SOLICITATION NOTICE
Y -- Replace Fences and Gates at Biblis Transmitting Station
- Notice Date
- 1/13/2011
- Notice Type
- Presolicitation
- NAICS
- 515112
— Radio Stations
- Contracting Office
- Broadcasting Board of Governors, Director, Office of Contracts, Germany Transmitting Station, AmConGen - IBB, Unit 24520, APO, 09053-4520
- ZIP Code
- 09053-4520
- Solicitation Number
- IBB-GER-SOL-11-02
- Archive Date
- 2/12/2011
- Point of Contact
- Nim Dedner, Phone: +49-6206-159301, Ludwig HORLEBEIN, Phone: +49-6206159381
- E-Mail Address
-
ndedner@ger.ibb.gov, lhorelbein@ger.ibb.gov
(ndedner@ger.ibb.gov, lhorelbein@ger.ibb.gov)
- Small Business Set-Aside
- N/A
- Description
- General Specifications (Security fence and gates replacement work at Biblis) J.1 (a) Scope The purpose of this work is to replace the existing defective 1.5m high fence with a 2.5m high fence. This installation based on security inspection of IBB Senior Security Officer Michael Lawrence. The present fence and gates are too low, the fence defective, have to be replaced to meet the security standard around the building area. Construction site is approx. 50cm outside of the existing fence line at the outer perimeter fence around the Transmitting station buildings at the Biblis Transmitting Station, Ausserhalb 10, Germany. All work is to be conducted at the site. 2) General Requirements i) The contractor is to supply all labor, machines, tools, construction material and equipment necessary to perform the required work. (2) All installation work is to conform to good professional industry standards for the installation of professional security fence and gate systems. (3) All installation work is to conform to appropriate European and German DIN/VDE, BG and CE standards. The Contractor is to ensure that all work is to be performed in accordance to U. S. and local safety standards. (4) Contractor has to deliver and install all needed material to replace the existing outer perimeter fence and four gates approximately 50cm distance, outside of existing perimeter fence. The contractor has to deliver and install approx 675m new chain link fence, height 2.5m, plus Y-rigger (60mm with 6 lines hot dip galvanized barbed wire dual strand barbs max. distance 10cm), mesh size of chain link 40mm x 40mm, wire thickness minimum 3.8mm, green powder coated RAL 6005, max. pole distance 2.5m, color green, include earthwork and concrete foundations. Contractor is to deliver and install two manual swing gates and two electrical sliding gates clear width 6000mm, height 2.5m powder coated RAL 6005 (moosgrün), with motor drive within all safety related devices needed for personnel and vehicle safety gates; reinforced concrete foundations in accordance with structural requirements for those gates include required ground work and restoring of landscape. Breakdown, remove and dispose/ recycle the existing outer perimeter fence, gates, posts and concrete foundations include required earthwork and restoring of landscape. Finally the contractor is to deliver as built drawings and technical documentation of the new complete fence and gates installation. (5) Construction work is to begin as expeditiously as possible and is to be completed within 2 Month. Working hours are from 07:30 to 15:30 hours (5 days/week); however, the field is to be cleared by 15:30 hours. The broadcasts schedule is subject to change; the site supervisor will advise of any schedule changes that will impact the contractor's work schedule. On German national and American Holidays the Station will be closed. Additional working time is at the discretion of the site supervisor. (6) Contractor is to clean work areas and remove all excess and waste materials from site at completion of work. (7) Utilities including water, electrical, and sanitation are available at site. If utilities are need in work area, the Contractor shall be responsible at his own expense for temporary connections and subsequent removal and restoration thereof after contract work is completed. Contractor must request and coordinate utility connections with site supervisor. (8) Contractor must observe all site security regulations and ensure that no prohibited materials are brought to site. (9) The Contractor is hereby informed that the work site is an active broadcasting radio transmitter system and has therefore electrical hazards. The Contractor shall keep clear of all antenna and transmitter components and shall on no occasion enter within restricted areas (10) Work may be inspected during various stages of progress to ensure compliance with the intended requirements. Station Manager will provide contract management and will supply names of persons authorized to provide direction on his behalf and to answer questions with regard to this work or site regulations. (11) Contractor shall make immediate changes to work completed or under progress should the work not conform the requirements and if changes not agreed to by Station Manager or designated representative. The Contractor should make these changes as expeditiously as possible within the completion period of the Purchase Order. (12) Contractor must provide a competent supervisor at the work site for all periods when maintenance work is in progress. (13) Contractor must show adequate proof of liability insurance to cover any damage to station facility or grounds and must keep insurance in effect during construction period. (14) Warranty period of all work after acceptance shall be two years.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/BBG/ADM/GERMANY/IBB-GER-SOL-11-02/listing.html)
- Place of Performance
- Address: Biblis Transmitting Station, Ausserhalb 10, 68647 Biblis, Germany, Biblis, Germany