Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 24,2000 PSA#2585

Dahlgren Division, Naval Surface Warfare Center, 17320 Dahlgren Road, Dahlgren, VA 22448-5100

59 -- TRAVELING WAVE TUBE AMPLIFIER SOL N00178-00-Q-3009 DUE 050100 POC sd13 (540) 653-7765 WEB: Dahlgren Division, Naval Surface Warfare Center, http://www.nswc.navy.mil/supply. E-MAIL: Dahlgren Division, Naval Surface Warfare Center, sd13@nswc.navy.mil. Description. The Government requires a traveling wave tube amplifier, quantity of one, meeting or exceeding the following specifications: (A) 2 to 8 GHZ operating frequency range. (B) 200W minimum power output at output connector. (C) AMP gain (including preamplifier gain) of at least 53 dB. (D) If a preamplifier is necessary to achieve gain/output power specified, it shall be solid state and internal to the amplifier unit. (E) Gain flatness of plus or minus 13 dB, maximum, when operating at rated power. (F) Input impedance of 50 Ohms, VSWR 2.0:1, maximum. (G) Output impedance of 50 Ohms, VSWR 2.5:1 typical. (H) Load VSWR 2.0:1, maximum, for continuous operation; any value for operation without damage or oscillation. (I) At its output connector, the amplifier shall be able to faithfully reproduce AM, FM, or pulse modulation appearing on the input signal. (J) Harmonic content of -3 dBc, or lower, typical at lower band edge. (K) Noise and spurious of -50 dBc, or lower, typical, excluding harmonics. (L) Connectors shall be: RF Input of Type N female, RF Output of Type N female, and RF Output Sampling Port of Type N female. (M) Immediately capable of GPIB operation, with an IEEE 488 interface. (N) Have primary power range of 200 to 260 VAC single phase and frequency of 47 to 63 Hz. (O) Have power consumption of 2.6 kVA or less typical and 3.0 kVA maximum. (P) Utilize forced-air cooling. (Q) Weigh no more than 120 lbs (54 kg). (R) Have dimensions which permit fit within standard 19-inch width rack and with height no greater than 12 inches. THIS ANNOUNCEMENT CONSTITUTES THE ONLY REQUEST FOR QUOTATION AS ALL ITEMS ARE SPECIFIED BY THIS CBD NOTICE. SUBMIT FAXED, SIGNED, DATED QUOTATIONS NLT 2:00 PM 01 May 2000 TO 540-653-6810, Attn: Code SD136 at NSWCDD, 17320 Dahlgren Rd, Dahlgren, VA 22448, 540-653-7765. IT IS THE OFFEROR'S RESPONSIBILITY TO ASSURE THE QUOTE IS RECEIVED TIMELY, LEGIBLE, AND COMPLETE.AS A MINIMUM, QUOTATIONS MUST INCLUDE: (1) Reference to Quotation Number N00178-00-Q-3009. (2) Quoter's name/address/point of contact/phone number/email address. (3) Clear identification of the offered product, model number, and prices for each offered product. (4) Descriptive literature (NTE 5 pages) which clearly addresses each of the minimum specifications. QUOTES FAILING TO SUBMIT THE ABOVE INFORMATION MAY BE EXCLUDED FROM CONSIDERATION. THE GOVERNMENT RESERVES THE RIGHT TO REQUIRE A NO-COST DEMONSTRATION AT NSWCDD OF PROPOSED PRODUCTS TO VERIFY COMPLIANCE WITH THE MINIMUM SPECIFICATIONS. Award is to be made under Simplified Acquisition Procedures. Quotations will be evaluated for technical capability of the items to meet the Navy's needs/specifications, past performance and price. All responsible sources may submit a firm fixed-priced, faxed quotation, which shall be considered. Posted 04/20/00 (W-SN446903). (0111)

Loren Data Corp. http://www.ld.com (SYN# 0225 20000424\59-0004.SOL)


59 - Electrical and Electronic Equipment Components Index Page