COMMERCE BUSINESS DAILY ISSUE OF APRIL 5,2000 PSA#2572HQ ESC, Milsatcom terminals Program Office, ESC/MCK, 50 = Griffiss St.,
Hanscom AFB, MA 01731-1620 59 -- AC/DC POWER ADAPTER FOR TACTICAL UHF SATCOM TERMINAL SOL
F1962800R0039 DUE 041000 POC William Donaldson, Contract Specialist,
781-271-6091 WEB: ESC Business Opportunities Web Page,
http://www.herbb.hanscom.af.mil. E-MAIL: Click Here to E-mail the POC,
bill.donaldson@hanscom.af.mil. Power Adapters and other accessories
(AC/DC input cabling and operations and maintenance manual),
Maintenance (optional). The = MILSATCOM Terminals Program Office is
seeking commercial off-the-shelf (COTS)/non-developmental item (NDI)
AC/DC Power Adapters (herein = referred to as the adapter) for use with
Ultra-High Frequency (UHF) satellite communications (SATCOM) terminals
in Air Force fixed-site and transportable ground tactical operations.
The adapter shall be electrically and physically compatible with
Receiver/Transmitter (R/T) types, specifically the AN/PSC-5A and the
Multi-Band, Multi-Mode Radio (MBMMR) manufactured by Raytheon Systems
Corporation-Fort Wayne, IN. = When equipped with an internal
rechargeable battery, the adapter shall = provide uninterruptible power
to the R/T in situations where input AC or DC = power is interrupted.
As an objective, the internal battery type shall be one that is
available within the military supply chain. DC output characteristics
of the adapter include regulated 24 VDC nominal output (objectively
+5,-0 VDC) at sufficient current to operate the specified R/Ts at rated
transmit power, and as an objective at such = output current without
the need for an internal battery. As a minimum, with normal input
power, it shall be possible to support R/T operation at maximum
transmit power on a continuous basis for at least 1 hour = without
completely discharging the internal battery. Input power shall be =
either AC or DC, prioritized on AC if both are present. AC input =
characteristics shall range from 95 to 130 VAC, 47 to 440 Hz or 95 to
240 VAC, 47 to 63 Hz. DC input characteristics shall range from 11 to
33 VDC. The = adapter shall completely recharge the internal battery in
4 hours or less. An auxiliary output of 24 VDC nominal at up to 1
Ampere shall be provided through a separate connector. As = an
objective, this connector will interface directly or through a short
adapter cable with a type MS3116F8-2P cable plug (pin A +24 VDC, pin B
Ground) as used with ancillaryequipment. Input and output circuits =
shall include EMI filtering, with objective EMI performance levels
compatible with appropriate line conducted, line emission and radiated
= requirements of MIL-STD-461E. Protection for over-temperature, and
output = over-voltage and short-circuit conditions are desired
features. The AC input line shall be protected by circuit breakers or
fuse. DC input voltage surge suppression capability shall be at least
100 V, and objectively = compatible with MIL-STD-1275. Physical
dimensions shall be compatible with the specified R/T(s) battery side
interface (nominally 9.2 x 2.9 inches) by 8.0 inches maximum depth.
Weight (less internal battery) shall be less than 4 pounds. =
Environmental capabilities shall include an operating temperature range
of -30=B0 C = to +55=B0 C, with -30=B0 C to +70=B0 C as an objective,
and a = non-operating range of -40=B0 C to +70=B0 C. The adapter shall
physically interface to the specified R/Ts with two over-center
latches. When mated with an R/T =with sealing gasket, the adapter shall
not leak under 3 feet immersion in seawater. Other environmental
characteristics shall include operation = in up to 95% relative
humidity, including condensation, operating altitude = of 15,000 feet
and non-operating altitude of 40,000 feet, and sand and = dust
environments. Cooling shall be by free convection only. Items to be
supplied with the adapter include internal battery, AC/DC input cabling
(AC input termination in grounded North American style line plug, and
= DC input termination as insulated plug or clip), and an operation and
maintenance manual. When calling, be prepared to state name, address,
and solicitation number. Respondents to this synopsis/solicitation
should identify whether they = are a large or small business and
provide their company's name, address, telephone number, and a Point of
Contact (POC). Any proprietary information submitted should be
identified as such. The Government = will not reimburse respondents for
any cost associated with submission of = the information being
requested or reimburse expenses incurred to = interested parties for
responses to this synopsis. Posted 04/03/00 (D-SN440603). (0094) Loren Data Corp. http://www.ld.com (SYN# 0230 20000405\59-0009.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|