COMMERCE BUSINESS DAILY ISSUE OF MAY 3,2000 PSA#2592Bechtel National, Inc., P.O. Box 193965 -- 45/08/C33, San Francisco, CA
94119-3695 D -- TELECOMMUNICATIONS SYSTEMS INTEGRATOR FOR THE ABERDEEN CHEMICAL
AGENT DEMILITARIZATION PROJECT SOL 24115-10A-HC1-EF00-00135 DUE 052500
POC Jim L. Willman, 410-436-6269 Bechtel National, Inc. is the Systems
Contractor for the Aberdeen Chemical Agent Disposal Facility Project
located at the Aberdeen Proving Grounds, Edgewood, MD. We are
conducting a two-step procurement for a Single Subcontractor to provide
design, engineering, procurement, installation, testing (with a
scheduled Period of Performance of 02 October, 2000 through 01 March,
2002) and follow-on maintenance (through October, 2004) of an
integrated Telecommunications System consisting of eight (8)
sub-systems, for the ABCDF Aberdeen Proving Ground Project as a
turn-key package. The eight (8) Telecommunications sub-systems consist
of: 1) Closed Circuit Television System (CCTV) consisting of
approximately 114 pan/tilt/zoom and 18 fixed cameras with all controls.
2) Support Radio System plus Radio Fire Reporting System and Paging
System consisting of base stations with encryption in 14 buildings, 51
portable radios, and interfacing with existing Aberdeen Proving
Grounds (Army) radio systems. 3) DPE (Demilitarization Protective
Ensemble) Radio System for Chemical Suited Working Personnel providing
full coverage within all working areas. 4) OSP System (Outside Plant
System), the backbone system, consisting of fiber optic and copper
cable for voice, data, LAN, and video. 5) Plant Security/Access Control
System consisting of approximately 64 card readers in 32 locations and
interfaced with control consoles. 6) PAGA System (Public Address and
General Alarm System) to provide multi-alarm tone notices to a minimum
of 7 zones with interface to main control consoles, telephone systems,
and channel paging. 7) Inner-Communication System consisting of
hardwire system to provide full duplex communication within the
Facility work areas. 8) Inside Plant System (Telephones) consisting of
approximately 120 digital and 290 analog phones with voicemail, 3-way
conferencing, etc. (Note: Will interface with existing 600 line Lucent
Definity Switch). The first step in this procurement is to meet the
technical requirements which consist of: 1) Previous successful
performance of similar Projects of similar scope. 2) Must have
qualified Engineers, Designers, Installers, and Maintenance personnel
either on staff or specifically identified as sub-tier subcontractors
and/or consultants. 3) Ability to provide Maryland PE stamp and other
certifications required for engineering, design, installation, testing,
and certifications. 3) Must have personnel on staff or readily
available as specifically identified sub-tier subcontractors and/or
consultants with experience in the following: Military Trunking
Systems, Radio Paging, Kingfisher Radio Fire Reporting, Emergency Radio
Systems, DPE Radio Systems, Closed Circuit Television in a Chemical
Environment, Video and Audio Recording, Building Modeling Programs for
Camera and Radio Equipment Placement, PAGA in a Chemical Environment,
Lucent PBX, Conduit Installation in a Chemical Area, Copper and
Fiber-Optic Cabling, LAN/WAN, DATA Networking, and Complete Facilities
Maintenance of all systems. If you have proven capability to provide
the above requirements, please submit your written reply, to include as
a minimum: 1) Complete company profile (include business size and/or
socio-economic status, i.e. Large, Small, Small Disadvantaged, Small
Woman-Owned, HUBZone; and a current audited financial report) and
contact information. 2) Written narrative describing how you meet each
of the identified requirements. 3) Resumes of key personnel, whether
employees or sub-tier subcontractors and/or consultants, that show
experience for each identified requirement. 4) A complete experience
listing with reference names and phone numbers. 5) Relate items 2-4
above to the individual plant systems. Your technical submittal will be
evaluated and scored to the following priorities, with a minimum
scoring of 80% required to be determined as Technically Acceptable and
Qualified to receive a formal Request for Commercial Proposal: 1) CCTV
System 25% 2) Support Radio System 15% 3) DPE Radio System 15% 4)
Outside Plant System 15% 5) Plant Security/Access Control System 10% 6)
PAGA System 10% 7) Inner-Communication System 5% 8) Inside Plant System
5% Your technical proposals must be submitted no later than May 25,
2000 to: Bechtel National, Inc. PO Box 72 APG-EA, MD 21010-0072
Attention: Jim L. Willman or by e-mail to: jlwillma@bechtel.com The
technical evaluation is expected to be complete by June 8, 2000,
followed by issue of the Request for Commercial Proposal on June 15,
2000, to those firms meeting the 80% technical scoring. If you have any
questions or require any additional information, please contact Jim L.
Willman, Bechtel Subcontracts Supervisor, ABCDF Project at (phone)
410-436-6369, (FAX) 410-436-9025, or (e-mail) per above. Posted
05/01/00 (W-SN450032). (0122) Loren Data Corp. http://www.ld.com (SYN# 0031 20000503\D-0012.SOL)
D - Automatic Data Processing and Telecommunication Services Index Page
|
|