COMMERCE BUSINESS DAILY ISSUE OF APRIL 5,2000 PSA#2572National Institute of Standards & Technology, Acquisition &
Assistance Div.,100 Bureau Drive Stop 3572, Bldg. 301, Rm B117,
Gaithersburg, MD 20899-3572 66 -- COMPLETE LOW TEMPERATURE MICRO-PROBE SYSTEM SOL 53SBNB060054 DUE
042100 POC Kathy Fain, Contract Specialist (301) 975-6337, or Alba
Sanchez, Contracting Officer (301) 975-6344; FAX (301)963-7732 WEB:
NIST Contracts Homepage,
http://www.nist.gov/admin/od/contract/contract.htm. E-MAIL: NIST
Contracts Office, Contract@nist.gov. THIS IS A COMBINED
SYNOPSIS/SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH
THE FORMAT IN FAR SUBPART 12.6, AS SUPPLEMENTED WITH ADDITIONAL
INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE
ONLY SOLICITATION; QUOTES ARE BEING REQUESTED AND A WRITTEN
SOLICITATION WILL NOT BE ISSUED. SOLICITATION NUMBER 53SBNB060054 IS
BEING ISSUED AS A REQUEST FOR QUOTATION (RFQ) USING SIMPLIFIED
ACQUISITION PROCEDURES. Incorporated provisions and clauses are those
in effect through Federal Acquisition Circular 97-15. This acquisition
is not aside for small businesses. The SIC code is 3559 and the
related small business standard size is 500 employees. The National
Institute of Standards and Technology's Semiconductor Electronics
Division has a requirement for a complete low temperature micro-probe
system. The Contract Line Item Number (CLIN), quantity, and unit issue
are as follows: CLIN 0001: programmable temperature controller with
control software, one (1) each; CLIN 0002: refrigerator, one (1) each;
CLIN 0003: manipulators with probe tips, four (4) each; CLIN 0004: a
seven port vacuum chamber with one fused-silica window, one (1) each;
CLIN 0005: accessories necessary for nitrogen gas operation from 80
Kelvin to 400 Kelvin, one (1) set; CLIN 0006: accessories necessary for
liquid helium or liquid nitrogen operation from 10 Kelvin to 400
Kelvin, one (1) set; CLIN 0007 the ability to hold samples of at least
1 centimeter by 1 centimeter and appropriate sample mounting kit, one
(1) each; and CLIN 0008: pumps, regulators, and vacuum accessories
necessary for operation, one (1) set. The system should also have the
following capabilities or traits: 1. temperature stability of 50
milliKelvin or better, 2. temperature resolution of 0.01 Kelvin or
better, 3. temperature sensing near the sample mounting surface, 4.
probes with travel of at least 1 inch by 1 inch by 0.25 inch and
positioning accuracy of 50 micrometers or better, 5. temperature
controller should interface to a computer using RS-232C and IEEE-488
communications, 6. system shall take no more than 20 minutes to cool
from 300K to 80K, 7. system shall take no more than 5 minutes to warm
from 80K to 300K, 8. system must be capable of being made light tight,
9. windows must be frost free at all times, 10. system must be
compatible with zoom microscopes, 11. system must be compatible.
Responses are due no later than 3:00 p.m., April 21, 2000, Washington
DC time, to Kathy Fain, National Institute of Standards and Technology,
Aquisition and Assistance Division, Building 301, Room B117, 100 Bureau
Drive STOP 3572, Gaithersburg, MD 20899-3572. Faxed quotations will NOT
be accepted. Posted 04/03/00 (W-SN440651). (0094) Loren Data Corp. http://www.ld.com (SYN# 0252 20000405\66-0003.SOL)