Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 25, 2025 SAM #8642
SOURCES SOUGHT

66 -- Gas Chromatograph with Dual Electron Capture Detector (GS-Dual ECD)

Notice Date
7/23/2025 1:01:27 AM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
W40M MRCO EUROPE APO AE 09180-0402 USA
 
ZIP Code
09180-0402
 
Solicitation Number
PANHCA-25-P-0000-025637
 
Response Due
7/29/2025 3:00:00 AM
 
Archive Date
08/13/2025
 
Point of Contact
Bouaphet Phanvongsa, Phone: 3145907916, Michael Hughes
 
E-Mail Address
bouaphet.phanvongsa2.civ@health.mil, michael.w.hughes92.civ@health.mil
(bouaphet.phanvongsa2.civ@health.mil, michael.w.hughes92.civ@health.mil)
 
Small Business Set-Aside
NONE No Set aside used
 
Description
THIS IS A SOURCES SOUGHT/REQUEST FOR INFORMATION ONLY. This is not a Solicitation Announcement, nor is it a Request for Proposal. This request does not obligate the Government in any contract award. The USAHCA � Medical Readiness Contracting Office Europe-USAHCA-MRCO-EUR is issuing the sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support the requirement for Gas Chromatograph with Dual Electron Capture Detector. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 339112 (Surgical and Medical Instrument Manufacturing) with business size standard 1,000 Employees. PSC code is 6630 � Chemical Analysis Instruments. The anticipated delivery 45 days after contract award. The delivery address: Regional Landstuhl Medical Center Landstuhl, Germany S ALIENT CHARACTERISTICS Brand Name or Equal � Gas Chromatograph with dual Electron Capture Detector (GC-?ECD) and dual liquid autosamplers with the ability to screen drinking water and food samples for a wide array of prominent and emergent organic pollutants simultaneously. o Operation Workstation must be included with the equipment. o Data acquisition and processing software to control instrument and process data must be included. o System must run all software on Windows 11. o System must have two split/split less injection ports. o System must have two Electron Capture Detectors with EPCs. o The instrument must have capability for simultaneous and independent detection of each ECD. o Equipment must be able to operate on 230V/50 Hz. � Two liquid autosamplers must be included with the equipment, including a tray for samples. o Auto-sampler tray with capacity of at least 150 samples and ability to cool samples ?6C. o Instrument must include two autosamplers with the capability for simultaneous dual column injection onto two inlets. � The GC system must have an integrated compartment with capability for at least 2 columns with quick-connect fittings for facile switching between methods. � The instrument must have capability for simultaneous and independent detection of each ECD. � The system should come equipped with all necessary consumables to run methods EPA 505, 504.1, 515.4 and 553.2 (Split less liners, Dissimilar Pesticide columns, ferrules, seals, etc.) � The system must come with a minimum of a one-year warranty. � The system must come with operation and troubleshooting manuals. � Instrument must be installed by a qualified service representative and properly verified for use. If you are interested in participating in this requirement and/or your organization has the potential capacity to perform these services, please submit the following to the Point of Contacts (POC) information listed below: 1. Name and Address of your Firm 2. Point of Contact (name/phone/email) 3. Company website 4. Unique Entity identifier (UEI) number 5. Commercial and Government Entity (CAGE) code 6. Capability statement -
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/73114fdc98b142efbb8939f5409d7506/view)
 
Place of Performance
Address: DE-RP 09180, DEU
Zip Code: 09180
Country: DEU
 
Record
SN07521887-F 20250725/250723230055 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.