COMMERCE BUSINESS DAILY ISSUE OF JUNE 6, 2001 PSA #2866
SOLICITATIONS
49 -- PROVIDE/INSTALL TORIT ENVIRONMENTAL CONTROL BOOTH, ECB-6
- Notice Date
- June 4, 2001
- Contracting Office
- Department of the Air Force, Air Combat Command, 99 CONS, 5865 = Swaab Blvd, Nellis AFB, NV, 89191-7063
- ZIP Code
- 89191-7063
- Solicitation Number
- F26600-01-Q-B065
- Response Due
- June 24, 2001
- Point of Contact
- Jeff Bishop, Contract Specialist, Phone 702-652-9573, Fax = 702-652-5405, Email jeffrey.bishop@nellis.af.mil -- John O'Dell, = Contract Specialist, Phone 7026529577, Fax 7026525405, Email = john.odell@nellis.af.mil
- Description
- Provide and install Torit Environmental Control Booth, Model = ECB-6. Equivalents will not be considered. Booth specifications are: = 220 inch x 90 inch Work Space; 3,960 sq ft Filter Area; 6.8:1 = Air-to-media ratio; six (6) Fibra-web Filter Cartridge Material; 36 = Filters; 4,500 cfm per power module, face velocity Design Flow;160 fpm; = Composite Grinding Application; 5hp, 3450 rpm, 640 volt/3 phase/ 60 Hz = TFEC and aluminum airfoil fan wheel Motor; fan mounted on the clean = side of the filters to avoid contact with dust laden air. Contractor = shall provide all labor, materials, supplies, equipment, = transportation, and all else necessary to install the booth to a = complete and usable facility. Thirty-six (36) additional replacement = filter cartridges shall be provided. Work includes, but is not limited = to installation of electrical wiring and compressed air piping from = government's supply (not to exceed 50 lineal feet from booth). This is = a 100% set-aside for small business participation. The applicable = NAICS for this acquisition is 334512 with a three year average annual = small business size standard of 500 employees. The solicitation will = be electronically issued on the Government?s EPS (Electronic Posting = System, http://www.eps.gov) or, if the site is unavailable, a copy may = be e-mailed to the requestor's address. PAPER COPIES WILL NOT BE = AVAILABLE. NOTE: Any prospective contractor must be registered in the = Central Contract Registration (CCR) in order to be eligible for award. = Registration requires applicants to have a DUNS number. Registering = may take up to 3 weeks to process. Contractors may access the CCR at = http://ccr.edi.disa.mil. Recommend registering immediately in order to = be eligible for timely award. =20
- Web Link
- Visit this URL for the latest information about this (http://www.eps.gov/spg/USAF/ACC/99CONS/F26600-01-Q-B065/listing.htm= l)
- Record
- Loren Data Corp. 20010606/49SOL001.HTM (D-155 SN50N8I1)
| 49 - Maintenance Repair Shop Equipment Index
|
Issue Index |
Created on June 4, 2001 by Loren Data Corp. --
info@ld.com
|
|
|
|