Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 20,2000 PSA#2583

Department of the Air Force, Air Force Materiel Command, AFFTC -- AF Flight Test Center, 30 North Wolfe Avenue, Edwards AFB, CA, 93523

41 -- PURCHASE EVAPORATIVE COOLERS AND INSTALL HVAC DUCTING SOL F0470000Q1275 DUE 050400 POC Kim Davis, Contract Specialist, Phone 661-277-9554, Fax 661-277-0473, Email kim.davis@edwards.af.mil -- Nick Condos, Contract Specialist, Phone DSN527-9118, Fax 661-275-7883, Email WEB: Visit this URL for the latest information about this, http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=F0470000Q 1275&LocID=906. E-MAIL: Kim Davis, kim.davis@edwards.af.mil. The Air Force Flight Test Center has a requirement for the following: Provide two (2) each, Evaporative Coolers, MFR: Trane, Model Number: ACEA420. The model number provided above is meant to show the Government_s minimum requirements. Offerors can quote on equals. The offered units shall meet the following performance requirements: Minimum 46,000CFM, minimum 480 volts, minimum 30 hp blower motor, two speed, one winding motor, TEFC type, horizontal discharge blower, two position blower section, pre-wired starter, spray motor, transformer, prewired non-fused disconnect switch, Maxiaire or equal prefilter, 12_ Celdek or equal, cooling pad, pre-existing pad dimensions are 156_ long X 75_ wide, and unit must discharge out the side. Provide two (2) each, Evaporative Coolers, MFR: Trane, Model Number: ACEA260. The model number provided above is meant to show the Government_s minimum requirements. Offerors can quote on equals. The offered units shall meet the following performance requirements: Minimum 10,000CFM, minimum 480 volts, minimum 3 phase, control transformer, water pumps -- minimum 115 volts, minimum 5hp blower motor, two speed, one winding motor, TEFC type, horizontal discharge blower section, pre-wired starter, spray motor, transformer, pre-wired non-fused disconnect switch, Maxiaire or equal prefilter, 12_ Celdek or equal cooling pad, pre-existing pad dimensions are 77_ long X 56_ and unit must discharge out the side. Install air conditioning ducting with external installation and metal clading per attached reference sheets. The reference sheets depict approximate measurements. Offers quoting on equals must provide descriptive literature to the extent necessary to allow the Government to determine the technical acceptability of the equal item. This acquisition is for a small business set-aside; the standard industrial classification code is 3585. The size standard is 750. No hard copies of the RFQ will be mailed or faxed. Telephone requests to be placed on a mailing list will not be honored. The anticipated issuance date of the RFQ on the Internet is 19 April 00. An escorted site visit is tentatively scheduled for 25 April 00 at 10:00 a.m. Those interested in attending the site visit should fax their name, business name and phone number to Kim Davis at 661-277-0473. Anticipated Quotation due date is 4 May 00 and anticipated award date is 11 May 00. FAX questions to Kim Davis at 661-277-0473. The subject solicitation is located at the following internet address: http://BSX.ORG. Once at the BSX site, click on the following links to get to the Solicitations & Synopses folders: 1. Click on EDWARDS MARKETPLACE link. (located under the BSX Marketplace folder) 2. Click on the BUSINESS OPPORTUNITIES folder link. 3. All Solicitations are located in the LOCAL BID BOARD folder. 4. All Synopses are located in the LOCAL SYNOPSES folder. REQUIREMENTS: 1. Internet browser must be Internet Explorer or Netscape Navigator version 4.0 or higher. 2. Most files are of type PDF and are viewable with the Adobe Acrobat Reader. 3. Files requiring special viewer plugins are noted. For problems viewing and/or downloading Solicitations and Synopses, please call the BSX HelpDesk at (661) 277-0106. Posted 04/18/00 (D-SN446318). (0109)

Loren Data Corp. http://www.ld.com (SYN# 0200 20000420\41-0002.SOL)


41 - Refrigeration, Air Condition and Air Circulating Equipment Index Page