Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 4,2000 PSA#2571

Northern Division Naval Facilities Engineering Command, 10 Industrial Highway, Mail Stop #82, Lester, PA 19113-2090

C -- ENGINEERING AND DESIGN SERVICES FOR VARIOUS MULTI-DISCIPLINE PROJECTS PRIMARILY IN THE STATES OF DE, PA, NY, NJ, MA, CT, RI, NH, ME AND VT SOL N62472-00-D-1400/1401/1402/1403/1404- DUE 050800 POC Tina Phillips, Contract Specialist, 610-595-0643 THIS IS A MODIFICATION TO THE PRE-SOLICITATION NOTICE THAT WAS POSTED IN CDBNET on MARCH 31, 2000: NOTE: THIS NOTICE WAS INCORRECTLY POSTED UNDER CLASSIFICATION CODE "C" AND ACTION CODE "P". NOTICE IS THEREFORE WITHDRAWN FROM THIS SECTION AND IS NOW POSTED UNDER CLASSIFICATION CODE R -- ARCHITECT AND EINGINEERING SERVICES -- CONSTRUCTION -- POTENTIAL SOURCES SOUGHT NOTICE. DESC: ENGINEERING AND DESIGN SERVICES FOR VARIOUS MULTI-DISCIPLINE PROJECTS PRIMARILY IN THE STATES OF DE, PA, NY, NJ, MA, CT, RI, NH, ME, AND VT SOLICITATION NO. N62472-00-D-1400, N62472-00-D-1401, N62472-00-D-1402, N62472-00-D-1403, N62472-00-D-1404 Engineering and design services for five indefinite quantity contracts for the preparation of architectural and engineering studies, plans, specifications, and cost estimates for multi-discipline projects at various military installations primarily in the states of DE, PA, NY, NJ, MA, CT, RI, NH, ME, AND VT. Contract N62472-00-D-1400 will be used primarily for work in NY and NJ. Contract N62472-00-D-1401 will be used primarily for work in PA and DE. Contract N62472-00-D-1402 will be used primarily for work in ME, NH, and VT. Contract N62472-00-D-1403 will be used primarily for work in CT and MA. Contract N62472-00-D-1404 will be used primarily for work in RI. However, work from other states may be added to any contract at the discretion of the Government. The Naval Facilities Engineering Command is moving towards Design-Build as the preferred method for acquiring capital improvements. Though Design-Bid-Build methodologies (with the preparation of 100% Plans and Specifications) will continue to be utilized, a significant number will likely require preparation of Requests for Proposal packages for Design-Build solicitations using abbreviated (0% -- 30%) design documentation. Packages would include elements of site/engineering investigation, architectural programming, and functional/performance specifications. The following services may also be required: facility planning which includes project programming documents (1391 development), development of requirements, preparation of engineering evaluations, project scope, and unit guidance or parametric cost estimating, development of alternatives and economic analysis; analysis of proposed sites for foundations, utilities, access, constraints and identification of environmental issues; facility design/construction packages, design-build RFP packages, government collateral equipment lists, project preliminary hazard analysis, obtaining permits and regulatory approvals, comprehensive interior design, review of the contractor's submittals, field consultation and inspection during construction, Title II Inspection, Operation and Maintenance Support Information (OMSI), and as-built drawing preparation. The initial project will be determined at a later date. Projects assigned to this contract may include work in the following specialties: Civil, Structural, Mechanical, Electrical, Fire Protection, Architectural, Interior Design and Landscape Architecture. Phases and/or pre-priced contract options may be included and will be exercised at the discretion of the government for 0 35%, 35 100% design, and post construction contract award services. Contract award is contingent on availability of funds. Options are normally exercised within several months of completing prior work; however, delays of up to one year are possible. Some projects will require design in the metric system. As part of this contract, an asbestos and/or lead-based paint assessment may be required to determine the presence of hazardous material during removals/demolition or at utility points of connections. Firms must be able to accept work that involves asbestos, lead paint, PCB's, and other hazardous materials. Work will be prepared utilizing AutoCAD Release 14 or higher or Microstation Version 95 or higher depending on the location of the specific project. Specifications will be prepared using SPECINSTACT SGML program, and cost estimates using the "Success" estimating program in aWork Breakdown Structures (WBS) system format will be utilized. Selected firm will be required to provide documents in pdf format for posting to a Government web site during solicitation. Firms are advised that the selected firm, its subsidiaries or affiliates which design or prepare specifications for a construction contract cannot provide the construction services for the same contract. This includes concept design, which includes preparation of project programming documents (DD1391), facility siting studies, environmental assessments, or request for proposals for Design-Build projects, or other activities that result in identification of project scope and cost. The contract requires that the selected firm have on-line access to email via the Internet for exchange of correspondence/information. SIGNIFICANT EVALUATION FACTORS (in order of importance): 1. SPECIALIZED EXPERIENCE. Recent experience of the design team members individually and collectively as a total team (A/E, client, outside agencies) in the type of work required (as described above) and in: a) Performing facility planning studies which includes 1391 development, developing of requirements, preparing engineering evaluations, project scope, and unit guidance or parametric cost estimating. Project development will include development of alternatives and economic analysis. b) Analysis of proposed sites for foundations, utilities, access, constraints and identification of environmental issues. c) Designing and providing construction documents for various facilities, utilities, and site improvements, d) Designing projects to Navy, Air force or other DOD agencies criteria, e) On-site functional analysis and on-site schematics, space programming and budgetary or parametric cost engineering, f) Specialized experience for at least three DDC (direct digital control) projects greater than 10,000 SF conditioned space constructed within the past five years (provide references), g) Designs using AutoCAD, SPECSINTACT, and NAVFAC cost estimating, and, h) Evidenceof experience of both the firm and key personnel in comprehensive interior design, space planning, systems furniture, knowledge of the federal acquisition process and GSA schedules. i) Evidence of prior experience or of the skills needed in the preparation of design/build RFP packages. 