COMMERCE BUSINESS DAILY ISSUE OF JUNE 27,2000 PSA#2630USAED, Walla Walla, ATTN: CENPW-CT, 201 North Third Avenue, Walla
Walla, WA 99362-1876 Z -- MILL CREEK DIVERSION AND INTAKE STRUCTURE MODIFICATIONS, WALLA
WALLA COUNTY, WALLA WALLA, WASHINGTON SOL DACW68-00-B-0041 DUE 082200
POC To order a CD, interested firms may either (1) fax requests,
complete with company information, shipping address, point of contact,
phone number, fax number, and business size, to Barb Hackett at
509/527-7802, (2) email requests, containing all information, to the
address below, or (3) register via the Walla Walla District's Web Page
at the URL listed below. WEB: Advertised Solicitations,
http://www.nww.usace.army.mil/ebs/asp/advertisedsolicitations.asp.
E-MAIL: Lower Granite Prototype Oil-Skimmer Installation,,
barbara.a.hackett@usace.army.mil. THIS PROCUREMENT IS 100% SET ASIDE
FOR HISTORICALLY UNDERUTILIZED BUSINESSES (HUBZone). SOLICITATION
DOCUMENTS, INCLUDING DRAWINGS, WILL BE AVAILABLE ON CD ONLY. The work
will consist of furnishing and installing an oil-skimmer assembly at
Lower Granite Dam on the Snake River. The components of the oil-skimmer
consist of a motor driven belt and scraper assembly. The belt is 8
inches wide extending approximately 60 feet below the motor drive.
Ancillary equipment associated with the oil-skimming system consists of
a decanter, storage drum, drum pump and float gauge. In addition a
skimmer system for the draft tubes shall be provided, consisting of a
skimmer head, diaphragm pump, separator and oil recovery tank. A
portable separation unit capable of separating oil and water mixtures
at a flow rate of 10 gpm shall also be provided. Steel pipe from
14-inch to 4-inch diameter in various lengths and configurations is
required. Smaller diameter PVC and vinyl piping is required to complete
the oil-skimmer assembly. Structural steel fabrication of supports,
inlet baffle, and access hatch is required. Steel parts require hot-dip
galvanizing. Mechanical equipment includes floats, valves, pumps, speed
reducers, and other items associated with the oil-skimmer assembly.
Electrical equipment includes motors, starters and associated controls,
cabinets and boxes, conduits, wires and cables, control panels,
alarming, and other items. Concrete work includes core drilling a
42-inch diameter access hole in a 36-inch floor slab and core drilling
for a 2-inch conduit in 6- and 8-inch concrete walls and ceilings.
Adhesive grout is required to secure an access hatch. The estimated
cost range for this job is between $100,000 and $250,000. The standard
industrial classification code (SIC) is 1629. The current small
business size standard are average annual receipts for the previous
three fiscal years must not exceed $17.M. NOTE: Solicitations issued on
or after July 17, 2000 will reflect new standards in accordance with
Small BusinessAdministration 13 CFR Part 121 dated June 16, 2000.
http://www.sba.gov/news/indexwhatsnew.html All responsible certified
HUBZone small business sources may submit an offer, which may be
considered. Posted 06/23/00 (W-SN468034). (0175) Loren Data Corp. http://www.ld.com (SYN# 0146 20000627\Z-0004.SOL)
Z - Maintenance, Repair or Alteration of Real Property Index Page
|
|