Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 2,2000 PSA#2613

Department of the Air Force, Air Combat Command, 4 CONS, 1695 Wright Brothers Ave, Seymour Johnson AFB, NC, 27531

35 -- SANDBLASTER AND ACCESSORIES SOL F31610-00-Q0345 DUE 062200 POC Brenda Russo, Superintendent/1st Sgt, Phone 919-722-5411, Fax 919-722-5403, Email brenda.russo@seymourjohnson.af.mil -- Maurice Edmondson III, Contract Specialist, Phone 919-722-5423, Fax 919-722-5424, Email WEB: Visit this URL for the latest information about this, http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=F31610-00-Q03 45&LocID=1004. E-MAIL: Brenda Russo, brenda.russo@seymourjohnson.af.mil. Contractor to provide an Empire Modular Sand Blaster part number 7272PRC-12 and accessories or equal at Seymour Johnson AFB, NC. Empire Modular Sand Blaster 7272PRC-12 or Equal to consisting of the Blast Cabinet, Reclaimer, and Dust Collector and accessories. The descriptions for each are as follows: Blast Cabinet: CONSTRUCTION: #11 gauge (minimum) continuos welded seams. SWING ACCESS DOOR: One swing open door on the right side of the cabinet, self adjusting door latch, poron gasket (1 inch square section). BLAST SAFETY INTERLOCK: OSHA approved preventing blast with open door. FLOOR: 1,500 lb. Capacity, 3/16_ thick, 2 piece perforated steel with protective edging and 12_ diameter holes. GLOVES: two, 8_ diameter felt lined rubber coated, height of glove openings adjustable. VIEWING WINDOW: Large 14_ X 22_ safety glass, quick-change knobs for easy replacement (no tools required), KleenSweep window with air wash for improved visibility. LIGHTING: Three 150-watts spotlights (450 W total), KleenSweep cools lights and interior. FOOT TREADLE: Pneumatic for operator safety, movable with toe guard. BLOWOFF GUN: For manual air washes of interior and work-piece, OSHA approved. DIMENSIONS: Outside: 72_ D X 72_ W X 82_ H; w/ Reclaimer: 101_ D X 72_ W X 94_H; Inside: 72_ D X 72_ W X 62_ H; Door Opening: 64_ W X 58_H. Reclaimer: CAPACITY: 900 CFM. PURPOSE: Centrifugally separates proper size media for refuse from undersized particles (dust) and oversized particles. Good media is automatically deposited into the storage hopper for refuse, improves blasting consistency and quality, improves operator_s visibility, fines are conveyed to dust collector and oversized particles are trapped on scalping screen. EFFICIENCY: 99.5% minimum. TUNABLE: Secondary air adjustment controls cutoff point between fines and good media. CONSTRUCTION: #12 gauge (minimum) continuos welded seams, screen access/media fill door: 6_ X 12_ with latch and gasket. SCALPING SCREEN: Removable for through cleaning, basket style for extended cleaning periods. PRESSURE POT: One cubic foot capacity, ASME coded and National Board registered. Automatic refill and exhaust. Patented Sure-Flo media regulator assures process media regulation and uninterrupted media flow. Dust Collector: MODEL: DCM-200A. PURPOSE: To ventilate blast cabinet for viewability and cleanliness. Provides energy to convey media to reclaimer for separation. Filters dust laden air and discharges clean air to shop, reducing heating and air conditioning costs. CONSTRUCTION: 14 gauge (minimum) continuos welded seams (door bolted and gasketed). Dust dump door: 4_ X 4_ with latch and hinge (gasketed). EFFICIENCY: 99.5% to one micron FILTRATION BAGS: 30 Cotton Sateen tubular bags. 6_ diameter by 58_ (6.67 sq. ft. each). BLOWER MOTOR: _Pull-Thru_ style- mounted on clean airside for impeller longevity. BAG SHAKER: Standard manual pneumatic shaker provided to clean bags. SOUND LEVEL: Without Optional Silencer: 76-79 DBA. SPECIFICATIONS: Blower Horsepower- 2; Std Electrical- 230/1/60; CFM at 6_ S.P.-900 (water); Air to Cloth ratio- 4.5:1; Cloth Area (sq. ft)- 200; Quantity bags- 30; Inlet diameter- 10_; Dimensions- 34_ D X 39_ W X 105_H Accessories are as follows: 1.) Heavy duty conveying hose, smooth I.D., heavy PVC Flexible hose for maximum hose life. 2.) Reclaim wear plate; an external, rubber backed steel plate that protects the reclaimer body from excessive wear at the media inlet. 3.) Manometer, a gauge that measures the pressure drop across the cartidges in the dust collector to determine the cleanliness of the cartides. 4.) 48_ manual turntable and dolly/track assembly arid pneumatic piston-lift hinged door that acts as turntable track when in open position. 5.) 3/16_ Di-Carb nozzle: for blasting with glass bead or steel abrasives. 6.) Boron restrictor for exhaust valve: assures longest life in interior of the exhaust valve where inspection of parts is more difficult. 7.) Sight plugs for pressure pot, allows operator to look inside pressure pot to check abrasive level, includes 2 8.) Static strap: wornon operator_s wrist to dissipate static charge when humidity is low. 9.) Upgrade to cdc-9 cartidge dust collector: the cdc-9 cartidge collector has two cartidfges with 452 square feet of filter area. Includes a 2hp blower motor, 230/60/1 electrical, manual reverse jet-pulse dust purging via push button, 16 gallon waste drum. 900 CFM at 6_ static pressure air to filter ratio 1.99 to 1. Dimensions: 40_ D X 35_ W X 126_ H 10.) Freight No Ozone Depleting Certification (ODC) required. The proposed contract is 100% set-aside for a small business concerns. It is anticipated that the solicitation will be issued electronically on or about 31 May 00 on the Government_s Electronic Posting System (EPS) at www.eps.gov. The closing date for proposals to this office is 22 June 2000. Paper copies are not available. You must register on that site in order to receive notification of changes to the solicitation. Please submit any questions regarding the solicitation in writing at the site visit. Include the following information with your request: (1) Company Name, (2) Point of Contact, (3) Phone and FAX Numbers, (4) E-mail Address, (5) Street Address with 9-digit Zip Code, and (6) Business Size Status. E-mail is the preferred method of providing this information. Note: Any prospective contractor must be registered in the Central Contract Registration (CCR) in order to be eligible for award. Registration requires applicants to have a DUNS number. Registering may take up to 3 weeks to process. Recommend registering immediately in order to be eligible for timely award. Point of Contact SSgt Jenifer Lash, Contract Administrator, Phone 919-722-5405, Fax 919-722-5403, Email jenifer.lash@seymourjohnson.af.mil Brenda S. Russo, Chief, Simplified Acquisitions Flight, Phone 919-722-5411, Fax 919-722-5414, Email brenda.russo@seymourjohnson.af.mil Email your questions to SSgt Lash at Posted 05/31/00 (D-SN460036). (0152)

Loren Data Corp. http://www.ld.com (SYN# 0187 20000602\35-0001.SOL)


35 - Service and Trade Equipment Index Page