Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF AUGUST 11,2000 PSA#2662

Procurement Division, Naval Air Station Oceana, Supply Dept. Bldg 730, Virginia Beach, VA 23460-5120

41 -- AIR COOLED ROTARY CHILLER TRANE MODEL #RTAA-125 OR APPROVED EQUAL SOL N60191-00-Q-0005 DUE 082500 POC Lou Hemmings 757-433-3442 E-MAIL: Lou E Hemmings, 757-433-3442 fax 2176, hemmingsl@nasoceana.navy.mil. RSO Oceana in Virginia Beach, VA is issuing Solicitation # N60191-99-Q-0005 as a request for quote (RFQ) for One Packaged Air Cooled Rotary Chiller, Trane Model #RTAA-125 or approved equal with the following minimum features and accessories: 1)Nominal 125 tons cooling. 2)460/3/60 input power. 3)Single 115/1/160, 15 amp connection F evaporator barrel heater tape and control power. 4)Provide a factory mounted and wired control power transformer 5)Dual independent refrigerant circuits. 6)Compressors shall be rotary (screw) type. (reciprocating compressors ARE NOT acceptable. 7)Provide modulated unloading of 15 percent capacity (provide factory install hot gas bypass on both refrigerant circuits if chiller cannot unload to 15 percent). 8)Factory installed low ambient head pressure controls for cooling to 25 degrees fahrenheit. 9)Refrigerant suction and discharge pressure display for each refrigerant circuit. 10)over/under voltage protection, factory mounted and wired. 11)Phase failure/reversal protection, factory mounted and wired. 11)Phase failure/reversal protection, factory mounted and wired. 12)Louvered condenser hail guards with maximum openings of 1 half inch x 6 inch (must completely cover condenser coils and compressor/evaporator access area). Wire screens are not accptable equal. 13)Factory charges with refrigerant and oil. 14)Factory mounted and wired compressor starts counter and run time meter for each compressor. 15)Microprocessor control of leaving water temperature with digital display of entering and leaving water temperatures, operating mode and diagnostic service information. Microprocessor must be capable of accepting either A 0-10 Vdc or 4-20 mA chilled water reset signal. 16)Vaporproof water flow switch provided for field mounting and wiring. 17)Provide the services of the manufactures service company for start-up, checkout and 12 months parts, refrigerant and labor warranty. REQUIRED PERFORMANCE DATA: Minimum Cooling Tons 122.5 EWT 52.8 Degrees Fahrenheit LWT 45.0 Degrees Fahrenheit GPM 375 Maximum WPD 33 Feet Design Ambient 92.0 Degrees Fahrenheit Low Ambient 15.0 Degrees Fahrenheit Minimum Full Load Efficiency 10.2 EER Minimum Part Load Efficiency 12.9 NPLV Modulated Unloading 15 Percent -- 100 Percent Volts/Phase/Hz 460/3/60 MCA 253 AMPS MFS 350 AMPS ALL PERFORMANCE DATA SUBMITTED MUST BE RATED AND CERTIFIED IN ACCORDANCE WITH ARI STANDARD 590-98 This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-18. The provisions at 52.212-1, Instructions to Offerors -- Commercial; 52.212-2, Evaluation -- Commercial Items; 52.212-3, Offeror Representations and Certifications -- Commercial Items; 52.212-4, Contract Terms and Conditions -- Commercial Items; and 252.204-7004, Required Central Contractor Registration apply. Posted 08/09/00 (W-SN484094). (0222)

Loren Data Corp. http://www.ld.com (SYN# 0216 20000811\41-0001.SOL)

41 - Refrigeration, Air Condition and Air Circulating Equipment Index  |  Issue Index |


Created on August 9, 2000 by Loren Data Corp. -- info@ld.com