Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF AUGUST 23,2000 PSA#2670

Los Alamos National Laboratory, PO Box 1663, Mail Stop: D442, Los Alamos, NM 87545

66 -- ALUMINUM ALLOY HIGH-PRESSURE HELIUM GAS CELL SOL 16332-sol-00 4y DUE 091600 POC Dan Gill @(505)-667-3179 or Elda Childers @(505)-665-3524 E-MAIL: dangill@lanl.gov or childers_elda_d@lanl.gov, dangill@lanl.gov or childers_elda_d@lanl.gov. Item 1 -- Design, fabricate and test Aluminum alloy high-pressure helium gas cell -- External size: 8mm, Diameter size: not-to-exceed 65mm, Length -- no more than 160mm. Maximum Allowed Working Pressure (MAWP) 150,000-175,000psi (10-12 kbar), depending on internal diameter) for Maximum Operating Pressure (MOP) 100,000-150,000psi (7-10 kbar) or better. For use with nonpolar fluids (dry helium gas or hydrocarbon liquids). Material must be aluminum alloy (7075) or better). High-pressure fittings for connection to existing hig-pressure gas system to be determined in consultation with the University Technical Representaive. Item 2 -- same as item 1 except for 10mm internal diameter. Item 3 -- Same as item 1 except for 12mm internal size and length 80mm. Item 4 -- Manganin gauge steel cell -- This cell is intended to be part of the high-pressure gas system and will be used for high precision pressure measurement. It consists of a pressure containment vessel into which a manganin wire pressure gauge is installed. Equipped with four electrical leads into high-pressure volume. MAWP 200,000psi (14 kbar) for MOP of 175,000psi (12 kbar). For use with chemically inert gases and nonpolar fluids. This cell must be provided with a jack of circulation of thermo-stblizing liquid. Internal size: Diameter -- 10mm, Length -- 70mm. High pressure fittings for connection to existing high-pressure gas system to be determined in consultation with the University Technical Representative. Note: Internal diameters are given and external diameter should not exceed 8 inches. Item 5 -- Pressure stabilizeer steel cell. This cell is intended to be part of the the high-pressure gas system. Internal volume 12mm diameter X 100mm length. MAWP 200,000psi (14 kbar) for MOP of 175,000psi (12 kbar) for use with nonpolar fluids (dry helium gas). Equipped with four electrical leads into connection to existing high-pressure gas system to be determined in consultation with the University Technical Representative. Note:Internal diameters are given and external diameter should not exceed 8 inches. If you are interested in submitting a proposal please contact Dan Gill or Elda Childers to receive an RFQ package. Posted 08/21/00 (W-SN488326). (0234)

Loren Data Corp. http://www.ld.com (SYN# 0295 20000823\66-0025.SOL)

66 - Instruments and Laboratory Equipment Index  |  Issue Index |


Created on August 21, 2000 by Loren Data Corp. -- info@ld.com