COMMERCE BUSINESS DAILY ISSUE OF MAY 15,2000 PSA#2600Fleet & Industrial Supply Center, Regional Contracts Dept, Attn: Bid
Officer/Code 210A94, 937 N. Harbor Drive, Suite 212, San Diego, CA
92132-0212 35 -- CONVEYORS AND SORTING PLATFORM SOL N00244-00-T-0888-0001 DUE
052600 POC Contract Specialist Bill Archambeault, (619)532-2894;
(619)532-2575(fax) WEB: Click here to find more information on FISC San
Diego, http://www.sd.fisc.navy.mil. E-MAIL: Click here to contact
Contract Specialist (619)532-2894,,
William_R_Archambeault@sd.fisc.navy.mil. The purpose of this amendment
is to clarify the specifications requirements for two conveyors and a
sorting platform and extend the closing date of the solicitation. The
requested material shall meet or exceed the following salient
characteristics: A) Electrical Controls -- 1) Power source will be 460
VAC, 60 Hz, 3-phase, 2) Interlocking electrical controls mounted
inside NEMA 12 enclosure, with lockable disconnect switches, 3) All
necessary control logic, timers, magnetic starters, and/or AC variable
speed drives, electronic soft-starters, push buttons, pilot lights,
maintained and emergency stop buttons, 4) Emergency cable switches and
start warning horns as required, meeting all safety standards for
conveyors, 5) Complete documentation of the control system shall be
provided, including schematic diagrams, conduit diagrams for
installation, spare parts list, operations manuals, and sequence of
operation. Documentation shall conform to ANSI/NFPS 79; B) Slider-bed
Conveyor -- 1) Nominal dimensions: a) belt width 30", b) belt path
style A, horizontal, c) Horizontal projection of 27'6" between centers
of head and tail pulleys, 2) Belting: a) MOR P.I.W. 150 belting with
1/8" thick moderately oil-resistant top cover, 3) Pulleys: a) crown
faced steel, 4) Return idlers: a) steel, 5) Shafting: a) cold finished
steel, mounted in heavy duty pillow blocks, 6) Drive: a) minimum 1750
RPM electric motor, continuous duty, V-belt drive to gear reducer with
totally enclosed guard, 7) Frame construction: a) side frames
constructed form formed steel, b) spreader with structural angles, c)
side skirts as required, d) take-up screws located at the tail end of
conveyor, e) conveyor support legs fabricated from heavy shapes, f)
slider-bed conveyor shall be painted green; C) Steel belt conveyor --
1) Nominal dimensions: a) 6" pitch, b) belt width 48", b) belt path
style D @ 40 degrees, horizontal-inclined, c) horizontal projection
28'6" between centers of head and tail sprockets, d) vertical
projection 11'4" between centers of head and tail sprockets, e) lower
horizontal 12'0" approximate effective loading area, f) upper
horizontal 2'4", 2) Belting: a) 6" pitch hinged steel belt, 3) Drive:
a) minimum 1750 RPM electric motor, continuous duty, V-belt drive to
gear reducer with totally enclosed guard, 4) Frame: a) standard closed
panel frame, b) side panels from formed #7 gauged steel with enclosed
3/8" thick track. All field connections shall be bolted, c) conveyor
sides shall have two pairs of removable inspection panels, d) spreader
bottom pan: 5" structural channels bolted to side panels on 60"
centers, formed #11 gauge steel, on incline, e) side skirts 3/8" thick,
7" high on lower horizontal, and 7 gauge, 48" high on incline and upper
horizontal. Side skirts project below wing to provide seal, 5) Support
legs: a) fabricated from heavy shapes, b) belt adjustment screws
located at the head end of the conveyor, 6) Conveyor shall be painted
green; D) Sorting Platform -- 1) Sorting chutes: a) 4 ea. -- (2'6" X
3'6") dualoutfeed, 2 ea. -- (2'6" X 2'0") single outfeed, 2) Handrail
24" high, three rail, 2" round (removable), 3) 4" high steel toeplate,
4)Modular welded joist and beam construction, 5) Beams and floor
plates per AISC codes, 6) Diamond plate floor plates (approximately 420
sq. feet), 7) all connections bolted except decking and handrail, 8)
Stairs: a) 36" wide bolted bar grating treads(maximum 7" rise and 11"
run equally spaced), 9) Elevation 7'6" T.O.S., 10) all equipment
loading and 125 per sq. ft. live load. All clauses and provisions
remain in effect and unchanged. The closing date for this solicitation
is hereby extended to 26 May 2000, 3:00 p.m. PST. Responses from
responsible offerors and inquiries may be faxed to Bill Archambeault at
(619) 532-2575, or mailed to: Fleet & Industrial Supply Center San
Diego, 937 North Harbor Drive, Suite 212, Attn: Bill Archambeault-Code
2415, San Diego, CA, 92132-0060. Offerors MUST be registered with the
CENTRAL CONTRACTOR REGISTRATION. No phone calls, please. ****Note 1
Posted 05/11/00 (W-SN453827). (0132) Loren Data Corp. http://www.ld.com (SYN# 0241 20000515\35-0001.SOL)
35 - Service and Trade Equipment Index Page
|
|