COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 4, 2001 PSA #2928
SOLICITATIONS
J -- UPGRADE EXISTING OVERHEAD PAGING SYSTEM
- Notice Date
- August 30, 2001
- Contracting Office
- Department of Veterans Affairs, Great Lakes Healthcare Systems, Great Lakes Acquisition Center, Bldg. 5, 5000 West National Ave., Milwaukee, WI 53295
- ZIP Code
- 53295
- Solicitation Number
- 69D-224-01
- Response Due
- September 6, 2001
- Point of Contact
- Diane Brazale, Contracting Officer, (414) 902-5403
- Description
- The following Amendment No. 2 is issued to Solicitation No. 69D-224-01, CBD Submission No. 50V295 dated 8/16/01. The purpose of this Amendment is to provide additional information on existing speaker locations and zone definitions. In addition, this amendment includes information on the main components of the existing equipment. As per specifications, contractor shall be required to utilize the existing equipment to the fullest extent possible. A. Zone Definition. All floors are incremented by 1 floor. Zone Approx. Bldg. Floors Description # of Speakers 1 60 1 1 Admitting, Emergency Room 2 150 1 1 Front lobby, north and west corridors 1 2,4 Entire 2 floors 1 3 Entire floor except 3-South wing 3 120 1 3 3-South wing 1 5-10 Entire 6 floors 4 70 11B 2-7 Entire 6 floors 5 120 11A 1, 3, 5, 7 Entire 4 floors 30 1 Entire floor, except Outpatient Pharmacy SPECIAL NOTE: THIS IS HIGH NOISE AREA 6 60 11A 2,4,6 Entire 3 floors 7 20 11B 1 Entire floor 8 15 30 1 Outpatient Pharmacy HIGH NOISE AREA Total speakers: 615 (approximately) B. Existing Equipment Specifications: 1. Main console/equipment racks: Equipment is primarily Bogen, with some Rauland, Shure, and Biamp, Most of the Bogen equipment is well over 10 years old; other equipment is approximately 4 years old. 2. Speakers, typical, ceiling-mounted Rauland USO (188) 8-inch, dual-cone speaker Permanent magnet, seamless cone type with an additional cone to extend high frequency response. 8 watts RMS power output Transformer: 25V/70V; taps: 5/16, 5/8, 1 , 2 , 5 watts Frequency range: 65-17,000 Hz 3. Rauland ACC1101 back box, recessed (also some Soundolier SE175-4 surface-mount back boxes for wall-mounted speakers) 4. Rauland ACC1001 flush-mount ceiling baffle (also some Soundolier 161-8 surface-mount baffles for wall-mounted speakers) 5. Rauland ACC 1104 T-bar Support Bridge 6. Belden (8461) 18 gage, PVC insulated, twisted pair cable. There are no other changes to the specifications. No change in Offer Due Date. Electronic copy of this Amendment may be obtained FREE at the following URL: http://www.va.gov/oa&mm/busopp/sols.htm, Amendment No. 2.
- Record
- Loren Data Corp. 20010904/JSOL018.HTM (W-242 SN50W576)
| J - Maintenance, Repair and Rebuilding of Equipment Index
|
Issue Index |
Created on August 30, 2001 by Loren Data Corp. --
info@ld.com
|
|
|
|