Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 5,2000 PSA#2614

Fleet and Industrial Supply Center, Puget Sound, Bldg 467 W Street, Code 200 Bid Desk, Bremerton, WA 98314-0051

61 -- STATIC FREQUENCY CONVERTOR SOL N00406-00-R-5175 DUE 072400 POC Kevin Miller (360)476-7806 E-MAIL: Contract Specialist, kevin_r_miller@puget.fisc.navy.mil. Static Frequency Converters (SFC). capable of converting Type I, 60 hertz (HZ), 440 volts, 3-phase power as defined in MIL-STD-1399(NAVY) to 400 HZ power. Unit shall be designed so that each can be paralleled with an identical SFC with an output of 10KVA. Fuses shall be kept to a minimum consistent with protection of various components within the SFC. Circuitry shall be of solid state design. SFC shall use IGBT technology or newer. All electrical components including relays, switches and wiring shall conform to and be located in accordance with applicable NEMA, ANSI and NFPA standards for the intended application. A supply circuit disconnect device shall be provided and installed on the SFC. Main and auxillary control circuits shall operate on a circuit of 115 volts or less derived from isolation transformer(s) integral with the equipment. All exposed, non-current carrying metal parts on the SFC shall be maintained at common, zero ground potential. None of the primary circuits in the equipment shall beconnected to ground. Solid state design shall be employed throughout for electronic components. Performance requirements: a) The overall input/output efficiency at rated load shall be 70%. b) The SFC will provide MIL-STD 1399 (NAVY) Type I power within the following parameters: OUTPUT power- 120 V AC; NO OF PHASES- 3; TYPE OF CONNECTION- Delta; CONTINUOUS POWER OUTPUT RATING -- 5 k VA; OUTPUT FREQUENCY- 400 Hz. The SFC shall operate satisfactorily under any of the following conditions: a) Ambient Termperature Range- 0 to 55 degrees C; b) Ambient Humidity Range- 0 to 95% relative humidity. MAXIMUM dimension including required shock mounts and cable pull boxes: Height- 60"; Width- 24"; Depth 38" (with max service envelope of 57"). FIRST ARTICLE TESTS to include the following: a) vibration IAW MIL-STD-167; b) shock IAW MIL-S-901; c)Electromagnetic interference characteristics IAW MIL-STD-461; d) Ferrous Magnetic Field Test and Stray Magnetic Field Test; e) 250-hour life test. Production unit(s) tests to include Operational Test and Manufacturing Reliability Test. Data Items to be provided are: a) First Article Test PROCEDURES and REPORTS b) Production Test Procedures and reports, c) Engineering Drawings and Associated Lists (parts/tools); d) PTD documentation OR Standard Commercial Manuals if information contained within meets or exceeds the PTD requirements. It is the government's intent to purchase 1 ea First Article and a total quantity of 52 each over a period of 3 to 5 years. Exact quantities per year are not available at this time but will be stated in the RFP. Inspection at source, acceptance at destination, FOB Puget Sound Naval Shipyard, Bremerton WA 98314-5100. This is a 100%_Small Business Set-Aside NOTES: 1, 9, 12, 26 apply. All responsible sources may submit offer/bid which shall be considered by FISC Puget Sound. Telephone requests will not be honored. Fax requests will be accepted at (360)476-2931 or e-mailed to FISCPS_bid_officer@puget.fisc.navy.mil. Posted 06/01/00 (W-SN460691). (0153)

Loren Data Corp. http://www.ld.com (SYN# 0242 20000605\61-0002.SOL)


61 - Electric Wire and Power and Distribution Equipment Index Page