COMMERCE BUSINESS DAILY ISSUE OF JUNE 22,2000 PSA#2627Dept. of Veterans Affairs Medical Center, 10000 Brecksville Road,
Brecksville, OH 44141 65 -- CAPILLARY HIGH PERFORMANCE LIQUID CHROMATOGRAPH (HPLC) DUE
062300 POC Danny O. Freeman, Contracting Officer, (440) 838-6091 The
Louis Stokes Cleveland VA Medical Center is seeking sources that can
provide a Magic 2002 HPLC Unit (stk #602/00000/00)(qty 1 ea), for
sensitive detection of very small quantities of sample materials for
qualitative characterization experiments. This system includes a
capillary flow range kit (stk #602/33004/02)(qty 1 ea); Magic
temperature control autosampler (stk #101/00002/00)(qty 1 ea); Magic
HPLC Xcalibur Control System (stk #602/20007/00)(qty 1 ea); 718A/S 96
Well Autosampler tray (stk #101/25003/00)(qty 1 ea); 0.2x150 mm VYDAC
C18 MS Column 5u 300A (stk #902/31261/00)(qty 1 ea); Small Molecule
Captrap 6 PK (stk #004/25109/31)(qty 1 ea); Peptide Captrap, 6 PK (stk
#004/25109/32)(qty 1 ea); Protein Captrap (stk #004/25108/33)(qty 2
ea); Manual Captrap Holder Kit (stk #602/25029/03)(qty 1 ea); Manual
Micro Trap Holder Kit (stk #004/25111/01)(qty 1 ea); Valco Micro/Macro
Trap Loop Holder (stk #004/25110/00)(qty 1 ea); SDS Removal Microtrap
(stk #004/25108/04)(qty 3 ea); Nid Removal Microtrap (stk
#004/25108/07)(qty 1 ea); Small Molecule Micro Trap (stk
#004/25108/01)(qty 3 ea); Peptide Microtrap (stk #004/25108/02)(qty 3
ea); 10-32 Male/Male Union (stk #004/25086/00)(qty 1 ea). VA requires
a Capillary High Performance Liquid Chromatograph (HPLC) which is
compatible for use with a Finnigan LCQ Decca quadrupole ion trap mass
spectrometer. The mass spectrometer and the Capillary HPLC together
constitute on instrument system. Systems of equal must meet the
following design criteria: The Capillary HPLC machine must be capable
of performing reproducible gradient separations at flow rates equal to
or less than one microliter per minute. The capillary HPLC machine
must be controlled by the ion trap mass spectrometer's control
software. This is a request for product information and sources only!
This is not a request for proposal (RFP). The VA does not intend to pay
for information received. Requests for copies of a solicitation shall
not be honored or acknowledged. Information should be forwarded to the
Contracting Officer by June 23, 2000. VA shall review all information
to determine the availability of similar available capillary HPLC
systems. Systems must meet the above criteria and be compatible to the
VA owned systems mentioned herein. Should you have questions, you may
contact the Contracting Officer at the number provided. Posted
06/20/00 (W-SN466478). (0172) Loren Data Corp. http://www.ld.com (SYN# 0238 20000622\65-0008.SOL)
65 - Medical, Dental and Veterinary Equipment and Supplies Index Page
|
|