Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 19, 2001 PSA #2980
SOLICITATIONS

58 -- MARKET SURVEY FOR ADDITIONAL SOURCES FOR HIGH POWER AMPLIFIER AM-7498/G

Notice Date
November 15, 2001
Contracting Office
US Army, CECOM, Communications Directorate, Fort Monmouth, NJ 07703-5000
ZIP Code
07703-5000
Solicitation Number
N/A
Response Due
December 14, 2001
Point of Contact
Michael McIntyre, Production Engineering Specialist -- TAMSCO Contr Spt, (732) 532-5083
E-Mail Address
CECOM POC (Michael.McIntyre@mail1.monmouth.army.mil)
Description
This is a Market Survey to identify additional manufacturers/vendors to qualify as Approved Sources of Supply for High Power Amplifier (HPA) AM-7498/G and all of its subassemblies (except the 2.5kW TWT) via a five (5) year Indefinite Delivery, Indefinite Quantity (IDIQ) Flexible Long Term Contract (FLTC). The HPA is used on the military's SATCOM Terminals AN/FSC-78B/C (Heavy), AN/GSC-39B/C (Medium) and AN/GSC-52A (SAMT). Currently, the only Approved Source of Supply for the HPA and its subassemblies is MCL, Inc., Bolingbrook, IL (CAGE Code 16469). The assemblies being considered for procurement and their anticipated Annual quantities are: (Item Name /// NSN /// CECOM Part Number /// MCL Part Number /// Annual Quantity;) HPA AM-7498/G * /// 5895-01-380-8262 /// A3187818-001 /// 30030 /// 16; TWTA AM-7499/G * /// 5895-01-380-8266 /// A3187818-101 /// 15417 /// 10; HVPS PP-8380/G /// 6130-01-381-0959 /// A3187818-102 /// 15418 /// 18; C/S Cable Assy /// 5995-01-426-3235 /// A3187818-104 /// 03C3425-120 /// 7; Prime Pwr Module /// 6130-01-407-6163 /// A3187818-301 /// 13164-208 /// 10; FET Bridge Assy /// 5996-01-420-1296 /// A3187818-302 /// 13165 /// 60; HV Tank Assy /// 6110-01-417-8473 /// A3187818-303 /// 13163 /// 78; Logic Pwr Supply /// 6130-01-431-3273 /// A3187818-304 /// C15418-040 /// 20; HVPS Blower Assy /// 4140-01-412-6658 /// A3187818-305 /// C15418-050 /// 10; Control Display Assy /// 5895-01-414-0676 /// A3187818-306 /// 20100 /// 5; CDA Base CDA /// 5998-01-425-5603 /// A3187818-308 /// D16738 /// 7; CDA Main CCA /// 5998-01-432-5064 /// A3187818-309 /// D16739 /// 35; CDA Local Intrfc CCA /// 5998-01-426-3240 /// A3187818-310 /// D16740 /// 11; Ctrl & Reg CCA /// 5998-01-426-3239 /// A3187818-313 /// D16743 /// 15; IPA Assy /// 5998-01-417-8468 /// A3187818-402 /// C15417-020 /// 6; Anode Switch Assy /// 5895-01-417-8469 /// A3187818-403 /// C15417-055 /// 33; TWTA Blower Assy /// 5895-01-414-4138 /// A3187818-404 /// C15417-030 /// 18; Output Waveguide Assy /// 5895-01-424-6808 /// A3187818-406 /// 27D2967 //// 18; Arc Detector CCA /// 5998-01-414-4135 /// A3187818-407 /// C16731 /// 10; RF SSA /// 5996-01-428-9075 /// A3187818-411 /// 27C3053 /// 16; * The 2.5kW TWTs for these assemblies will be furnished by the government. Interested manufacturers/vendors should understand that any of these items they supply must be form, fit and functional equivalents of and be completely interchangeable with items supplied by MCL, Inc. Manufacturers/vendors not currently qualified as Approved Sources of Supply will also be required to qualify their product(s) via the First Article Test (FAT) requirements stipulated in CECOM Source Control Drawing A3187818 upon contract award. The above items are described in Source Control Drawing A3187818, however, detailed functional and interface requirements for the subassemblies are proprietary to MCL, Inc., and are, therefore, not available. Suppliers interested in providing any or all of the above items must so indicate by writing to Commander, US Army Communications-Electronics Command, Attn: AMSEL-LC-COM-S-TB (Weisbrod/McIntyre), Bldg 1202E Avenue of Memories, Fort Monmouth, NJ 07703. The response must include documentation such as test results, copies of purchase orders if the manufacturer/vendor previously produced any of the items for MCL, Inc., or a statement from MCL, Inc., certifying that the manufacturer/vendor can, in fact, produce items which will be physically and functionally interchangeable with items from MCL, Inc. Prospective manufacturers/vendors may be required to warrant that items they supply will perform satisfactorily when used in their intended application by the military. For additional information, contact Michael McIntyre, preferably via email, at Michael.McIntyre@mail1.monmouth.army.mil or phone (732) 532-5083. Responses must be received no later than December 14, 2001.
Record
Loren Data Corp. 20011119/58SOL013.HTM (D-319 SN5130R2)

58 - Communication, Detection and Coherent Radiation Equipment Index  |  Issue Index |
Created on November 11, 2001 by Loren Data Corp. -- info@ld.com