COMMERCE BUSINESS DAILY ISSUE OF JUNE 8,2000 PSA#2617FISC Norfolk Acq Group, Hampton Roads Detachment, 1968 Gilbert St.,
Suite 600, Norfolk, VA 23511-3392 59 -- ELECTRICAL EQUIPMENT; GAS CIRCUIT BREAKER,(SF6) 38KV, 3 PHASE,
1200AMP, 60HZ SOL N00189-00-T-H445 DUE 062200 POC David C. Zareczny,
Contracting Officer, Code 202A2A, (757) 443-1431 This is a combined
synopsis/solicitation for commercial items prepared in accordance with
the format prescribed in Subpart 12.6 of the FAR, as supplemented with
additional information included in this notice. This announcement
constitutes the request for quote for the required item. Proposals are
hereby requested under RFQ N00189-00-T-H445, a subsequent solicitation
document will not be issued. FISC Acquisition Department Norfolk
intends to purchase on a full and open competitive basis the following
item, (1) 2 Each, 38KV Gas Circuit Breaker, SF6, with the following
specifications; 3 Phase, 1200AMP, 60 HZ, for outdoor use on an
effectively grounded system with maximum line to line voltage of 38KV.
3-Pole gang tripping and closing. Sulfur hexafluoride (SF6) gas shall
be the Dielectric and interrupting medium. The breaker shall consist
of 3 separate chambers (1-per phase) containing the interrupter units,
which shall be mounted on a single support frame. The moving contacts
are operated by a spring mechanism. The 3-pole units shall have the
ability to monitor the integrity of the interrupter. The SF6
interrupters shall be constructed of an insulating double layer of
fiberglass and epoxy resin cylinder with internal surfaces protected
against the effects of decomposed SF6. The breaker is to shipped fully
assembled and tested with a positive gas pressure of (5PSI Gauge) SF6
gas shall be added Via a filling valve as a part of the on site
installation. Data for 38KV dead tank SF6 gas circuit breaker-type 38
PM 40-12 or DT1-72.5F1. Breaker ratings and characteristics: Impulses
withstand voltage, Bil 200KV, low frequency withstand voltage 80KV, Ten
second wet test 75KV, chopped wave, 2U-SEC. Withstand 258KV, chopped
wave, 3U-SEC. Withstand 230KV, voltage range factor 1.0. Max.
symmetrical interrupting current 40KA symmetrical I.C. at Max. Voltage
40KA, 3-second current 40KA, close and latch current 64KA, Ratio, S,
of asymmetrical to sysmmetrical-1.05, interrupting time 3/5 cycle,
closing time 6 cycles, permissibletripping delay 2 seconds, continuous
current rating 1200AMPS, spring type operating mechanism typical duty
cycle 0-CO-15 SEC-CO-15 SEC-CO Adjust. Reclosing time, optional 15-120
cycles charging motor, max.current at 240VAC 10AMPS, standard creep
bushings, with porcelain watershed. Charging motor 1.25 HP, trip coil
current at 125VDC 15AMPS, Close coil at 125VDC 15AMPS, Space Heaters,
Control Cabinet 25W, SF6 Gas System, Rated operating pressure at 70 F,
65 PSIG, Min Operating Pressure for rated interruption at 70 F 50
PSIG, weight of SF6 gas 25lbs, This equipment must meet the performance
requirements of and be designed manufactured and tested IAW ANSI
C37.04, C37.06, and C37.09. Each breaker shall have 12 Each (2 per
Bushing) Multi-Ratio current transformers 1200/5 AMP accuracy class 200
(For Outdoor Use). Mfgr by Alstom, or Equal.. Delivery will be 60
Days/ARO or sooner. FOB Point is Destination to Norfolk, VA 23511.
Offers other than FOB Destination shall be ineligible for the award.
