COMMERCE BUSINESS DAILY ISSUE OF MARCH 31,2000 PSA#2569Commanding Officer, USCG Civil Engineering Unit Miami, 15608 SW 117th
Ave., Miami, FL 33177-1630 95 -- FABRICATION AND DELIVERY OF STEEL PIPE PILES TO VARIOUS USCG
UNITS SOL DTCG82-00-Q-3WC098 DUE 042000 POC Michelle Nammur, Program
Asst. (305) 278-6725 E-MAIL: Michelle Nammur, Program Assistant,
mnammur@ceumiami.uscg.mil. SYNOPSIS/SOLICITATION: This is a combined
synopsis/solicitation for commercial items prepared in accordance with
the format in Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; proposals are being requested and a written
solicitation will not be issued. This solicitation, DTCG82-00-Q-3WC098,
is being issued as a request for quotation (RFQ). The solicitation
document and incorporated provisions and clauses are those in effect
through Federal Acquisition Circular FAC 97-15. This combined
solicitation is being issued as a Small Business Set-Aside. The
standard identification code (SIC) is 3441, size standard of 500.
SCOPE: The contractor is responsible for providing all materials and
services necessary to procure, deliver, and off-load coated steel Pipe
Piles to Coast Guard Group Corpus Christi, TX, Coast Guard Group
Galveston, TX and Coast Guard Group Miami, FL. REFERENCES: (1) ASTM A
252 (1993) Welded and Seamless Steel Pipe Piles, (2) SSPC PS 11.01
(1991) Black (or Dark Red) Coal Tar Epoxy-Polyamide Painting System,
(3) SSPC PS 12.01 (1991) One-Coat Zinc-Rich Painting System, (4) SSPC
SP 10 (1991) Near-White Blast Cleaning, (5) SSPC Paint 16 (1991) Coal
Tar Epoxy-Polyamide Black (or Dark Red) Paint, (6) SSPC Paint 20 (1991)
Zinc-Rich Primers (Type I, "Inorganic", and Type II, "Organic").
SUBMITTALS: (1) Certificate of conformance to standards for the steel
piles, (2) Manufacturer's literature for the Organic Zinc Primer and
the Black Coal Tar Epoxy-Polyamide paints to be approved by a Coast
Guard technical representative. STEEL PILE REQUIREMENTS: All piles
shall conform to ASTM A252. All piles shall be Grade 2 with plain ends
and shall be straight seam welded. One splice per pile may be used if
it is located within 10 feet of either end of the pile and tension
test specimens from sample splices conform to the strength requirements
of Table 1 of ASTM A252. Welds shall be ground down such that they are
smooth and flush withthe pile exterior. A certificate indicating that
the piling was manufactured and tested in accordance with this
specification shall be mailed to the Contracting Officer at the time of
delivery. Steel piles shall be furnished in the lengths and diameters
(outside) as listed in the contract. Pile length tolerance shall be
(+/-) 3 inches. The wall thickness of all steel piles shall be 0.375
inches. The piles shall be coated as specified below. COATING
REQUIREMENTS: Blast clean each pile in accordance with SSPC SP 10.
Apply one Organic Zinc Primer, meeting SSPC Paint 20 Type II, coat to
all surfaces not more than 2 hours after blast cleaning. Organic Zinc
Primer shall be applied in accordance with SSPC PS 12.01 to 2 mils DFT.
Apply Black Coal Tar Epoxy-Polyamide meeting SSPC Paint 16 to all
surfaces after the primer coat is fully dry. The Coal Tar
Epoxy-Polyamide shall be applied in accordance with SSPC PS 11.01 to a
minimum of 16 mils DFT. Both the prime coat (Zinc Primer) and the top
coat (Coal Tar Epoxy) shall be from the same manufacturer to ensure
system compatibility. MARKING REQUIREMENTS: Each pipe pile shall be
legibly marked by stenciling (white paint) or stamping the following
information: Contract Number (ie: DTCG82-00-C-3WC092), year of
manufacture, name of manufacturer, heat number, manufacturing process
(ie: seamless, flash welded, fusion welded, or electric resistance
welded), outside diameter and nominal wall thickness, weight, length,
grade, and the specification number. The letters shall not be less than
3/4 inch high, if stenciled, and not less than 1/4 inch high if
stamped. The required data shall be marked on both ends of each pile.
QUANTITIES/DELIVERY LOCATIONS: Deliver ten (10) 18 inch outside
diameter 60 foot long piles to Commander, U.S. Coast Guard Group,
Harbor Facility, 1201 Navigation Blvd., Corpus Christi, TX 78419-5220,
POC: Aids to Navigation Officer, Ph: (512) 888-3173. Deliver five (5)
18 inch outside diameter 45 foot long piles to Commander, U.S. Coast
Guard Group, One Ferry Rd., Galveston, TX 77553-1912, POC: Aids to
Navigation Officer, Ph: (409) 766-5654. Deliver six (6) 18 inch outside
diameter 60 foot long pile, and three (3) 12.75 inch outside diameter
60 foot long piles to Commander, U.S. Coast Guard Group, 100 MacArthur
Causeway, Miami, FL 33139-5101, POC: Aids to Navigation Officer, Ph:
(305) 535-4311. DELIVERY SCHEDULE: Delivery of piles shall be within 45
days after the contract is awarded to the locations specified above.
