Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 7,2000 PSA#2616

Naval Air Warfare Center Aircraft Division, Contracts Department, Building 129-2, Highway 547, Lakehurst, NJ 08733-5083

48 -- TRAVERSE WINCH AND TAIL GUIDE WINCH (TOP AND BOTTOM) VALVES SOL N68335-00-R-0376 DUE 061900 POC Pearly A. Edwards (732) 323-5208 The Naval Air Warfare Center Aircraft Division Lakehurst intends to procure through full and open competition, replacements to the existing RAST System Traverse and Tail Guide Winch Pumps and Valves. Quantities required are: 4 each Traverse Pump, 8 each Tail Guide Pump, 6 each Traverse Winch Valve, Tail Guide Winch Valve Bottom and 6 each Tail Guide Winch Valve Top. A 100% option applies to each CLIN/part numbers. Bid samples will be required. The Traverse and Tail Guide Winch Pumps and Valves will be used for the Recovery Assist, Securing and Traversing (RAST) System. Recovery Assist Subsystem assists the helicopter to land safely on the flight deck. While hovering, the pilot lowers the messenger cable from the helicopter to the flight deck. Securing Subsystem secures the helicopter immediately upon landing and during traversing. Traversing Subsystem enables the helicopter to be safely transported between the flight deck and the hangar. Ideally, the replacement pumps and valves will be currently available, normally stocked, off-the-shelf items which conform to current, widely accepted industry standards. Seals, O-rings, etc., shall be commercially available and easily replaced using standard tools. Pumps requirements include: Continuous Operating Pressure shall be between 3000 and 3200 psi with a Continuous Motor Speed of 1800 rpm; Minimum Rated Flow Capacity (in gpm) for the Traverse Pump for each operational phase shall be: 3.8 to 4.9 for slow traverse, 9.0 to 10.0 for fast traverse and 0 for tail guide; Minimum Rated Flow Capacity (in gpm) for the TGW Pump for each operational phase shall be: 0 for slow traverse, 4.5 to 5.5 for fast traverse and 4.5 to 5.5 for tail guide; actual volumetric efficiency at 3000 psi and 1800 rpm shall be greater than 91%; operation Ambient Temperature Range of 0 to 50 degrees C (32 to 122 degrees F); shall be resistant to salt water; shall meet Grade B Shipboard Shock Requirements of MIL-S-901; shall meet Type I vibration requirements of MIL-STD-167-1; shall have a minimum Mean Time Between Failure (MTBF) of 11,000 hours; shall be compatible with hydraulic fluid conforming to MIL-H-17672 Military Symbol 2075TH (150 Viscosity Grade 32) operating within a temperature range of 126 to 150 degrees F and having a contamination level of NAS 1638 Class 10 or better; shall have a CCW (looking on driveshaft) Direction of Rotation. Valve requirements include: The valves shall be capable of operating within an ambient temperature range of 0 to 50 degrees C (32 to 122 degrees F) with a relative humidity of 95%; shall be resistant to salt water; shall meet the Grade B Shipboard Shock Requirements of MIL-S-901; shall meet the Type I vibration requirements of MIL-STD-167-1; shall be compatible with hydraulic fluid conforming to MIL-H-17672, Military Symbol 2075-T-H (ISO Viscosity Grade 32) i.e., 28.8-35.2 centistokes at 40 degrees C (104 degrees F) with fluid operating temperatures ranging from 0-160 degrees F and fluid cleanliness of NAS 1638 Class 8 (ISO Grade 17/14); should preferably utilize ANSI B93.7M-1986 (NFPA D08) mounting interface (see Figure 1); shall utilize 115 VAC, 60Hz electrical power and shall utilize continuous duty solenoids which are easily replaced. Interface with existing equipment requirements apply, as do space constraints. Integrated Logistics Support (ILS) applies. Complete requirements will be provided with the solicitation package. You may propose a price for either Pumps or Valves or both. Aperture cards on the existing Pumps and Valves will be provided for guidance in according with Export Control requirements. Your company is required to register with the United States/Canada Joint Certification Office before you may receive a copy of the solicitation. You can access the internet web site (http://www.dlis.dla. mil/ccal/) for DD Form 2345, Military Critical Technical Data Agreement form. Please see Note 8, of the Commerce Business Daily (CBD) to telephone information concerning DD Form 2345 (1-800-352-3572). Your company is also required to register with the Central Contractor Registration (CCR) Database. The internet web site is: (http://www.ccr.dlsc.dla.mil/ccrinq). It is mandatory to register with the CCR, as your DUNS (Data Universal Numbering System + 4 number) number and your company's CAGE (Commercial