Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 14,2000 PSA#2621

Department of the Air Force, Air Mobility Command, 89th CONS, 1419 Menoher Drive, Andrews AFB, MD, 20762-6500

N -- CONNECTION OF GENERATOR SOL FA4416-00-Q0032 DUE 062100 POC Jim Harris, Contract Specialist, Phone 301-981-1951, Fax 301-981-1907, Email Jim.Harris@Andrews.af.mil WEB: Visit this URL for the latest information about this, http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=FA4416-00-Q00 32&LocID=250. E-MAIL: Jim Harris, Jim.Harris@Andrews.af.mil. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Solicitation Number FA4416-00-Q0032 is issued as a Request for Quotation (RFQ). This solicitation document and incorporated provisions are those in effect through Federal Acquisition Circular 97-17. This is a 100% small business set aside. The SIC code is 1731. The size standard is $7.0. The contractor shall provide the following: Item 0001: search and inspect the existing panelboard feeding Room A306, Bldg 1535, and ensure all circuits are identified before disconnection; Item 0002: Disconnect all circuits from existing panelboard feeding Room A306 and connect these circuits to the new panelboard; Item 0003: Provide one panelboard (10,000AIC) with 100A main circuit breaker, 120/208V, 3phase, and 4w with 12 circuit breakers, 20A each. From the Automatic Transfer Switch (located in the generator room) connect and use four #1/0 AWG in 1.5_ conduit (approximately 200 ft) to new panelboard (to be installed near or in Room A306). Item 0004: Provide a surge suppressor for the new panelboard, 120/208V, 3 phase, and 4W (15,000A-surge capacity). Surge suppressor shall be installed before the main circuit breaker of the new panelboard; Item 0005: Provide one 80A, 240V, 3 pole circuit breaker with enclosure to be connected from generator to automatic transfer switch. Connect and use four #2 in 1.25_ conduit (approximately 50 ft). The provision at FAR 52.212-1, " Instructions to Offerors-Commercial Items and addenda's. FAR 52.237.1 Site Visit and FAR 52.228-5 Insurance -- Work on a Government Installation, is applicable to this acquisition. The provision FAR 52-212-2 Evaluation -- Commercial Items is applicable to the solicitation and the blanks in (a) are completed as follows: Price and Past Performance.Offerors shall include with their offers, a completed copy of 52.212-3, Offeror Representations and Certifications -- Commercial Items; FAR clause 52.212-4, Contract Terms and Conditions Commercial Items is applicable to this solicitation. FAR clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items is applicable and the following clauses are checked: 52.232.33, Payment by Electronic Funds Transfer-Central Contractor Registration and 52.222-41 Service Contract Act of 1965, as amended (41 U.S.C. 351, et seq.). DFARs clause 252.204-7004 Required Central Contractor Registration is applicable to the solicitation. The full text of these clauses may be accessed electronically at this address: http:// FARSIT.HILL.AF.MIL.VFFARA.HTRM. A site visit will be held on 16 Jun 2000 at 10:00 AM Eastern Time. Attendees shall meet at Bldg 1840, Main Gate Visitor Center, Andrews Air Force Base MD and should contact the contract specialist below by 14 Jun 2000 before 3:30 PM Eastern Standard Time to be granted access to the base. Responses to this RFQ must be received via fax, mail or delivery by 21 Jun 2000 no later than 4:00 PM Eastern Standard Time at the 89th Contracting Squadron, 1419 Menoher Drive, Andrews AFB Maryland. They should be marked with solicitation number and addressed to Jim Harris. Vendors not registered in the Central Contractor Registration (CCR) database, prior to award will be ineligible for award. Vendors may register for CCR by calling 1-800-334-3414 or register on line at www.CCR2000.com. Contractors are requested to review the Statement of Work posted as DRAFT on EPS (Electronic Posting System). Contractors are required to check the following internet site regularly for amendments: www.eps.gov, USAF- Air Mobility Command- Andrews. For questions concerning this solicitation, contact Jim Harris, Contract Specialist, at (301) 981-1951, Fax (301) 981-1907 or via email jim.harris@andrews.af.mil. Posted 06/10/00 (D-SN463523). (0162)

Loren Data Corp. http://www.ld.com (SYN# 0060 20000614\N-0002.SOL)


N - Installation of Equipment Index Page