2. PROFESSIONAL QUALIFICATIONS: Technical competence by discipline (education, registration and experience) of individual design team members. At a minimum, professional registration is required of one individual in each of the specified disciplines. The team shall include, in addition to the more traditional disciplines, an engineer registered in the discipline of fire protection engineering or a related engineering discipline and include 5 complete years of full time experience dedicated to fire protection engineering since 1994, a registered communications distribution designer (this is a new professional registration), an engineer or architect with a minimum of 10 years roofing and waterproofing design and construction experience, a registered landscape architect. 3. CAPACITY: a) Capacity of the firm and project teams to accomplish multiple, large, and small projects simultaneously, and b) Ability to sustain the loss of key personnel while accomplishing work within required time limits. 4. PAST PERFORMANCE: Past performance ratings by government agencies and private industry with respect to work quality, performance, compliance with schedules and cost control. 5. LOCATION: a) Location in the general geographical area of the anticipated projects, b) Knowledge of local site conditions and applicable regulatory requirements, and c) Ability of the firm to ensure timely response to requests for on site support. 6. SUSTAINABLE DESIGN: Demonstrated success in prescribing the use of recovered materials and achieving waste reduction and energy efficiency in facility designs. 7. SUBCONTRACTOR UTILIZATION: Use of small business, small disadvantaged business, women owned small business firms, historically black colleges and minority institutions, used as primary consultants or subconsultants. 8. VOLUME: Volume of work previously awarded to the firm by the Department of Defense within the past twelve months. Type of Contract: Indefinite Quantity Contract/Firm Fixed Price Task Order Estimated Start Date: September 2000 There will be no dollar limit per project. Estimated construction cost of projects under these contracts will generally not exceed $3,000,000. However, larger dollar value projects may be added at the discretion of the government. The total fee that may be paid under each contract (including the option years) will not exceed $5,000,000 for the entire contract term. The duration of each contract will be for one year from the date of an initial contract award with an option for four additional one-year periods. The minimum guarantee for the entire contract term (including option years) will be satisfied by award of the initial project. The options may be exercised within the time frame specified in the resultant contract at the sole discretion of the Government subject to workload and/or satisfaction of A/E performance under the subject contract. The SIC Code is 8712 and the small business size standard classification is $4,000,000. THE PROPOSED CONTRACTS ARE BEING SET-ASIDE FOR SMALL BUSINESS FIRMS. LARGE BUSINESSES WILL NOT BE CONSIDERED. All contractors are advised that registration in the DOD Central Contractor Registration (CCR) Database is required prior to award of a contract. Failure to be registered in the DOD CCR Database may render your firm ineligible for award. All firms are encouraged to register as soon as possible. Information regarding this registration may be obtained by accessing Northern Division's web site at http://www.efdnorth.navfac.navy.mil or through the point of contact identified for this procurement. A/E firms, which meet the requirements described in this announcement, are invited to submit completed Standard Forms 254 and 255 to the office shown above. Standard Forms 254 and 255 may be downloaded from the following GSA web site: http://www.gsa.gov/forms Block 10 of the Standard Form 255 will include the following: (1) Summary of how the firm meets the stated evaluation criteria for this contract; (2) Matrix documenting proposed team members specialized experience relevant to the subject contract (IN LEFT HAND COLUMN SHOW: Relevant projects (use number of project assigned in Block 8 of Standard Form 255). ACROSS TOP ROW OF MATRIX SHOW: Role of team member (include consultants) on relevant project i.e., Project Manager, Project Engineer, Architect, etc ); (3) Copies of performance evaluations and/or letters of commendations (as attachments) for office making this submission; (4) List of relevant projects and date design completion scheduled, date design completed, and final cost estimate compared to the contract award amount. Firms must also indicate if they are a subsidiary, and if so, must state if they are normally subject to management decisions, bookkeeping, and policies of their holding or parent company. Also indicate if firm is an incorporating subsidiary that operates under a firm name different from the parent company. The qualification statement should clearly indicate the office location where the work will be performed and the qualifications of the individuals anticipated to work on the contract and their geographical location. SELECTION INTERVIEW REQUIREMENTS: At the selection interview, the A/E firms slated for interviews must submit a listing of present name and telephone numbers of officers at their financial institutions, and performance references. Firms having a current SF 254 on file with this office and those responding to the announcement by 4:00 p.m. EST on 8 May 2000 will be considered. ALL HAND CARRIED SUBMITTALS MUST BE DEPOSITED IN THE BID BOX WHICH IS LOCATED IN THE LOBBY AT THE ABOVE GIVEN ADDRESS PRIOR TO THE TIME AND DATE SPECIFIED. PLACE LABEL ON THE OUTERMOST ENVELOPE IN WHICH YOUR SUBMITTAL IS DELIVERED STATING "SUBMITTAL ENCLOSED", "CONTRACT NUMBER (show appropriate contract number) AND "DATE DUE 8 May 2000." Facsimile responses will not be accepted. Late responses will be handled in accordance with FAR 52.215-10. No material will be returned. Firms responding to this advertisement are requested to submit only ONE COPY of qualification statements. Respondents may supplement this proposal with graphic material and photographs that best demonstrate capabilities of the team proposed by the project. THIS IS NOT A REQUEST FOR A PROPOSAL. CITE: (W-091 SN440112) Posted 03/31/00 (W-SN440216). (0091)

Loren Data Corp. http://www.ld.com (SYN# 0011 20000404\C-0001.SOL)


C - Architect and Engineering Services - Construction Index Page