Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 26,2000 PSA#2629

Contracting Officer (90C), Department of Veterans Affairs, North Texas Health Care System, 4500 South Lancaster Road, Dallas, TX 75216

65 -- RECESSED PATIENT WALL STATIONS SOL 549-68-00 DUE 071100 POC Belinda L. Cook, 214-857-0037 Send completed Quotations referring the solicitation number with attention to Contracting Officer to: VA North Texas Health Care System located at 4500 S. Lancaster Rd., Dallas, TX 75216, here in after referred to as VANTHCS contemplates the purchase of a Medical Solutions International or equal (1) Bicarb Mixing and Distribution and Acid Distribution Systems for Hemodialysis. The successful offeror shall be required to provide; (1) FOB destination delivery, (2) three of each operating and service manual; (3) "on-site" system training; (4) Installation; (5) and a full year parts and labor warranty to include a preventive maintenance and emergency repair system at no extra cost to VANTHCS. The product must meet the minimum salient characteristics as defined in this solicitation. Each offeror shall be required to provide descriptive literature with his/her offer. GENERAL MINIMUM SPECIFICATION Bicarb Mixing andDistribution and Acid Distribution Systems for Hemodialysis Consisting of: (1 Each) Bicarbonate mixing and distribution system to service 27 patient stations. (2 each) Acidified concentrate distribution system to service 27 patient stations. (2 Each) 300 gallon acid storage tanks The system must have the capability of easy sanitation and clean up. The system must be low pressure 2 PSI at each station to accommodate Fresenius 2008H dialysis equipment with a flow rate of 800ml/min (gravity or pump fed with backup pump in line). All pumps must be backed up with redundant pumps to insure any pump malfunction may be back on line within five minutes. Recessed patient walls stations to house two each acid connectors and one each bicarb connector A 800 ml min dialysate flow at each 2008H Fresenius machine Bicarb flow rate 1 oz per minute per machine Acid flow rate 1 oz per minute per machine All plumbing, pumps, regulators, monitors, values and returns must be installed by the vendor. Electrical and any core drilling will be performed by our Engineering Department. All Quotations will be reviewed by VA Technical Representative to determine if minimum specification have been met. Award will be made to the lowest priced offer meeting all requirements of this Quotation. Line Product Description QTY UN Unit Total Item Cost Cost 1. Recessed Patient Wall Stations 30 Ea. $ $ 2. Bicarbonate Valving 30 Ea. 3. Acidified Valving 60 Ea. 4. End Point Interface Fitting 90 Ea. 5. Coiled Concentrate Tubing Lines 60 Ea. 6. Bicarbonate Mixing and Distribution System 1 Ea. 7. Acidified Distribution System 1 Ea. 8. Acidified Bulk Storage Tanks 3 Ea. 9. Concentrate Loops (3 Each 700 Foot Loops) 3 Ea. Bidding On: Manufacturer name_________________________________________________ Brand Name & Product No.__________________________________________ Posted 06/22/00 (W-SN467475). (0174)

Loren Data Corp. http://www.ld.com (SYN# 0278 20000626\65-0001.SOL)


65 - Medical, Dental and Veterinary Equipment and Supplies Index Page