|
COMMERCE BUSINESS DAILY ISSUE OF JUNE 15,2000 PSA#2622Naval Surface Warfare Center, Code 1163, 300 Highway 361, Crane, IN
47522-5001 16 -- CENTER CONDUCTOR SOL N00164-00-Q-0162 DUE 062900 POC Ms. Diane
L. Pearson, Code 1163W7, telephone 812-854-5201, FAX 812-854-3805;
Luann Shelton, Contracing Officer WEB: click here to download copy of
RFQ, http://www.crane.navy.mil/supply/announce.htm. E-MAIL: click here
to contact via e-mail, pearson_d@crane.navy.mil. This is a combined
synopsis/solicitation for noncommercial items prepared in accordance
with the format in FAR Subpart 13, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; proposals are being requested and a written
solicitation will not be issued. Solicitation number N00164-00-Q-0162
applies and is issued as a request for quotation (RFQ). In accordance
with FAR 19.502(a), the Contracting Officer has dissolved the small
business set-aside and this requirement is unrestricted. This
solicitation document and incorporated provisions and clauses are those
in effect through Federal Acquisition Circular 97-17 and DCN 2000522.
The standard industrial code is 3499 and the business size standard is
500 employees. This requirement is as follows: CLIN 0001 -- 50 each
Center Conductor Fabrication in accordance with Raytheon Drawing
#444408-1. The following is a brief description of the requirements
associated with the fabrication: Gold plate .0002 thick per
MIL-E-45204, Type III, GR A, CL 3 with the following exception to
paragraph 6.3 of MIL-G-452041, Nickel or silver strikes or underplate
shall not be used. Bake per MIL-G-45204 para 4.5.2.3. Heat treat per
MIL-H-7199 after brazing and prior to plating. Use controlled
atmosphere to prevent surface finish deterioration, only item 5 must be
temper H. Assy shall have No. indication of leakage when air pressure
tested at 150 PSI. CLIN 0002 10 each Line Sections Fabrication in
accordance with Raytheon Drawing #1037586-1. The following is a brief
description of the requirements associated with the fabrication:
Interpret drawing per DOD-D-1000. Maintain sharp edges on inside DIA
and break sharp edges outside 0.15 max. Surface texture per ANSI B45.1.
Chemical film per MIL-C-5541, CL 3. Mark .09 nominal high
characteristics including part REV letter approx as shown using
contrasting color ink Per 152505. Alternate construction: braze per
MIL-B-7883, type V, Grade B. Braze joints shall not break into central
1.524 1.530 DIA bore. All dimensions apply after plating. CLIN 0003 10
each Line Section Fabrication in accordance with Raytheon drawing
#1037587-1. The following is a brief description of the requirements
associated with the fabrication: Material AL ALY 6061-T6 Per
QQ-A-225/8. Finish Chemical film per MIL-C-5541, CL 3. Break sharp
edges 0.10 Max. Surface texture per ANSI B46.1 Screw threads per
MIL-S-7742. All interested companies shall request drawing package by
sending an e mail to pearson_d@crane.navy.mil All drawing packages must
be requested no later than 21 June 00 to ensure adequate time to review
drawings. Delivery is required F.O.B. Crane, IN 47522 within 90 days
after award. Final inspection will be at NSWC Crane. Selection for
award will be based on past performance and price. Quotes that are
non-compliant with any material requirement of this solicitation may be
rejected without further consideration for award. All responsible
sources may submit a quote that will be considered by the Agency. A
Firm-Fixed Price purchase order will be awarded using Simplified
Acquisition Procedures. The following provisions and clauses apply:
52.204-6; 52.207-4 [FILL-IN]; 52.209-6; 52.211-5; 52.211-14 (DO);
52.211-15; 52.213-4; 52.219-1 [FILL-IN]; 52.213-4 (incorporating
52.247-34); 52.222-21; 52.222-22; 52.222-25 [FILL-IN]; 52.232-23;
52.242-15; 52.242-17; 52.243-1; 52.246-1; 52.246-16; 52.249-1;
52.249-8; 52.252-2; 52.253-1; 252.204-7001; 252.204-7003; 252.204-7004;
252.225-7000; 252.225-7001; 252.225-7002; 252.225-7017; 252.225-7009;
252.225-7017; 252.225-7035; 252.225-7036; 252.243-7001; 252.246-7001;.
Please provide your Commercial and Government Entity (CAGE) code and
Contractor Establishment Code (DUNS number). To be eligible for award
you must be properly registered in the Government's Central Contractor
Registration (CCR). Offerors may obtain information on CCR
registration and annual confirmation requirements by calling
1-888-227-2423, or via the Internet @ http://ccr.dlsc.dla.mil or
www.ccr2000.com. If a change occurs in this requirement, only those
offerors that respond to this announcement within the required time
frame will be provided any changes/amendments and considered for future
discussions and/or award. Quotations may be faxed or e-mailed to Diane
L. Pearson, FAX 812-854-3805, e-mail address pearson_d@crane.navy.mil
All required information must be received on or before 29 June at 1200
Eastern Standard Time. See Note 26. Posted 06/13/00 (W-SN464192).
(0165) Loren Data Corp. http://www.ld.com (SYN# 0178 20000615\16-0003.SOL)
16 - Aircraft Components and Accessories Index Page
|
|