COMMERCE BUSINESS DAILY ISSUE OF JUNE 27,2000 PSA#2630U.S. Environmental Protection Agency, 26 W. Martin Luther King Dr.,
Cincinnati, OH 45268 99 -- DESIGN, BUILD, AND INSTALL AN AIR POLLUTION CONTROL SYSTEM SOL
PR-CI-00-10894 POC Andre Reinhart ph: (513)487-2119 e-mail:
reinhart.andre@epa.gov WEB: Click here to download a copy of the draft
statment, http://www.epa.gov/oam/cinn_cmd/. E-MAIL: Click here to
contact the contracting officer via, reinhart.andre@epa.gov. The
Environmental Protection Agency's National Risk Management Research
Laboratory (EPA/NRMRL) has a requirement for a contractor to design,
build, and install an Air Pollution Control System (APCS) in the
permitted Hazardous Waste Incineration Research Facility, operated by
NRMRL's Air Pollution Prevention and Control Division (APPCD) in
Research Triangle Park, North Carolina. The APCS will collect or
destroy pollutants generated by four research combustors used by the
facility. The major components of the APCS are 1) A natural gas-fired
afterburner, which is used to destroy/oxidize compounds generated
during research testing 2) A flue gas quench system used to cool the
gas to a temperature that the downstream equipment can handle; 3) A
fabric filter (baghouse) used to remove 99% of any solid particles that
have been produced by the research combustors and afterburner; and 4)
An acid gas scrubber used to remove 95% of acid gases generated in the
research combustors and afterburner. Interested parties are requested
to submit to the Contracting Officer a capability statement that
includes: (1) Name of firm, mailing address, point of contact's phone
number and e-mail address. (2) Standard Industrial Classification (SIC)
Code that best describes the firm's business and whether the firm is a
large or small business under that code. (3) Whether the firm is a
small disadvantaged business and/or woman-owned business. (4) A brief
statement of experience/qualifications to design, build, and install an
Air Pollution Control System. The draft Statement of
Work/specifications will be posted to the following website no later
than June 30, 2000: http://www.epa.gov/oam/cinn_cmd/ Comments on the
document are requested to be sent to the Contracting Officer. E-mail is
the preferred method of receipt for capability statements and comments
on the draft statement of work (reinhart.andre@epa.gov), and are both
are requested to be submitted no later than July 24, 2000. NO
SOLICITATION DOCUMENT IS CURRENTLY AVAILABLE. Posted 06/23/00
(W-SN468158). (0175) Loren Data Corp. http://www.ld.com (SYN# 0299 20000627\99-0006.SOL)
99 - Miscellaneous Index Page
|
|