COMMERCE BUSINESS DAILY ISSUE OF MARCH 23,2000 PSA#2563U.S. Army TACOM-ARDEC, AMSTA-AR-PC, Picatinny Arsenal, NJ 07806-5000 59 -- M439 FUZE SYSTEM LEVEL TESTING AND PRIMARY STANDARD TEST SET SOL
DAAE30-00-R-0207 DUE 051200 POC Mary Lou Desseaux, Contract Specialist,
973-724-3217 WEB: http://procnet.pica.army.mil,
http://procnet.pica.army.mil. E-MAIL: mdess@pica.army.mil,
mdess@pica.army.mil. The U.S. Army Tank-Automotive and Armaments
Command, Armament Research, Development and Engineering Center
(TACOM-ARDEC) intends to issue a sole source contract to Intertek
Laboratories, Warren, NJ 07059 to fabricate a Primary Standard Test Set
for calibration of various test sets related to the 2.75 Inch Rocket
remote set rocket fuzing. This Primary Standard Test Set (PSTS) will
interface with the existing Ballistic Firing Test Sets (BFTS) and
laboratory fuze test sets to make sure they all work within the
calibration limits. The calibration scheme and the design of the PSTS
will be determiined by the contractor. The contractor will also be
responsible for designing the interfaces to the test sets and testing
them to verify the calibration procedure. This effort also involves the
M439 fuze electronic module and complete fuze tests to qualify an
Integrated Circuit (IC) component for the M439 fuze. These timing and
First Article Tests (FAT) of the M439 fuze will be done according to
the M439 fuze specification MIL-F-48877. The contractor will be
responsible for the IC; electronic modules and the M439 fuzes that will
be required to pass the government conducted ballistic testing. A final
report and a drawing package of the PSTS and the modified M439 fuze
will also be required. There is also an option for fabrication of
Appache helicopter based Ballistic Firing Test Set (ABFTS). This test
set will use the Apache helicopter based Rocket Management System
called the Pylon Interface Unit (PIU) for ground firing of 2.75 inch
rockets. This test set will be compatible with the current cabling
system in the field. The building of ABFTS will require the ability to
build the PIU electronic boxes into a field configured system. Note 22
and 26 apply. Posted 03/21/00 (W-SN436409). (0081) Loren Data Corp. http://www.ld.com (SYN# 0229 20000323\59-0004.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|