COMMERCE BUSINESS DAILY ISSUE OF JULY 31,2000 PSA#2653 DOE/National Energy Technology Laboratory, P.O. Box 10940, MS 921-107,
Pittsburgh, PA 15236-0940 44 -- LARGE DIAMETER VERICAL FURNANCE WITH CLOSED BOTTOM END AND THREE
INDEPENDENTLY-CONTROLLED HEARING ZONES. SOL DE-RQ26-00NT000673 DUE
081800 POC Thomas J. Gruber -- 412.386.5897 E-MAIL:
thomas.gruber@netl.doe.gov, thomas.gruber@netl.doe.gov. This is a
combined synopsis/solicitation for commercial items prepared in
accordance with the format in Subpart 12.6, as supplemented with
additional information included in this notice. The announcement
constitutes the only solicitation: proposals are being requested and a
written solicitation will not be issued. This solicitation document
incorporates all provisions and clauses in effect through Federal
Acquisition Circular 97-11. The solicitation number is
DE-RQ26-00FTS00673 and is being issued, on July 28, 2000, as a Request
for Quotations using Simplified Acquisition Procedures under FAR Part
13. Only written offers received by Aug 18, 2000 in accordance with
the solicitation, will receive consideration and responses must convey
the ability of the offeror to meet the stated requirements. The
documentation shall include descriptive literature containing
sufficient technical literature to establish a bonafide capacity of
meeting this requirement. Request for information should be directed to
Thomas J. Gruber at 412-386-5897 or E-mail thomas.gruber@netl.doe.gov.
FURNACE SPCIFICATIONS Large diameter vertical furnace with a closed
bottom end and three, independently controlled heating zones. Typical
operating temperature range is 300 deg C to 1000 deg C. Furnace must be
able to maintain temperature when a particle-laden gas stream is
introduced into a customer-supplied stainless steel closed retort
positioned inside the furnace. The retort will be approximately 12 3/4"
diameter and 32 " high, with the top several inches extending out of
the furnace. The gas stream will not exceed 5 liters per min during
operation. Inside heated dimensions are 13 1/2" to 16" diameter and a
minimum of 30" length. Outside dimensions are approximately 24" OD x
36" L x 35" D x 42" H, furnace must be able to go through a standard
36" door. Power supply will be of three zone design and consist of
three Honeywell UDC 3300 microprocessor based controllers tied in with
three independent SCR power controllers (or equivalent controllers and
SCR supplies). Thermocouples must be "N" or "K" type and system must
include all necessary switches, relays, etc. to allow turn-key
operation following power hook-up on delivery. Outside shell shall be
heavy gauge steel with block graded high purity fibrous alumina
insulation. Heating elements must be Kanthal A1 wire embedded in half
round, replaceable, ceramic plate heaters. The furnace MUST be rated
for 25 to 28 KW, with 440 volt, 3-phase, 60 Hz service." Posted
07/27/00 (W-SN479296). (0209) Loren Data Corp. http://www.ld.com (SYN# 0247 20000731\44-0002.SOL)