COMMERCE BUSINESS DAILY ISSUE OF AUGUST 28,2000 PSA#2673 Department of Veteran Affairs Medical Center, Contracting Officer
(9-90C), 3601 S. 6th Avenue, Tucson, AZ 85723 65 -- PERFUSION SYSTEM SOL 678-87-00 DUE 091200 POC Larry Miller,
Contract Specialist Tel: 520-629-4614 Fax 520-629-1817 E-MAIL:
James.Waterman@med.va.gov, Larry.Miller4@med.va.gov. This is a combined
synopsis/solicitation for commercial items prepared in accordance with
the format in Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; proposals are being requested and a written
solicitation will not be issued. This solicitation number 678-87-00 is
issued as a Request for Quotation. The solicitation document and
incorporated provisions and clauses are those in effect through Federal
Acquisition Circular 97-18. This is a 100% Small Business Set-Aside.
The SIC is 3845. The Size Standard is 500 employees. Clauses and
Provision from the Federal Acquisition Regulation (FAR) may be obtained
online at http://www.arnet.gov/far,Veteran's Administration Acquisition
Regulation (VAAR ) are available online at http://www.va.gov
/oa&mm/vaar/ Description: Characteristics for a Perfusion System: Item
001: (2 ea) Base with four microprocessor-controlled peristaltic pump
units, 115v, 13 amps, in spill proof enclosure; Item 002: (8 ea)
Roller Pump, 115v; (2 ea) Safety Monitor with mounting arm; Item 003:
(2 ea) Ultrasonic Air Sensor, 3/8" sensor with tubing (9.5mm) ID x
3/32" (2.4mm) wall; Item 004: (2 ea) Arterial Monitor fully integrated
display for one pressure, three temperatures and two timers.
Temperature monitoring range 0-49.9 degrees C, Pressure monitoring
range 45-990 mmHg with alert and alarm settings, two independent timers
with hours, minutes and seconds up to 9 hours, 59 minutes, 59 seconds;
Item 005: (2 ea) High Intensity Quartz Lamp; Item 006: (2 ea) Cable
Clamp Assembly. Minimum required operating characteristics: Safety
monitor that can be set to stop the designated arterial pump if air is
detected or the reservoir lever is low. Equipment must be
self-diagnostic. Roller pumps must be belt driven; the belt driven
system requires no replacement and is guaranteed for the life of the
unit. The roller mechanism must be field adjustable. Pump modules must
be usable separate from the base. Precise digital readouts that
display flow rates in liters per minute or revolutions per minute. Pump
speed must be measured by an accurate optical tachometer. Must have a
safety system that requires operator to re-start any pump that stops
due to an alarm situation. Must have a pulse width modulator motor
control to regulate incoming power values precisely. Equipment shall be
fully warranted for a period of 12 months including all repairs, parts
and labor. Delivery shall be made between 8:00 AM and 4:00 PM, Mon-Fri
to the Southern Arizona VA Health Care System (SAVAHCS), Warehouse
Bldg. 14, 3601 South Sixth Avenue, Tucson, AZ 85723 not later than 60
days after award. Supplier/Manufacturer shall provide authorized
service representatives to install, set-up and test. Include as a
separate line Item 006: the cost for training two biomedical engineers
employed by the SAVAHCS. Training shall include all required service
and maintenance manuals. Toll Free Technical Support must be available.
Product or descriptive literature may be submitted along with the
offer. If used this literature must clearly indicate that the equipment
meets the characteristics and minimum operational requirements
specified.The provisions at 52.212-1, Instructions to Offerors
Commercial, applies to this acquisition. Offerors are to include a
completed copy of the provisions at 52.212-2, Offeror Representations
and Certifications Commercial Items, and VARR 852.219-70 Veteran-Owned
Small Business with its offer.The provisions at 52.212-2 Evaluation
Commercial Items are applicable to this solicitation. The evaluation
criteria included in paragraph (a): The following factors shall be used
to evaluate offers: (i) the technical capability of the item offered to
meet the Government Requirement and (ii) Price. Where technical
capability is greater than price.The clause at 52.212-4, Contract Terms
and Conditions Commercial Items, applies to this acquisition and
addenda: FAR 52.203-3 Gratuities, FAR 52.232-34 Payment by Electronic
Fund Transfer, FAR 52.247-34 F.O.B. Destination and VAAR 852.211-71
Guarantee Clause, VAAR 852.211-72 Inspection, VAAR 852.233-70 Protest
Content, VAAR 852.237-70 Contractor Responsibilities, VAAR
Representatives of Contracting Officer, VAAR 852.211-70 Requirements
for Operating and Maintenance Manuals, VAAR 852.270-4 Commercial
Advertising. The clause at 52.212-5, Contract Terms and Condition
Required To Implement Statutes or Executive Orders Commercial Items,
applies to this acquisition. The following clauses cited are applicable
to this Acquisition: 1, 5, 7, 11, 12, 13, 14, 15, 17 and 24. Contact
information regarding this solicitation: Larry Miller 520-629-4614.
Offers are due on or before 2:00 PM, September 12, 2000 at Southern
Arizona VA Health Care System (9-90C), 3601 South Sixth Ave., Tucson,
AZ 85723. Posted 08/24/00 (W-SN489947). (0237) Loren Data Corp. http://www.ld.com (SYN# 0331 20000828\65-0005.SOL)