|
COMMERCE BUSINESS DAILY ISSUE OF APRIL 19,2000 PSA#2582COMNAV-SPECWAR-GRU One, USNAB Coronado, 3632 Guadalcanal Road, Bldg
156, San Diego, CA 92155 84 -- FIRE RETARDANT IMERSION SUIT SOL USZA94-00-Q-0992 DUE 050300 POC
CONSTANCE L. McCARROLL (619)437-2417 WEB: PROCUREMENT,
WWW.USA.GOV/PROCUREMENT/INDEX.HTML. E-MAIL: CLMCCARROLL@NSWG1.NAVY.MIL,
CLMCCARROLL@NSWG1.NAVY.MIL. THIS IS A COMBINED SYNOPSIS/SOLICIATION FOR
COMMERICAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN FAR SUBPART
12.6, AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDE THIS NOTICE.
THIS PROCUREMENT IS SET ASIDE FOR SMALL BUSINESS. ALL RESPONSIBLE
SOURCES MAY SUBMIT AN OFFER. THIS ANNOUNCEMENT CONSTITUTED THE ONLY
SOLICIATION, PROPOSAL ARE BEING REQUESTED A SEPARATED WRITTEN
SOLICIATION NUMBER USZA94-00-Q-0992 APPLIES AND ISSUED AS A REQUEST FOR
PROPOSAL. THIS SOLICIATION WILL DOCUMENT AND INCORPORATED PROVISIONS
AND CLAUSES ARE THOSE ACQUISITION CIRCULAR 97-16 AND DEFENSE
ACQUISITION CIRCULAR (CORRECTION).THE GOVERNMENT INTENDS TO PURCHASE 49
FIRE RETARDANT IMERSION SUITS OR EQUAL. SIZES TO INCLUDES MEDIUM 18 EA,
MEDIUM TALL 4 EA, LARGE 17 EA, LARGE TALL 8 EA, EXTRA TALL 2 EA. SUITS
SHOULD BE FULL LATEX NECK SEAL, WRIST SEALS, ONE PIECE DOLMAN TYPE
SLEEVES, FORMING THE FRONT BODY AND BACK BODY TO THE WAIST, HOOK, AND
PILE TAB AT EACH WRIST. CHEST TOLERANCE IS 5CM LARGER THAN NORMAL. ONE
PIECE DOLMAN LEG, FORMING EACH SIDE UP TO WAIST WITH PLAIN ANKLES,
ATTACHED REI GORTEX OVERSTOCK SEWN INTO THE LEGS. ONE PIECE FILE FABRIC
PLACED ON EACH SHOULDER (4"X4"). ONE THREE DIVISION PEN POCKET ON A
SELF FABRIC CARRIER AT THE UPPER LEFT SLEEVE. TWO INCH ELASTIC BACK
WAIST IN AN EXTERNAL SELF FABRIC CHANNEL. WATERPROOF ZIPPER ENTRY
ACROSS SHOULDER BLADES (WHEN ZIPPER IS CLOSED SLIDER IS ON RIGHT
SHOULDER); A HORIZONTAL, WATERPROOF ACCESS ZIPPER FLY. ONE FRONT THIGH
PATCH POCKET WITH HOOK AND PILE FASTENING FLAP ON UPPER RIGHT LEG.ONE
BOXED BELLOWS PATCH POCKET WITH HOOK AND PILE FASTENING FLAP ON EACH
LEG (PLACED ON THE OUTSIDE SEAM). ALL POCKETS HAVE PUNCHED DRAINAGE
HOLES. SELF FABRIC INTERNAL REINFORCED PATCHES ON SEAT, KNEE, AND
ELBOWS. NOMEX III ON THE FACE AND MODACRYLIC FLAME RETARDANT LINER, 180
G/M2 FOR THE FACE AND TOTAL OF 310 G/M2. FLAME RESISTANCE SHALL INCLUDE
NO IGNITION, NO HOLE, AND NO AFTERGLOW. WATERPROOFING SHALL BE TESTED
FOR WINDPROOF SPECS LESS THAN .02CM3/CM2/SECOND. WATER VAPOR
TRANSMISSION SHALL BE GREATER THAN 4500 G/M2/24HRS OR EQUAL. MUST MEET
THE REQUIREMENT FOR AMERICAN STANDARD TEST METHOD (ASTM). CONTRACTOR
MUST SUBMIT SAMPLES AND LITERATURES. AWARD SHALL BE MADE TO THE
TECHNICALLY ACCEPTABLE LOW QUOTE. DFARS 204.7302, PROSPECTIVE
CONTRACTORS MUST BE CENTRAL CONTRACTOR REGISTERED (CCR). COMMERICAL
PROCEDURES AS OUTLINED IN FAR 12 AND IN CONJUNCTION WITH FAR 13 ARE
APPLICABLE. THE ANTICIPATED AWARD DATE IS 04 MAY 2000. ALL RESPONSIBLE
QUOTATIONS MAY BE SENT FACSIMILE OR VIA MAIL. FACSIMILE NUMBER
619-437-3547/ E.G.,"SEE NOTE(s) 22 and 23". Posted 04/17/00
(W-SN445855). (0108) Loren Data Corp. http://www.ld.com (SYN# 0263 20000419\84-0003.SOL)
84 - Clothing, Individual Equipment and Insignia Index Page
|
|