COMMERCE BUSINESS DAILY ISSUE OF APRIL 12,2000 PSA#2577Regional Officer in Charge of Contracts, Naval Facilities Engineering
Command, Code R120, 4262 Radford Drive, Honolulu, HI 96818-3296 99 -- INSTALL HURRICANE TIES AT QTRS 25,28,29,37,39 MAKALAPA AND SOL
N62742-00-Q-2801 DUE 042400 POC Joyce E. Higa, Manager, (808) 474-9353,
or Noreen J. Madela (808) 474-3047 E-MAIL: Click here to contact the
contracting officer via, madelanj@pwcpearl.navy.mil. 1. General
Requirements. Provide labor, materials, equipment, transportation, and
supervision necessary for the installation of hurricane ties to
intersection of rafters and top plate of dwelling and to the front
entry support posts (header and concrete slab). Contractor shall be
responsible for proper installation and fit of the fasteners that will
penetrate through the freeze boards, drop siding, and into the top
plates of the stud walls, and use of the proper fasteners and anchors
for the front entry support posts. Use metal paint primer, plastic
coating (Plasti-Dip or equal for connectors and fasteners), and two
coats of finish and touch up paint to disturbed areas to match
existing. Work shall be performed in accordance with normal industry
standards and practices and as noted herein. 2. Product. a. Hurricane
ties shall be 14 gauge heavy duty galvanized steel or better. b.
Manufacturer's standard accessories such as fasteners, bolts, concrete
anchors, and metal paint primer, plastic coating (forconnectors and
fasteners), and finish paint. Posted 04/09/00 (W-SN442999). (0100) Loren Data Corp. http://www.ld.com (SYN# 0441 20000412\99-0018.SOL)