Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF JUNE 15, 2001 PSA #2873
SOLICITATIONS

66 -- SIGNAL GENERATORS

Notice Date
June 13, 2001
Contracting Office
WR-ALC/PKOC, 235 Byron St, Robins Air Force Base GA 31098-1611
ZIP Code
31098-1611
Solicitation Number
FE206710190126
Response Due
June 27, 2001
Point of Contact
A1C Jason A. Porter WK:(478) 926-5151 Fax: (478) 926-3569
E-Mail Address
Click here to contact A1C Porter via e-mail for any (jason.porter@robins.af.mil)
Description
2 each Signal Generators The following Requirements are necessary specifications for the AN/ARN-147 Testing. RF Outputs Frequencies VOR/LOC 108.00to117.95 MHZ in 50-Khz Steps Glideslope 329.15 to 335.00 Mhz selectable in150 Khz steps Marker Beacon 74.6 to 75.4 Mhz selectable in 25 Khz steps Frequency Vernier Varies selected output frequency>+ or -- .03% Frequency resolution Fixed,1 Khz: vernier 100Hz Frequency accuracy <+ -- 2ppm,(+10 to +40 deg. Celcius(+50 to +104 deg. Fht.) including aging. Output level range Db mw 6 to 120db mw variable in 1 db increments Voltage 112 mV to .22 micro V,variable in 1 db increments Accuracy -6 to 60 db mW +- 1.5 Db -6- to 120 db mW +- 2.0 db Vswr <1.5:1 Spectral purity Harmonics VOR/LOC or marker beacon >30 DB below carrier Glideslope >25 DB below carrier Spuious signals >80 DB below carrier Broadband Noise(ssb) 74.60 to 75.40 MHZ (marker beacon) > 115 dbc/hz > 40 Khz from carrier 108.00 to 117.95 Mhz (VOR/LOC) >122 dbc/hz >40 khz from carrier 329.15 to 335.00 Mhz (glideslope) > 115 dbc/hz >120 khz from carrier VOR mode Modulation tones Frequencies 30-hz reference,30-hz variable,9960 hz and 1020 hz ident Frequency Accuracy +- .005% Distortion (audio) 30-hz reference <.25% 9960 hz and 1020 hz <.50 % 9960-hz fm deviation 480 hz +- 2hz peak Radial range 000.00 to 359.99 degrees (selectable in .01 degrees increments,variable in preset steps of +30 degrees +-10 degrees, and +- .01 degree.) Radial accuracy +- 0.01 degree of selected radial Amplitide modulation Range (per Tone) Preset(1020 hz ,30-hz variable,9960hz) 30 .0% Variable 10.0 to 35.0 percent in .1 percent increments Accuracy +- 2.5% of indicated modulation for preset mode. Tone distortion (at 30% modulation) 30-hz variable <1.0 percent 9960 hz <1.5% 1020hz <1.0 % Total VOR demodulated error <+-0.05 degree of selected radial ILS Mode Modulation tones Frequency Localizer 90,150,and 1020 hz Gliseslope 90 and 150 hz Frequency accuracy +-.005% Distortion (audio) 90 and 150 Hz <.25 % 1020 Hz <.50 % 90- and 150-hz Fixed 0.0 degree Selectable 60 degrees Amplitude Modulation Range (per tone) Localizer Preset 20% Variable 5.0 to 40.0 % in.1-percent increments Glideslope Preset 40% Variable (at beam center only) 10.0 to 80.0 % in .1-percent increments 1020 hz(localizer only) 30 % ,fixed Accuracy +-2.5 % of indicated modulation for preset mode. Tone Distortion(rf) Localizer,90 and 150 hz < 1% (20-% modulation Glideslope ,90 and 150 hz <1 %(40-% modulation 1020 hz (localizer only) < 1%(30-% modulation DDM Localizer Preset 0.000 Selectable settings 0.000+-.046,+-.093,+-.155,+-.400 Variable Range +-.400,in .001 increments GLIDESLOPE Preset 0.000 Selectable Settings 0.000,+-.045,+-.091,+-.175,+-.400 Variable range +-.800,in .001 increments Audio error On course .0001 DDM Off Course .0002DDM Modulator Error On Course .00046 DDM Off Course .000046DDM +2.5%DDM Glideslope On Course .00092 DDM Off Course .00092 DDM+2.5% DDM Total System error (Audio +modulation) Localizer On Course .00056DDM Off Course .00056 DDM+2.5%DDM Glideslope On Course .00102DDM Off Course .00102DDM +2.5%DDM Marker Beacon Modulation Tones Frequencies Outer Marker 400 hz Middle marker 1300 hz Inner marker 3000 hz Frequency accuracy +-.005% Distortion (audio) < 1% Amplitude Modulation Range Preset 95% Variable 90.0 to 97.0 % ,in .1-% increments. Accuracy +-5% Tone Distortion <4% This is a combined synopsis/solicitation for commercial items prepared IAW the formatin FR 12.6 as supplemented with additional information included in this notice. this announcement constitutes the only solicitation; proposals are being requested and a separate written solicitation will not be issued. The following clauses are applicable to subject solicitation: FAR 52.212-1(Instruction to offerors); 52.212-2(Evaluation-commercial items); 52.212-3(Offeror Representations and Certifications-Commercial Items); 52.212-4(Cotract Terms and Conditions-Commercial Items); 52.212-5(Contract Terms and Conditions Required to Implement Statues of Executive Orders-Commercial Items). In accordance with clause 52.212-2, the evaluation factors shall be based on: price and price related factors. Quotations should be faxed to 478-926-3569 or e-mail to jason.porter@robins.af.mil. The anticipated award date is 27 June 2001.Note: All offerors must be registered in the Central Contracting Registration program(CCR)_prior to consideration for award of any DOD contract/purchase order.
Record
Loren Data Corp. 20010615/66SOL008.HTM (W-164 SN50O8E0)

66 - Instruments and Laboratory Equipment Index  |  Issue Index |
Created on June 14, 2001 by Loren Data Corp. -- info@ld.com