Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 9,2000 PSA#2618

US Army Tank -- Automotive and Armaments Command -- Rock Island( TACOM-RI) Attn: AMSTA-CM-CR, Rock Island, IL 61299-7630

61 -- DC POWER SUPPLY SOL Market research for DC Power Supply POC Contract Specialist: Jeff DeVilder (309)782-6329 This activity is seeking information from companies that may be able to provide a commercial or existing DC Power Supply. This is not a request for quotes, but market research only. The following is/are the list of requirements for this Power Supply: POWER SUPPLY SPECIFICATIONS INPUT 105 -- 125 V. AC. 60 Hz. SINGLE PHASE OUTPUT 0 -- 32 V. DC. (MIN). CONTINUOUSLY VARIABLE. 0 -- 15 A. DC. (MIN). 480 WATTS (MIN). 0.75 % MAX RIPPLE 0.4 V/A VOLTAGE REGULATION FRONT PANEL REQUIREMENTS POWER ON/OFF SWITCH OR CIRCUIT BREAKER POWER ON INDICATION LIGHT OUTPUT VOLTAGE CONTROL OUTPUT AMMETER, + 2% ACCURACY OUTPUT VOLTMETER, + 2% ACCURACY OUTPUT TERMINALS -- POSITIVE AND NEGATIVE PHYSICAL CHARACTERISTICS SIZE -- HEIGHT X WIDTH X DEPTH 12 X 20 X 20 INCHES MAX. WEIGHT -- 90 LBS. MAX. TESTING REQUIREMENTS OPERATING TEST. WITH APPROPRIATE LOAD APPLIED, ADJUST OUTPUT VOLTAGE AND CURRENT WITH PANEL CONTROLS SO THAT PANEL METERS READ RESPECTIVELY. ATTACH 1/2 PERCENT ACCURACY VOLTMETER AND AMMETERTO OUTPUT TERMINALS. THE READING ON THE PANEL METERS SHALL BE WITHIN + 2 PERCENT OF THE APPLICABLE VOLTAGE AND CURRENT ON THE TEST METERS. VOLTAGE RIPPLE. AT FULL LOAD CONDITIONS, PLACE AN OSCILLOSCOPE ACROSS THE OUTPUT TERMINALS AND DETERMINE THE VOLTAGE RIPPLE. VOLTAGE REGULATION. USING A VOLTMETER HAVING AN ACCURACY OF 1/2 PERCENT, MEASURE THE OUTPUT AT NO LOAD CONDITIONS AND AT FULL LOAD CONDITIONS AND DETERMINE THE PERCENT CHANGE BETWEEN NO LOAD AND FULL LOAD CONDITIONS. OVERLOAD. APPLY A SHORT CIRCUIT ACROSS OUTPUT TERMINALS WHEN THE POWER SUPPLY IS BEING OPERATED AT FULL RATED OUTPUT. SUBSEQUENT TO THE TEST, THE POWER SUPPLY SHALL BE INSPECTED FOR DAMAGE AND MEASUREMENTS SHALL BE MADE TO DETERMINE CONFORMANCE WITH OUTPUT SPECIFICATIONS. Interested sources are encouraged to submit the following written information at NO COST or obligation to the Government: Name, address, point of contact and telephone number, description of components, and any brochures/literature. Responses should provide information regarding the experience of your company with the item, dimensional characteristics, and any test data. Any information received as a result of this announcement will not be provided to other contractors and may be utilized for the purposes of obtaining samples for test and evaluation. Send responses to: TACOM-ARDEC, ATTN: Mr. James Brinkley, AMSTA-LC-CTT-C, Rock Island, IL. 61299 telephone: (309) 782-1170. This notice is strictly for informational purposes. Posted 06/07/00 (W-SN462415). (0159)

Loren Data Corp. http://www.ld.com (SYN# 0265 20000609\61-0004.SOL)


61 - Electric Wire and Power and Distribution Equipment Index Page