Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MARCH 24,2000 PSA#2564

Department of the Air Force, Air Combat Command, 7 CONS, 381 Third Street, Dyess AFB, TX, 79607-1581

41 -- AIRCONDITION CHILLER SOL F41652-00-T-0154 DUE 040500 POC David Bustamante, Contract Specialist, Phone (915)696-5569, Fax (915)696-3676, Email david.bustamante@dyess.af.mil -- Tanya Gutka, Contract Specialist, Phone (915) 696-2358, Fax (915) 696-3676, Email WEB: Visit this URL for the latest information about this, http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=F41652-00-T-0 154&LocID=1003. E-MAIL: David Bustamante, david.bustamante@dyess.af.mil. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and written solicitation and will not be issued. F4165200T0154 is issued as a Request for Quotation. The SIC Code for this solicitation is 3585 for Air-conditions/Chillers. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-04. This procurement is being solicited as full and open competition. Line Item 0001, 1 EA AIRCONDITION VOLTAGE 460/3PH/60 SIZE 40 TON STYLE CHILLER TYPE TRANE HERMETIC SCROLL LIQUID CHILLER, AIR-COOLED (COMES WITH FOUR 10-TON COMPRESSORS). R-22 REFRIGERANT. PASSWORD PROTECTED ADAPTIVE CONTROL MICROPROCESSOR LOGIC PANEL W/ CLEAR LANDUAGE DISPLAY PROVIDES ALL CONTROL FUNCTIONS INCLUDING START UP AND SHUTDOWN, LEAVING CHILLED WATER TEMPERATURE CONTROL, COMPRESSOR AND ELECTRONIC EXPANSION VALVE MODULATION, FAN SEQUENCING, ANTI RECYCLE LOGIC, AUTOMATIC LEAD/LAG COMPRESSOR STARTING AND LOAD LIMITING. THE MICROPROCESSOR AUTOMATICALLY TAKES ACTION TO AVOID UNIT SHUTDOWN FROM ABNORMAL OPERATING CONDITIONS ASSOCIATED WITH LOW REFRIGERANT TEMPATURE AND MOTOR CURRENT OVERLOAD. MICROPROCESSOR ALSO CAPABILITIES FOR: REMOTE DISPLAY MODULE, BIDIRECTIONAL COMMUNICATION LINK, CURRENT LIMIT SETPOINT, CURRENT OVERLOAD LOCKOUT, RETURN WATER RESET, ZONE TEMPERATURE RESET, OUTDOOR TEMPERATURE RESET, BALANCED COMPRESSOR STARTS AND HOURS, LOW ABIENT LOCK OUT, PHASE IMBALANCE AND REVERSAL PROTECTION, LOW REFRIGERANT TEMPERATURE AND PRESSURE LOCKOUT, AND CONDENSOR FAN STAGING DETERMINED BY OUTSIDE AIR TEMPERATURE, SATURATED ONDENSING REFRIGERANT TERMPERATURE AND SATURATED EVAPORATOR REFRIGERANT TEMPERATURE. NON-FUSED UNIT-MOUNTED DISCONNECT, FLOW SWITCH P/S. MANUFACTURED BY TRANE, PART# CGAF-C40. Line Item 0002, 2EA AIRCONDTION VOLTAGE 460/60/3PH SIZE 100 TONS STYLE CHILLERTYPE TRANE SERIES _R_ ROTARY LIQUID CHILLER-AIRCOOLED-PACKAGED UNIT. _SALIENT FEATURES ARE AS FOLLOWS_ TWIN HELICAL ROTARY COMPRESSORS (SCREW) R-22 REFRIGERANT, _SEE FURTHER DESCRIPTION_ ADAPTIVE CONTROL MICROPROCESSOR LOGIC PANEL W/CLEAR LANGUAGE DISPLAY W/CAPABILITIES FOR: REMOTE DISPLAY MODULE, CURRENT LIMIT SETPOINT, CURRENT OVERLOAD LOCKOUT, CHILLED WATER TEMPERATURE RESET, LOW ABIENT START CAPABILITY, LOW ABIENT LOCKOUT, PHASE IMBALANCE AND REVERSAL PROTECTION, LOW REFRIGERANT TEMPERATURE AND PRESSURE LOCKOUT, AND OIL FAILURE PROTECTION. 2 REFRIGERANT CIRCUITS, MAXIMUM PHSICAL SIZE OF UNIT MUST NOT EXCEED 16_6_ LENGTH, 7_6_ HEIGHT, AND 7_6_ WIDTH AND 2700 LBS IN WEIGHT. MANUFACTURED BY TRANE PART# RTAA100. Desired delivery to Dyess AFB, TX is 30 days after award. The provision at FAR 52.212-1, Instructions to Offerors Commercial, applies to this acquisition. Only written offers will be accepted. Bidders must specify business size, cage code, duns number, and tax-ID number in their quote. Prospective contractors must be registered in Central Contractor Registration (CCR) to bid on this solicitation. The provision at FAR 52.212-2, Evaluation Commercial, applies to this acquisition and the evaluation criteria in paragraph (a) of the provision shall consist of, in descending order of importance: (i) salient characteristics; (ii) technical capability of the products and services offered to meet the governments requirements; (iii) price: and (iv) transportation costs. FOB point is Destination. Offerors must include a completed copy of the provision at FAR 52.212-3, Offeror Representation and Certifications, -- Commercial Items, with its offer. The provision at DFARS 252.225-7003, Information for Duty-Free Entry Evaluation Applies to this acquisition. The provision/clause at DFARS 252.204-7004, Required Central Contractor Registration, applies to this acquisition. The clause at FAR 52.212-4, Contract Terms and Conditions Commercial Items applies to this acquisition. The clause at FAR 52.212-5, Contract Termsand Conditions Conditions Required to implement Statues or Executive Orders Commercial Items, applies to this acquisition as well as the clauses at FAR 52.222-26, Equal Opportunity (E.O. 11246), 52.222-45, Affirmative Action for Special Disabled and Vietnam Era Veterans (38 U.S.C. 4212). The clause at DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statues or Executive Orders Applicable to Defense Acquisitions of Commercial Items applies to this acquisition as well as the clauses at DFARS 252.225-7001, Buy American Act and Balance of Payment Program (41 U.S.C. 10, E.O. 150582), and 252.225-7036, North American Free Trade Agreement Implementation Act with its Alternate I. The clause at DFARS 252.232-7009, Payment by Electronic Funds Transfer (CCR) applies to this acquisition. Bids are due no later than close of business Thursday, April 5, 2000. SSgt Bustamante will accept quotations by facsimile at 915-696-3676 or via E-Mail at david.bustamante@dyess.af.mil. If there are any questions concerning this procurement, contact SSgt Bustamante at 915-696-2160. Any of the above FAR provisions/clauses will be provided in full text at the request of the contractor. Posted 03/22/00 (D-SN437259). (0082)

Loren Data Corp. http://www.ld.com (SYN# 0205 20000324\41-0001.SOL)


41 - Refrigeration, Air Condition and Air Circulating Equipment Index Page