COMMERCE BUSINESS DAILY ISSUE OF AUGUST 7,2000 PSA#2658 National Institute of Diabetes, Digestive & Kidney Diseases (NIDDK),
Acquisition Management Branch, 6705 Rockledge Dr., MSC 7973, Room 8048,
Bethesda, Maryland 20892-7973 66 -- RADIO FREQUENCY POWER AMPLIER SOL NIH-NIDDK-00-577 DUE 083000
POC Dessree Kelly, Purchasing Agent 301-594-7731 The National
Institutes of Health (NIH) National Institute of Digestive and Kidney
Diseases (NIDDK) has a requirement to purchase a Radio-Frequency power
amplifier. The required specifications must be met: 1) the power
amplifier must provide pulse powers of at least 600 watts, with pulse
lengths of at least 100 milliseconds. 2) The amplifier must be capable
of a 10% duty cycle at full output power. 3) The amplifier must
provide linear amplification with a gain of at least. 4) Pulse rise and
fall times must be less than 300 nanoseconds 5) The amplifier must
cover the frequency range from 550 MHz to 610 6) The amplifier must
have output blanking controlled by a TTL level with switching times
less than 2 microseconds. 7) Pulse amplitude droop at full output power
must less than 8% for a 20 millisecond pulse. The Institute intends to
obtain the scientific equipment by full and open competition. The
Standard Industrial Classification Code is 3821 and the business size
is 500. All responsible business sources may submit a quotation, which
if timely received, shall be within the Simplified Acquisition
Threshold for Purchases up $ 100,000. It is the intent of the National
Institute of Diabetes and Digestive and Kidney Diseases to purchase
the required equipment specified in the Request for Quote (RFQ).
Vendors capable of furnishing the Government this equipment should
request a copy of the Request for Quote form from the above contact. It
is anticipated that Request for Quotation (RFQ) NIH-NIDDK-00-577 will
be available fifteen (15) days after the publication date of this
synopsis. Receipt of quotations will be due ten (10) days after the
release of the RFQ. The anticipated award date is August 30, 2000.
Request for copies must be in writing and may be FAX to 301-480-4226.
Quotations must be submitted to the National Institute of Diabetes and
Digestive and Kidney Diseases Room: 6705 Rockledge Drive, Room 8048,
Bethesda, MD 20817 Attention: Desiree Kelly FAX quotations must contain
offerors signed by an authorized company representative. Posted
08/03/00 (W-SN481971). (0216) Loren Data Corp. http://www.ld.com (SYN# 0364 20000807\66-0011.SOL)
| 66 - Instruments and Laboratory Equipment Index
|