The following FAR provisions and clauses apply to this solicitation and
are incorporated by reference: FAR 52.212-1 Instructions to
Offerors-Commercial Items (MAR 2000), FAR 52.212-3 Offeror
Representations and Certifications-Commercial Items ( FEB 2000), FAR
52.212-4 Contract Terms and Conditions-Commercial Items (MAY 1999), FAR
52.212-5 Contract Terms and Conditions Required To Implement Statutes
or Executive Orders (FEB 2000), FAR 52.215-5 Facsimile Proposals (OCT
1997), FAR 52.232-33 Payment By Electronic Funds Transfer-Central
Contractor Registration (MAY 1999). The RFQ document,
(N00189-00-T-H445), provisions and clauses which have been incorporated
are those in effect through FAC 97-17. The following Defense FAR
Supplement (DFAR) provisions and clauses apply to this solicitation and
are incorporated by reference, with the exception of DFAR 252.204-7004
which will be in full text. DFAR 252.225-7000 Buy American Act
-Balance of Payments Program Certificate (SEP 1999), DFAR 252.212-7001
Contract Terms and Conditions Required To Implement Statutes or
Executive Orders Applicable to Defense Acquisitions of Commercial Items
(MAR 1998):The following clause under paragraph (b) of this clause
apply, DFAR 252.225-7001 Buy American Act and Balance of Payments
Program (MAR 1998), DFAR 252.204-7004, (MAR 2000), Required Central
Contractor Registration, (a) Definitions. As used in this clause -- (1)
"Central Contractor Registration (CCR) database" means the primary DOD
repository for contractor information required for the conduct of
business with DOD. (2) "Data Universal Numbering System (DUNS) number"
means the 9-digit number assigned by Dun and Bradstreet Information
Services to identify unique business entities. (3) "Data Universal
Numbering System +4 (Duns+4) number" means the Duns number assigned by
Dun and Bradstreet plus a 4-digit suffix that may be assigned by a
parent (controlling) business concern. This 4 digit suffix may be
assigned at the discretion of the parent business concern for such
purposes as identifying subunits or affiliates of the parent business
concern. (4) "Registered in the CCR database" means that all mandatory
information, including the DUNS number or the Duns +4 number, if
applicable, and the corresponding Commercial and Government Entity
(CAGE) code, is in the CCR database; the DUNS number and the CAGE code
have been validated; and all edits have been successfully completed.
(b) (1) By submission of an offer, the offeror acknowledges the
requirement that a prospective awardee must be registered in the CCR
database prior to award, during performance, and through final payment
of any contract resulting from this solicitation, except for awards to
foreign vendors for work to be performed outside the United States.(5)
The offeror shall provide its DUNS or, if applicable, its DUNS +4
number with its offer, which will be used by the Contracting Officer to
verify that the offeror is registered in the CCR database. (6) Lack of
registration in the CCR database will make an offeror ineligible for
award. (7) DOD has established a goal of registering an applicant in
the CCR database within 48 hours after receipt of a complete and
accurate application via the Internet. However, registration of an
applicant submitting an application through a method other than the
Internet may take up to 30 days. Therefore, offerors that are not
registered should consider applying for registration immediately upon
receipt of this solicitation. (c) The contractor is responsible for the
accuracy and completeness of the data within the CCR, and for any
liability resulting from the Government's reliance on inaccurate or
incomplete data. To remain registered in the CCR database after the
initial registration, the contractor is required to confirm on an
annual basis that its information in the CCR database is accurate and
complete. (d) Offerors and contractors may obtain information on
registration and annual confirmation requirements by calling
1-888-227-2423, or via the Internet at http://www.ccr2000.com. At a
minimum, responsible sources should provide this office: a price
proposal on letterhead or a SF1449 for the requested item, with unit
price, extended price, prompt payment terms, remittance address, Tax
I.D. #, Duns #, Cage code, and a completed copy of FAR 52.212-3. Award
will be made to the eligible, responsible offeror whose offer conforms
to the solicitation, and is the most advantageous in price to the
government. Responses to this solicitation are due by June 22, 2000.
Offers can be faxed to (757-443-1389/1333) or mailed to; Acquisition
Department, Fleet & Industrial Supply Center, 1968 Gilbert St., Suite
600, Attn: David C.Zareczny, Code 202A2A, Norfolk, VA.23511-3392.
Reference RFQ N00189-00-T-H445 on your proposal. Posted 06/06/00
(W-SN462008). (0158) Loren Data Corp. http://www.ld.com (SYN# 0249 20000608\59-0007.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|