Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 19, 2000 PSA #2750
SOLICITATIONS

99 -- FUEL STORAGE TANKS -- EXTREME DUTY

Notice Date
December 15, 2000
Contracting Office
Bureau of Land Management, 6881 Abbott Loop Rd., Anchorage, AK 99507
ZIP Code
99507
Solicitation Number
LAQ012001
Response Due
January 12, 2001
Point of Contact
Terese Bertini (907) 267-1320 FAX (907) 267-1434
E-Mail Address
mbertini@ak.blm.gov (mbertini@ak.blm.gov)
Description
This is a combined synopsis/solicitation for Commercial Items prepared in accordance with the format in Subpart 12.6 as supplemented with additional information included in this notice. The announcement constitutes the only solicitation: offers are being requested and a written solicitation will not be issued. The solicitation number is LAQ012001 this is a request for quote. Applicable FAR solicitation provisions and contract clauses, up through Federal Acquisition Circular (FAC)97-20, are hereby incorporated by reference into this RFQ. The Contracting Officer has found and determined that this proposed procurement is appropriate for an "unrestricted" procurement pursuant to FAR subpart 19.502 (Setting Aside Acquisitions). All responsible sources may submit a price quotation which will be considered. The Bureau of Land Management, Alaska Fire Service has a requirement for 500 gallon and 2500 gallon fuel storage tanks -- extreme duty. The solicitation line-items are as follows: 2500 GALLON COLLAPSIBLE AVIATION FUEL STORAGE TANKS -- EXTREME DUTY Quantity 8 each A. Tanks must be suitable for the storage of Jet "A" -- Jet "B" -JP"4" and avgas with excellent resistance to high aromatics, abrasions and tears. B. Tank dimensions will not exceed 228 inches long by 102 inches wide when empty or exceed a dry weight of 160 pounds. C. Each tank will have two-inch standard N.P.T. female fitting for both fill/discharge and vent. One reducer from the three- inch to two inch will be allowed on fill/discharge port. No galvanized or poly type fitting will be used. Only anodized aluminum will be used. D. Each tank will be supplied with an aluminum two-inch vent, spark arrester and pressure relief. An aluminum two-inch camloc female fitting will be attached to one end of vent tube. E. Handles are required on both ends and both sides and will be appropriately spaced and reinforced to allow suspension of the tanks from one end or one side for inspections, repairs, and cleaning purposes with no folds or wrinkles. F. Each tank will be stenciled with one-inch lettering: Maximum Bill Height, Empty Weight, Date of Manufacture, Serial Number, and Capacity. G. Each tank will be stenciled in four-inch lettering on two sides: No Smoking Flammable Liquid, in red. No smoking to be placed above flammable liquid. H. A repair kit with instructions for minor field repairs will be included with each tank. I. Each tank will be supplied with its own heavy duty, anti-abrasion, puncture resistant shipping cover complete with straps, buckles, and handles suitable for field use. No zippers will be used. J. Each bidder will submit a four inch by six inch sample of tank material to be used, claims to resistance of aromatic fuels, U.V. light abrasions and tears, life expectation under normal field conditions, and if major repairs are offered at their facility when submitting their bid.. K. F.O.B. will be Bureau of land Management, Alaska Fire Service Fr. Wainwright, Alaska 99703 500 GALLON COLLAPSIBLE AVIATION FUEL STORAGE TANKS -- EXTREME DUTY 12 EACH A. Tanks must be suitable for the storage of Jet "A" -- Jet B" -- JP"4" and avgas, with excellent resistance to high aromatics, and tears. B. Tank dimensions will not exceed 116 inches by 68 inches wide when empty or exceed a dry weight of 60 pounds. C. Each tank will have a two-inch standard N.P.T. female fitting for both fill/discharge and vent. One reducer from three inch to two inch will be allowed on fill/discharge port. No galvanized or poly type fitting will be used. Only anodized aluminum will be used. D. Each tank will be supplied with an aluminum two-inch vent, spark arrester and pressure relief. An aluminum two-inch camloc female fitting will be attached to one end of vent tube. E. Handles are required on both ends and both sides and will be appropriately spaced and reinforced to allow suspension of the tank from one end or one side for inspections, repairs, and cleaning purposes with no folds or wrinkles. F. Each tank will be stenciled with one inch lettering: Maximum Fill Height, Empty Weight, Date of Manufacture, Serial Number, and Capacity.. G. Each tank will have stenciled in four-inch lettering on two sides: No Smoking Flammable Liquid, in red. No Smoking to be placed above the Flammable Liquid. H. A repair kit with instructions for minor field repairs will be included with each tank. I. Each tank will be supplied with its own heavy duty, anti-abrasion, puncture resistant shipping cover complete with straps, buckles, and handles suitable for field use. No zippers will be used. J. Each bidder will submit a four inch by six inch sample of tank material to be used, claims to resistance or aromatic fuels, U.V., light abrasions and tears, life expectation under normal field conditions, and if major repairs are offered at their facility when submitting their bid. K. F.O.B. will be BLM Alaska Fire Service, Ft. Wainwright, Alaska 99703 Any technical questions should be directed to Lindsay Wyatt, ((07) 356-5664 or 5575. FAX (907) 356-5719 Evaluation will be made on type of material, manufactured style, past performance and price. The provisions at FAR 52.212-1, Instructions to Offeror's-Commercial Items, and FAR 52.212-3, Offeror Representations and Certifications-Commercial Contract Terms and Conditions-Commercial Items, is applicable- must be completed and provided with offer: 52.212-4 Contract terms and Conditions- Commercial Items; 52.212-5 Contract Terms and conditions Required to Implement Statues or Executive Orders-Commercial Items, which includes 52.203-6, Restriction on Subcontractor Sales to the Government with Alternate I and 52.232-34, Payment of Electronic Funds Transfer Non-Central Contractor Registration; 52.204-6 Contractor Identification Number Data Universal Numbering System (DUNS). The closing date for this request for quote will be January 12,2001. The required delivery date for these items is March 30, 2001.
Record
Loren Data Corp. 20001219/99SOL007.HTM (W-350 SN509024)

99 - Miscellaneous Index  |  Issue Index |
Created on December 15, 2000 by Loren Data Corp. -- info@ld.com