and Government Entity) code will be required to conduct business with the Department of Defense. The Naval Air Warfare Center Aircraft Division Lakehurst intends to procure through full and open competition, replacements to the existing RAST System Traverse and Tail Guide Winch Pumps and Valves. Quantities required are: 4 each Traverse Pump, 8 each Tail Guide Pump, 6 each Traverse Winch Valve, Tail Guide Winch Valve Bottom and 6 each Tail Guide Winch Valve Top. A 100% option applies to each CLIN/part numbers. Bid samples will be required. The Traverse and Tail Guide Winch Pumps and Valves will be used for the Recovery Assist, Securing and Traversing (RAST) System. Recovery Assist Subsystem assists the helicopter to land safely on the flight deck. While hovering, the pilot lowers the messenger cable from the helicopter to the flight deck. Securing Subsystem secures the helicopter immediately upon landing and during traversing. Traversing Subsystem enables the helicopter to be safely transported between the flight deck and the hangar. Ideally, the replacement pumps and valves will be currently available, normally stocked, off-the-shelf items which conform to current, widely accepted industry standards. Seals, O-rings, etc., shall be commercially available and easily replaced using standard tools. Pumps requirements include: Continuous Operating Pressure shall be between 3000 and 3200 psi with a Continuous Motor Speed of 1800 rpm; Minimum Rated Flow Capacity (in gpm) for the Traverse Pump for each operational phase shall be: 3.8 to 4.9 for slow traverse, 9.0 to 10.0 for fast traverse and 0 for tail guide; Minimum Rated Flow Capacity (in gpm) for the TGW Pump for each operational phase shall be: 0 for slow traverse, 4.5 to 5.5 for fast traverse and 4.5 to 5.5 for tail guide; actual volumetric efficiency at 3000 psi and 1800 rpm shall be greater than 91%; operation Ambient Temperature Range of 0 to 50 degrees C (32 to 122 degrees F); shall be resistant to salt water; shall meet Grade B Shipboard Shock Requirements of MIL-S-901; shall meet Type I vibration requirements of MIL-STD-167-1; shall have a minimum Mean Time Between Failure (MTBF) of 11,000 hours; shall be compatible with hydraulic fluid conforming to MIL-H-17672 Military Symbol 2075TH (150 Viscosity Grade 32) operating within a temperature range of 126 to 150 degrees F and having a contamination level of NAS 1638 Class 10 or better; shall have a CCW (looking on driveshaft) Direction of Rotation. Valve requirements include: The valves shall be capable of operating within an ambient temperature range of 0 to 50 degrees C (32 to 122 degrees F) with a relative humidity of 95%; shall be resistant to salt water; shall meet the Grade B Shipboard Shock Requirements of MIL-S-901; shall meet the Type I vibration requirements of MIL-STD-167-1; shall be compatible with hydraulic fluid conforming to MIL-H-17672, Military Symbol 2075-T-H (ISO Viscosity Grade 32) i.e., 28.8-35.2 centistokes at 40 degrees C (104 degrees F) with fluid operating temperatures ranging from 0-160 degrees F and fluid cleanliness of NAS 1638 Class 8 (ISO Grade 17/14); should preferably utilize ANSI B93.7M-1986 (NFPA D08) mounting interface (see Figure 1); shall utilize 115 VAC, 60Hz electrical power and shall utilize continuous duty solenoids which are easily replaced. Interface with existing equipment requirements apply, as do space constraints. Integrated Logistics Support (ILS) applies. Complete requirements will be provided with the solicitation package. You may propose a price for either Pumps or Valves or both. Aperture cards on the existing Pumps and Valves will be provided for guidance in according with Export Control requirements. Your company is required to register with the United States/Canada Joint Certification Office before you may receive a copy of the solicitation. You can access the internet web site (http://www.dlis.dla. mil/ccal/) for DD Form 2345, Military Critical Technical Data Agreement form. Please see Note 8, of the Commerce Business Daily (CBD) to telephone information concerning DD Form 2345 (1-800-352-3572). Your company is also required to register with the Central Contractor Registration (CCR) Database. The internet web site is: (http://www.ccr.dlsc.dla.mil/ccrinq). It is mandatory to register with the CCR, as your DUNS (Data Universal Numbering System + 4 number) number and your company's CAGE (Commercial and Government Entity) code will be required to conduct business with the Department of Defense. Posted 06/05/00 (W-SN461478). (0157)

Loren Data Corp. http://www.ld.com (SYN# 0228 20000607\48-0002.SOL)


48 - Valves Index Page