The contractor shall notify the consignee at least 3 working days
before delivery of piles. Delivery shall be made during weekdays
between the hours of 8:00 a.m. and 3:00 p.m. LOAD LIMITATION FOR
DELIVERY: Coast Guard Group Miami is located on an island whose only
access is a one-lane bridge. The bridge has for single lane traffic an
HS20-44 load capacity as designated by the American Association of
State and Transportation Officials (AASHTO) which the contractor shall
not violate. QUALITY ASSURANCE: Each pile shall be examined for the
following defects upon delivery: (1) Pile not manufactured as specified
and in accordance with ASTM A252, (2) Diameter varies more than (+/-)
1% from the specified diameter (including outside diameter at welds),
(3) The weight of any pile shall not be more than 15% heavier nor 5%
lighter than that prescribed in Table 2 of ASTM A252, (4) Nominal wall
thickness at any point shall not be less than 12.5% under that
specified, (5) Pipe pile not reasonable straight, (6) Surface
imperfections exist with a depth exceeding 25% of the nominal wall
thickness, and (7) Coating system shall not be severely damaged upon
delivery and unloading. The presence of one or more of these defects
shall be cause for rejection of the pile. Damaged coating systems may
be touched-up' by the contractor in accordance with the manufacturer's
recommendations to meet these requirements. Repair of defects by
welding is permitted only when the depth is not more than 33% of the
nominal wall thickness. BID REQUIREMENTS: Provide the bid in the
following format: Coated Steel Pipe Piles Delivered to Coast Guard
Group Corpus Christi, TX Length O.D. Qty Unit Price Unit Total 60' 18"
10 $_________ each $_______ Subtotal: $_______ Coated Steel Pipe Piles
Delivered to Coast Guard Group Galveston, TX Length O.D. Qty Unit Price
Unit Total 45' 18" 5 $_________ each $_______ Subtotal: $_______ Coated
Steel Pipe Piles Delivered to Coast Guard Group Miami, FL Length O.D.
Qty Unit Price Unit Total 60' 18" 6 $_________ each $_______ 60' 12.75"
3 $_________ each $_______ Subtotal: $_______ Total Lump Sum Bid:
$_________ FAR provision 52.212-1, Instructions to Offerors-Commercial
Items (Nov 1999) applies and is incorporated by reference. Award will
be made to the lowest responsible bidder. Bidders shall complete and
submit with offer provision FAR 52.212-3, Offeror Representations and
Certifications-Commercial Items (Feb 2000) Alternate I (Oct 1998)
Alternate III (Jan 1999). The following clauses are incorporated by
reference: FAR 52.212-4 Contract Terms and Conditions-Commercial Items
(May 1999); FAR 52.212-5 Contract Terms and Conditions Required to
Implement Statutes or Executive Orders-Commercial Items (Feb 2000); FAR
52.219-6 Notice of Total Small Business Set-Aside (Jul 1996); FAR
52.222-21 Prohibition of Segregated Facilities (Feb 1999); FAR
52.222-26 Equal Opportunity (Feb 1999); FAR 52.222-35 Affirmative
Action for Disabled Veterans and Veterans of the Vietnam Era (Apr
1998); FAR 52.222-36 Affirmative Action for Workers with Disabilities
(Jun 1998); FAR 52.222-37 Employment Reports on Disabled Veterans and
Veterans of the Vietnam Era (Jan 1999); FAR 52.225-1 Buy American
Act-Balance of Payments Program-Supplies (Feb 2000); FAR 52.232-33
Mandatory Information for Electronic Funds Transfer Payment (Aug 1996);
FAR 52.246-2 Inspection of Supplies-Fixed Price (Aug 1996); FAR
52.247-15 Contractor Responsibility for Loading and Unloading (Apr
1984); FAR 52.249-1 Termination for Convenience of the
Government(Fixed-Price)(Short Form)(Apr 1984); FAR 52.249-8 Default
(Fixed-Price Supply andService)(Apr 1984). ATTENTION: Minority,
Women-owned, and Disadvantaged Business Enterprises (DBEs)! The
Department of Transportation (DOT), Short-Term Lending Program (STLP)
offers working capital financing in the form of lines of credit to
finance accounts receivable for transportation related contracts.
Maximum line of credit is $500,000 with interest at the prime rate. For
further information, call (800)532-1169. Internet address:
http://osdbuweb.dot.gov. SUBMISSION OF QUOTES: All responsible sources
may submit a quotation, which will be considered by this agency.
Closing date and time for receipt of offers is April 20, 2000, 4:00pm,
Eastern Time. Facsimile offers are acceptable and may be forwarded to
(305)278-6696, Attn: Michelle Nammur. Mail shall be addressed to
Contracting Officer, USCG CEU Miami, 15608 S.W. 117th Ave., Miami, FL
33177-1630. All quotes shall be clearly marked with the contractor's
name, address, phone number, contact person, and solicitation number.
Posted 03/29/00 (W-SN438955). (0089) Loren Data Corp. http://www.ld.com (SYN# 0265 20000331\95-0001.SOL)
95 - Metal Bars, Sheets and Shapes Index Page
|
|