COMMERCE BUSINESS DAILY ISSUE OF MAY 17,2000 PSA#2602Defense Distribution Center, Procurement Division, ATTN: DDC-AA, 2001
Mission Drive, Building 81, New Cumberland, PA 17070-5001 54 -- CONVEYOR SYSTEM SUPPORT STRUCTURES SOL SP3100-00-R-0020 DUE
063000 POC Joni Stephens, Contract Specialist Phone: 717-770-5912 FAX
717-770-5689 The Defense Distribution Depot San Diego, CA has a
requirement for a catwalk/conveyor support structure (CLIN 0001) and a
conveyor system support structure (CLIN 0002) to be located in Bldg.
3304A . Descriptions are as follows: CLIN 0001 The specification
defines the materials and equipment required to construct a
catwalk/conveyor system support structure. The structure shall consist
of approximately 370 linear feet by 11 feet of mezzanine structure,
two (2) stairways and associated decking, conveyor supports, handrails,
toeboards and other equipment necessary to satisfy the requirements of
the specification. The catwalk structure shall have a finished height
of 11 feet 6 inches measured from the dock elevation to the top of
decking. The contractor shall demolish and dispose of the existing
conveyor support structure. The contractor shall remove and replace
existing electrical conduit supports and air piping supports as
necessary. The finished product shall be designed to meet the
requirements of the Uniform Building Code for Seismic zone 4 to resist
lateral seismic forces without connection to the building structure
except for floor anchors. CLIN 0002 The specification defines the
materials and equipment required to construct a conveyor system support
structure. The component parts and materials shall be mechanically
interchangeable with the existing conveyor support structural system.
Existing system was originally manufactured by Fraser. The structure
shall consist of approximately 325 linear feet of mezzanine structure,
one stairway and associated decking, handrails, toeboards and other
equipment necessary to satisfy the requirements of the specifications.
The structure shall have a finished height of 15 feet, 1-1/4 inches
(floor to top of decking). The finished product shall be designed to
meet the requirements of the Uniform Building Code for Seismic zone 4
to resist lateral seismic forces without connection to the building
structure except for floor anchors. Interested contractors shall
request thesolicitation via FAX to Joni Stephens (FAX # 717-770-5689).
Requests must include: Company name, complete mailing address, phone
number, fax number and a point of contact. Posted 05/15/00
(W-SN454711). (0136) Loren Data Corp. http://www.ld.com (SYN# 0223 20000517\54-0001.SOL)