Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 6,2000 PSA#2573

Hqs, USARAK, Directorate of Contracting, P.O. Box 5-525, Bldg 977, Fort Richardson, Alaska 99505-0525

Z -- REPLACE GENERATOR, BLDG. 654 (FIRE STATION), FORT RICHARDSON, ALASKA SOL DAPC49-00-B-0003 DUE 051900 POC Patricia Hanson or Shirley Lucas, (907) 384-7105 or facsimile (907) 384-7112 WEB: When available on the web page, download through "File", http://www.usarak.army.mil/doc/contracts.htm. E-MAIL: Click here to contact the Contract Specialist or the, patricia.hanson@richardson.army.mil or shirley.lucas@richardson.army.mil. The contractor shall provide all labor, supervision, equipment, materials, supplies, and do all things necessary to furnish and install an emergency generator system as indicated by the specifications and drawings furnished with this solicitation. The project includes, but is not limited to, the following work: Demo existing emergency generator, fuel system and associated appurtenances. Patch duct and pipe wall penetrations. Demo concrete panels covering basement access above generator. Relocate piping that penetrates concrete panels. Install new, removable, weather-proof concrete panels on basement access, as specified. Provide and install new basement exhaust system, including new duct, duct fittings, fan, dampers, wiring, controls,etc. for a complete exhaust system. Exhaust fan shall be energized when temperature in the basement goes above 70 degrees F, or when the shower light is on. Provide and install concrete pad and foundation for generator and enclosure, and building walkway according to plansand specs. Provide and install thermal insulation and vapor barriers at walls, roof, ceiling and foundation. Provide and install 50KW generator system with 120 gallon subbase day tank fuel system with transfer pump, controls,and associated equipment. Provide and install 500 gallon fuel storage tank and associated piping and controls to integrate with new generator and fuel system. Relocate existing compressor station located in the fire extinguisher maintenance bay to the new location inside the generator enclosure. Reroute the compressor piping system to provide service equal to existing. Insulate compressor piping passing between enclosure and fire extinguisher bay wall and provide pipe support as specified. Provide and install single enclosure for the generator system, the fuel storage tank and the compressor station. The generator, fuel storage tank, and compressor station shall each be located in separate rooms within the single enclosure. The generator room shall have walls and ceiling with a minimum 1hour fire rating. Each room shall be accessible from the outside through doors provided in accordance with the plans and specs. The compressor room shall be heated with 3KW wall-mounted units w/adjustable thermostats and integral blowers to maintain a minimum temperature of 50 degrees F. Replace existing Master Distribution Panel, as specified. Posted 04/04/00 (W-SN441284). (0095)

Loren Data Corp. http://www.ld.com (SYN# 0114 20000406\Z-0018.SOL)


Z - Maintenance, Repair or Alteration of Real Property Index Page