COMMERCE BUSINESS DAILY ISSUE OF MARCH 23,2000 PSA#2563Department of the Air Force, Air Force Space Command, 30CONS, Bldg
7015, STE 2D, 806 13th Street, Vandenberg AFB, CA, 93437-5226 44 -- REPLACE HOT WATER BOILER @ BLDG 21200 SOL F04684-00-T-0517 DUE
041000 POC Robert Taylor, Contract Specialist, Phone (805) 605-3933,
Fax (805) 606-4863, Email robert.m.taylor@vandenberg.af.mil -- Betty
Rosewaren, Contracting Officer, Phone COMM: 805.605.8470, Fax
805-922-1703, Email WEB: Visit this URL for the latest information
about this,
http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=F04684-00-T-0
517&LocID=528. E-MAIL: Robert Taylor,
robert.m.taylor@vandenberg.af.mil. The 30th Space Wing, Vandenberg AFB,
CA 93437-5226 is soliciting offerors to replace the hot water boiler
and auxiliary items at Bldg. 21200, Command Destruct Facility. This is
a combined synopsis/solicitation for commercial items prepared in
accordance with the format in subpart 12.6, as supplemented with
additional information included in this notice. This announcement
constitutes the only solicitation. Quotes are being requested and a
written solicitation will not be issued. There is one (1) solicitation
number associated with this requirement. This is a 100% set-aside for
small business participation only. The solicitation number is
F04684-00-T-0517. The NAICS is 235110 and the SIC is 1711. The Size
Std. is $7,000,000.00. There is one Line Item as follows: Services,
Non-Personal: Contractor to furnish all labor, tools, parts, materials,
facilities, transportation, and supervision necessary to Replace the
Hot Water Boiler and Auxiliary Items at Bldg. 21200, Command Destruct
Facility. Remove existingAjax Hot Water Boiler, gas piping, vent stack,
and remove from the site. Install "Reimers" Model HLR-60 Electric Hot
Water Boiler with staged heating. Furnish and install KA- 36200 3-pole
circuit breaker in the existing distribution center spare location.
Install three (3) each #2-0 THHN and one (1) each #10 THHN copper
conductor from existing breaker panel through existing wireway, through
1.5" EMT to new boiler. Connect inlet and outlet circulating water
piping to existing copper piping. Furnish and install water meter on
the existing make-up water piping Perform operational check of boiler
and system to ensure full operational capability and to ensure proper
temperature and humidity requirements are met. Clean the work site and
remove all old material, equipment, and waste. All work to be
completed NO LATER THAN 31 MAY, 2000. The provisions at FAR 52.212-2
"Evaluation-Commercial Items," applies to this acquisition. Insert in
Para (a), "The following factors will be used to evaluate offers, (1)
price and (2) past performance. Offerors must submit with their quotes
a completed copy of the provision at FAR 52.212-3, Offeror
Representations Certifications-Commercial Items." The clause at FAR
52.214-4, "Contract Terms and Conditions-Commercial Items," applies to
this acquisition along with the following addenda: FAR 52.219-8,
"Notice of Total Small Business Set-Aside." The clause at FAR 52.212-5,
"Contract Terms and Conditions required to implement Statutes or
Executive Orders-Commercial Items," applies to this acquisition along
with the following additional clauses, FAR 52.222-3; Convict Labor
(E.O. 11755), FAR 52.233-2; Protest After Award (31 U.S.C. 3553), FAR
52.222-21; Prohibition of Segregated Facilities (Feb 1999), FAR
52.226-26, Equal Opportunity (E.O. 11246), FAR 52.222-35; Affirmative
Action for Disabled Veterans and Veterans of the Vietnam Era, FAR
52.222-36; Affirmative Action for Workers with Disabilities (29 U.S.C.
793), FAR 52.222-37; Employment Reports on Disabled Veterans and
Veterans of the Vietnam Era (38 U.S.C. 4212), FAR 52.232-33; Payment by
Electronic Funds Transfer-Central Contractor Registration (31 U.S.C.
3332), FAR 52.222-41; Service Contract Act of 1965, as amended (41
U.S.C. 351, et seq.), Department of Labor Wage Determination 94-2063
Revision No. 11 is incorporated. FAR Clauses may be reviewed at
http://farsite.hill.af.mil.. A site visit will be conducted on Tuesday,
4 April 2000 at 9:00 A.M. Quotations must be submitted by written
response NLT (No Later Than) 10 April 2000 to Robert M. Taylor, 30
CONS/LGCC, 806 13th Street, Suite 2, Bldg. 7015, Vandenberg AFB, CA
93437-5226. Oral responses are not acceptable; however, interested
parties may contact me by telephone at (805) 605-3933, FAX at (805)
606-5867, Attn: Robert M. Taylor, or Email at
robert.m.taylor@vandenberg.af.mil. All letters containing quotes must
be sent to Robert M. Taylor and state on the exterior of the package
"RFQ-00-T-0517. Each offeror shall sign his/her quote. An original
signature is required on the quotation. Quote validation is for 60 days
from the date of their quote. Sources responding must provide their
company name, contact point with phone number, and their signature.
Responding sources must be registered in the United States Government
Central Contractor Registration at http//:www.ccr2000.com or
http//:ccr.dlsc.dla.mil. Posted 03/21/00 (D-SN436696). (0081) Loren Data Corp. http://www.ld.com (SYN# 0200 20000323\44-0001.SOL)
44 - Furnace, Steam Plant, Drying Equipment and Nuclear Reactors Index Page
|
|