Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF APRIL 19, 2001 PSA #2833
SOLICITATIONS

46 -- AUTOMATIC TABLET CHLORINATOR SYSTEMS

Notice Date
April 17, 2001
Contracting Office
Department of the Air Force, Air Combat Command, 99 CONS, 5865 Swaab Blvd, Nellis AFB, NV, 89191-7063
ZIP Code
89191-7063
Solicitation Number
F26600-01-Q-A038
Response Due
April 27, 2001
Point of Contact
Lori Washington, Contracting Apprentice, Phone 702-652-5352, Fax 702-652-2532, Email lori.washington@nellis.af.mil -- Michael Bumpus, Contract Specialist, Phone 702-652-5321, Fax 702-652-5405, Email
E-Mail Address
Lori Washington (lori.washington@nellis.af.mil)
Description
The 99th Contracting Squadron at Nellis AFB NV intends to award a purchase order under Simplified Acquisition Procedures for the purchase of two Hammonds or equal, Automatic Tablet Chlorinator Systems. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6 and 13.5, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Proposals are being requested and a written solicitation will not be issued. This solicitation (F26600-01-Q-A038) is issued as a Request for Quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-24 and the Defense Acquisition Circular 91-13. This solicitation is 100% SETASIDE FOR SMALL BUSINESS CONCERNS in accordance with FAR Part 19. The North American Industry Classification System (NAICS) code is 333911, size standard 500. The contractor shall provide the following: Transportation, delivery to destination, tools, instructions (to include manuals) for CLIN 0001: ISSICAMFPCO8PEH75HP220SVAC chlorinator system, QTY 1 ea. Operating Conditions: Application: CRC Water; Main System Flow Rate: Variable 300 GPM-1000 GPM; Desired Chlorine Residual: 0.2-2.0 LBS/HR; Chlorinator System Inlet Pressure: 30-70 PSI (Inlet PRV required); Chlorinator System Outlet Pressure: 80-PSI Maximum; Electric Voltage available: 220V AC, single phase (electrician verified). CLIN 0002: ISSICAFPC12FX75LP220SVAC chlorinator system, QTY 1 ea. Operating Conditions: Application: Wells; Main System Flow Rate: #11@332 GPM, #12@540 GPM, #13@540 GPM, #14@449 GPM Total combined =1762 GPM; Desired Chlorine Residual: 1.0 PPM; Demand PPM 0.5; Chlorine Required: #11@0.25, #12@0.34, #13@0.41, #14@0.33 Combined @ 1.33 LBS/HR; Chlorinator System Inlet Pressure: 40 PSI (Inlet PRV required); Chlorinator System Outlet Pressure: 5.62-13.85 PSI; Electric Voltage Available: 220V AC Single Phase (electrician verified). Offerors must provide brochures/literature and specification of the items being offered along with their quote. The technical literature submitted needs to clearly communicate the offeror understanding and compliance with the minimum requirements as set forth in the specifications or any alternative proposal submitted in response to this RFQ. Discussions may or may not be held with offeror; therefore, each offeror proposal should be complete and accurate. The Government requires FOB destination. FOB point is Nellis Air Force Base, Nevada 89191. The required delivery date is 29 May 2001. Offers are due by 2:30 p.m. (PST) on 27 Apr 01, and can be mailed or hand carried to 99 CONS/LGCA, Attn: TSgt Lori Washington, 5865 Swaab Blvd. Nellis AFB, NV 89191-7063, or sent by facsimile to (702) 652-9570. The following provisions and clauses can be viewed through Internet access at the Air Force FAR Site, http://farsite.hill.af.mil. In accordance with FAR 52.252-1, Solicitation Provisions Incorporated by Reference and FAR 52.252-2, Clauses Incorporated in Reference, the following provisions and clauses are incorporated by reference: FAR 52.212-1, Instruction of Offerors-Commercial Items, with the following technical description of the items being offered in sufficient detail to evaluate compliance with the requirement of the solicitation (i.e. product literature), the terms of any expressed warranty, price and any discounts, and delivery times; FAR 52.212-2, Evaluation of Commercial Items, award will be made to the offeror whose proposal represents the best value to the Government. Evaluation factors are price and price related factors, delivery time, and represents the best value to the Government. OFFERORS MUST INCLUDE WITH THEIR PROPOSALS A COMPLETED COPY OF THE PROVISION AT 52.212-3, OFFEROR REPRESENTATIONS AND CERTIFICATIONS-COMMERCIAL ITEMS. Failure to provide any of the aforementioned items will deem offeror ineligible for award. FAR 52.212-4 Contract Terms and Conditions-Commercial items applies to this solicitation. FAR 52.212-5, Contract Terms and Conditions Required to Implement Statues or Executive Orders-Commercial items, applies to this solicitation. The following clauses also apply to this solicitation: FAR 52.202-1, Definitions; FAR 52.203-3, Gratuities; FAR 52.203-5, Covenant Against Contingent Fees, FAR 52.203-7, Anti-Kickback Procedures; FAR 52.204-4, Printing/Copying Double Sided on Recycled Paper; FAR 52.222-21, Prohibition of Segregated Facilities; FAR 52.222-26, Equal Opportunity; FAR 52.222-35, Affirmative Action for Disabled Veterans and Veterans of the Vietnam Era; FAR 52.222-36, Affirmative Action for Workers with Disabilities; FAR 52.222-37, Employment Reports on Disabled Veterans and Veterans of the Vietnam Era; DFARS 252.225-7036 Buy American Act -- -Trade Agreements -- -Balance of Payment program; FAR 52.243-1, Changes; FAR 52.232-33 Payment by Electronic Funds Transfer; DFAR 252.204-7004, Required Central Contract Registration. For solicitations after 1 Jun 98 all contractors are required to register in the Central Contractor Registration (CCR) for award. If not already registered, you should immediately register with CCR by calling 1-888-227-2423 or via the Internet at http://ccr2000.com. Contact Contracting Specialist, TSgt Lori Washington (lori.washington@nellis.af.mil) at (702) 652-5352 or Contracting Officer, Mr. George D. Dowdey (george.dowdey@nellis.af.mil) at (702) 652-2099, for information regarding this combined synopsis/solicitation.
Web Link
Visit this URL for the latest information about this (http://www.eps.gov/cgi-bin/WebObjects/EPS.woa/wa/SPF?A=R&P=F26600-01-Q-A038&L=885)
Record
Loren Data Corp. 20010419/46SOL002.HTM (D-107 SN50J4Z7)

46 - Water Purification and Sewage Treatment Equipment Index  |  Issue Index |
Created on April 17, 2001 by Loren Data Corp. -- info@ld.com