle and dropped into
the water. The air chamber in the pot causes it to float. When the fuze
safety lever is released, the striker spring drives the striker, which
hits the primer. The primer ignites the first-fire charge, which, in
turn, ignites the delay charge. After about two seconds, the delay
charge ignites the ignition charge thus completing the fuze action.
Flame from the ignition charge travels through the pot's igniter tube
to ignite the starter mixture, which then ignites the HC smoke mixture
filling. Pressure from the heat builds up inside the pot and blows off
the adhesive tape covering the vents in the inner cover. Smoke
particles escape through the vents to form a dense, white smoke cloud.
Interested parties should submit their responses (3 copies) no later
than 24 April 2000. Information submitted in this statement should
include organization name, a brief description of the technology and
its current status, and a point if contact. Mail responses to
Contracting Officer, Attn: Code SD105, Building 183, first floor, Room
133, NAVSURFWARCEN, Dahlgren Division, 17320 Dahlgren Road, Dahlgren,
Virginia 22448-5100. The submission should reference N00178-00-Q-1030.
This information is for reference and planning only, and the Government
will not pay for any information submitted or for cost associated with
providing this information. Proprietary responses will be protected in
accordance with the markings. The Naval Surface Warfare, Dahlgren
Division, Dahlgren Procurement Division has implemented Electronic
Commerce (EC) in the acquisition area, therefore, any information
regarding this RFI with any applicable amendments will be available on
the World Wide Web at http://www.nswc.navy.mil/supply. Hard copies
will not be provided. Vendors should regularly access the NSWCDD Web
Site to ensure that they have downloaded all amendments. Posted
03/16/00 (W-SN435050). (0076) Loren Data Corp. http://www.ld.com (SYN# 0148 20000320\10-0003.SOL)
10 - Weapons Index Page
|
|