system is required to record hydrophone data for the Pacific Missile
Range Facility's (PMRF) Barking Sands Underwater Tactical Range and
other expansion ranges. GENERAL REQUIREMENT: The system should include
dual, high data-rate digital recorders, analog/digital and
digital/analog converters, multiplexing and demultiplexing units, a
patch panel interface and software graphic user interface. The
equipment shall dynamically assign recording bandwidth depending on
hydrophone select messages provided by the PMRF UTS Ethernet. At least
50 hydrophones will have to be recorded and played back at any one
time. Mux/Demux Subsystem requirement: shall digitize and multiplex the
hydrophone data into a telemetry stream for recording, shall be capable
of handling at least 50 channels with an analog bandwidth of 40 kHz per
channel or greater, the A/D and D/A converters shall be no less than 10
bits and shall be synchronously latched to preserve the original
channel to channel timing relationship to within 10 microseconds,
header information shall be integrated into the data stream; Tape
Recording Subsystem requirement: shall be capable of recording the
digital data stream corresponding to the maximum data rate generated by
at least 50 channels of hydrophone data; System Electrical
Specifications: shall be able to record and play back a maximum
hydrophone signal level of 1 Volt-RMS as measured in a 40 kHz band, the
dynamic range of the system shall not be less than 60db, Inter-channel
cross-talk and distortion measured during playback shall be less than
60 dbv when recording a 1 VRMS tone at 13 kHz and 37 kHz, all
out-of-band signals shall be a minimum of 50 dB down from the peak
output level, and be compatible with a hydrophone signal source
impedance of just a few ohms, anti-aliasing filters required; External
Interfaces requirement: shall input and output analog hydrophone
signals to the PMRF Tape Recorder Patch Bay. The contractor shall
provide 178 (ea) sixty-foot long "Record" coaxial cables and 178 (ea)
sixty-foot long "Replay" coaxial cables terminated with Trompeter PL50
plugs to mate with a Government furnished tape recorder patch bay.
Detailed specifications will be provided in RFP. Delivery and
installation at Kekaha, HI. Requirement to include onsite operation and
maintenance and software training, and documentation. Anticipate FFP
contract. Completion of project within 180 days ADC. All responsible
sources may submit an offer, which shall be considered. All interested
parties are urged to provide their CAGE code with their written
request for solicitation documents. See Notes 1, 26. Posted 08/15/00
(W-SN486085). (0228) Loren Data Corp. http://www.ld.com (SYN# 0263 20000817\58-0001.SOL)
| 58 - Communication, Detection and Coherent Radiation Equipment Index
|
Issue Index |
Created on August 15, 2000 by Loren Data Corp. --
info@ld.com
|
|
|